Related papers: Neutron spectrometer for fast nuclear reactors
A time-of-flight spectrometer of neutrons in the energy range (0.05 -- 2.5)$\mu$eV is described. This spectrometer has been tested my measuring the total and differential neutron cross sections for a number of materials: Al, Cu, $^{6}$LiF,…
An experiment with a newly developed high-resolution kaon spectrometer (HKS) and a scattered electron spectrometer with a novel configuration was performed in Hall C at Jefferson Lab (JLab). The ground state of a neutron-rich hypernucleus,…
We have developed a neutrino detector with threshold energies from ~0.115 to 105 MeV in a clean detection mode almost completely void of accidental backgrounds. It was initially developed for the NASA $\nu$SOL project to put a solar…
We introduce the LUNA neutron detector array developed for the investigation of the 13C(a,n)16O reaction towards its astrophysical s-process Gamow peak in the low-background environment of the Laboratori Nazionali del Gran Sasso (LNGS).…
The neutron energy spectrum for energies between 5 and 15 MeV has been measured in the INFN Laboratori Nazionali del Gran Sasso in Italy, by using a $1.5~m^3$ stainless-steel tank filled with 1.2 ton Gd-doped liquid scintillator. A…
We present a laser-based neutron source that produces $1.8 \times 10^5$ neutrons/s with a conversion rate of $7.8 \times 10^5$ neutrons/J. Laser pulses of 12 fs and 23 mJ were focused onto a 430-nm-thick heavy water liquid sheet at a 10 Hz…
We report on the experimental observation of beam-like neutron emission with peak flux of the order of 10^9 n/sr, from light nuclei reactions in a pitcher-catcher scenario, by employing MeV ions driven by high power laser. The spatial…
One of the main sources of a background in underground physics experiments (such as the investigation of solar neutrino flux, neutrino oscillations, neutrinoless double beta decay, and the search for annual and daily Cold Dark Matter…
The work is devoted to development of hard electron antineutrino source with variable and regulated (controlled) spectrum. The high flux antineutrino source with hard antineutrino spectrum based on neutron activation of 7Li and subsequent…
The worldwide need to replace 3He for the neutron detection has triggered R&D on new technologies and methods. A promising one is based on commercial solid state silicon detectors coupled with thin neutron converter layers containing 6Li.…
A new neutron detector based on Micromegas technology has been developed for the measurement of the simulated neutron spectrum in the ADS project. After the presentation of simulated neutron spectra obtained in the interaction of 140 MeV…
The measurement of environmental neutrons is particularly important in the search for new physics, such as dark matter particles, because neutrons constitute an often-irreducible background source. The measurement of the neutron energy…
A pixel detector with high spatial resolution and temporal information for ultra-cold neutrons is developed based on a commercial CCD on which a neutron converter is attached. 10B and 6Li are tested for the neutron converter and 10B is…
Two-dimensional solid state gaseous detector for thermal and cold neutrons is created. The detector has active area of 128 x 128 $mm^2$, $^{10}B$ neutron converter, and gas chamber with thin windows. The resistive charge-division readout is…
A large area (0.5~m $\times$ 0.5~m) thermal neutron detector was developed based on 0.32~mm-thick $^{6}$LiF:ZnS(Ag) scintillator sheets. The detector was constructed for measurements of seasonal variations in low intensity thermal neutron…
The neutron emission in the fragmentation of stable and radioactive Sn and La projectiles of 600 MeV per nucleon has been studied with the Large Neutron Detector LAND coupled to the ALADIN forward spectrometer at SIS. A cluster-recognition…
A compact liquid organic neutron spectrometer (CLONS) based on a single NE213 liquid scintillator (5 cm diam. x 5 cm) is described. The spectrometer is designed to measure neutron fluence spectra over the energy range 2-200 MeV and is…
Two detection systems based on optical readout were developed: a. Integrative optical detector A 2nd generation of Time-Resolved Integrative Optical Neutron (TRION) detector was developed. It is based on an integrative optical technique,…
Energy-resolved neutron imaging at a pulsed source utilizes the energy-dependent neutron transmission measured via time-of-flight to extract quantitative information about the internal microstructure of an object. At the RADEN instrument at…
The Helium-3 shortage and the growing interest in neutron science constitute a driving factor in developing new neutron detection technologies. In this work, we report the development of a double-GEM detector prototype that uses a…