English
Related papers

Related papers: 1 {\Omega}-10 k{\Omega} high precision transportab…

200 papers

At National Institute of Metrological Research (INRIM), an automated setup to calibrate DC Voltage generators, mainly top-level calibrators from 1 mV to 1 kV has been developed. The heart of the setup is an INRIM-built automated fixed…

Instrumentation and Detectors · Physics 2017-08-31 Flavio Galliana , Pier Paolo Capra , Roberto Cerri , Marco Lanzillotti

An automated temperature-controlled electrical DC voltage and DC resistance multiple reference standard (MRS) has been developed by Measurements International (MI) with the scientific support from the Istituto Nazionale di Ricerca…

Instrumentation and Detectors · Physics 2025-01-22 F. Gallianaa , P. Capra , R. Cerri , C. Francese , M. Lanzillotti L. Roncaglione Tet , F. Pennecchi , A. Pollarolo

At National Institute of Metrological Research (INRIM), a selectable-value Transportable High dcVoltage Standard (THVS) operating in the range from 10 V to 100 V in steps of 10 V, was developed. This Standard was built to cover the lack of…

Instrumentation and Detectors · Physics 2016-05-17 Flavio Galliana , Roberto Cerri , Luca Roncaglione Tet

A novel approach to calibrate the sensitivity of a differential thermometer, consisting of several thermocouples connected in series (thermopile), has been developed. The goal of this method is to increase the accuracy of small temperature…

Instrumentation and Detectors · Physics 2020-12-24 Tim Prangemeier , Iman Nejati , Andreas Müller , Philip Endres , Mario Fratzl , Mathias Dietzel

A flat mounting unit with electronically variable thermal resistance [1] has been presented in the last year [2]. The design was based on a Peltier cell and the appropriate control electronics and software. The device is devoted especially…

General Physics · Physics 2008-01-08 V. Szekely , S. Torok , E. Kollar

We have designed and developed a new experimental setup, based on the 3-omega method, to measure thermal conductivity, heat capacity and electrical resistivity of a variety of samples in a broad temperature range (2-550 K) and under…

Instrumentation and Detectors · Physics 2018-04-17 K. Shrestha , K. Gofryk

An accurate and extensive Inter-laboratory comparison between the laboratory for the calibration of multifunction electrical instruments of the National Institute of Metrology Research (INRIM) and a secondary high level electrical…

Instrumentation and Detectors · Physics 2016-04-22 F. Galliana , M. Lanzillotti

A simple and low cost apparatus has been designed and built to measure the electrical resistivity, ($\rho$), of metal and semiconductors in 300-620 K temperature range. The present design is suitable to do measurement on rectangular bar…

General Physics · Physics 2017-04-14 Saurabh Singh , Sudhir K. Pandey

This paper describes the developed setup and characterization approach for full two-port calibrated S-parameter measurements at cryogenic temperatures, together with a complete uncertainty budget. The system developed at the Istituto…

A prototype device capable of moving a radioactive calibration source to multiple positions was operated at millikelvin temperatures using a modified commercial stepper motor. It was developed as an in-situ calibration strategy for…

Instrumentation and Detectors · Physics 2020-05-06 N. Mast , M. Fritts , D. Sincavage , P. Cushman , V. Mandic

We report on experiments performed in vacuum and at cryogenic temperatures on a tri-port nano-electro-mechanical (NEMS) device. One port is a very non-linear capacitive actuation, while the two others implement the magnetomotive scheme with…

Mesoscale and Nanoscale Physics · Physics 2015-12-02 E. Collin , M. Defoort , K. Lulla , T. Moutonet , J. -S. Heron , O. Bourgeois , Yu. M. Bunkov , H. Godfrin

We report on the realization of a high sensitivity RF noise measurement scheme to study small current fluctuations of mesoscopic systems at milliKelvin temperatures. The setup relies on the combination of an interferometric ampli- fication…

Mesoscale and Nanoscale Physics · Physics 2011-03-07 François D. Parmentier , Adrien Mahé , Anne Denis , Jean-Marc Berroir , D. Christian Glattli , Bernard Plaçais , Gwendal Fève

The design, manufacture and characterisation of an inexpensive, temperature controlled vacuum chamber with millikelvin stability for electrical transport measurements at and near room temperature is reported. A commercially available…

Instrumentation and Detectors · Physics 2024-03-07 S. F. Poole , O. J. Amin , A. Solomon , L. X. Barton , R. P. Campion K. W. Edmonds , P. Wadley

This is the report on new development of an automated precision load-based measurement setup for thermoelectric power of different types of samples in the temperature range 5 - 330 K. The problems in the old spring-based setup have been…

Applied Physics · Physics 2019-03-12 Tarachand , Monika Saxena , Bodhoday Mukherjee , Gunadhor S. Okram

We review the status of the understanding of single-electron transport (SET) devices with respect to their applicability in metrology. Their envisioned role as the basis of a high-precision electrical standard is outlined and is discussed…

Mesoscale and Nanoscale Physics · Physics 2015-06-25 Karsten Flensberg , Arkadi A. Odintsov , Feike Liefrink , Paul Teunissen

We describe a calibration setup for the transresistance of low-current amplifiers, based on the capacitance-charging method. The calibration can be performed in the current range of typical interest for electron counting experiments. The…

Instrumentation and Detectors · Physics 2016-10-18 Ilaria Finardi , Luca Callegaro

We report on the design, fabrication, and implementation of ultrasensitive micromechanical oscillators. Our ultrathin single-crystal silicon cantilevers with integrated magnetic structures are the first of their kind: They are fabricated…

Mesoscale and Nanoscale Physics · Physics 2007-05-23 Michelle D. Chabot , John M. Moreland , Lan Gao , Sy-Hwang Liou , Casey W. Miller

We present a one-heater-two-thermometer set-up for measuring thermal conductivity and electric resistivity of a bulk sample at low temperatures down to 0.1 K and in magnetic fields up to 27 Tesla. The design overcomes the difficulties…

Superconductivity · Physics 2009-11-10 P. J. E. M. van der Linden , K. Behnia

A class of Actively Calibrated Line Mounted Capacitive Voltage Transducers (LMCVT) are introduced as a viable line mountable instrumentation option for deploying large numbers of voltage transducers onto the medium and high voltage systems.…

Instrumentation and Detectors · Physics 2017-01-27 Raffi Sevlian , Ram Rajagopal

This research provides the theoretical feasibility study of a novel architecture of a MEMS differential resonant accelerometer, with switchable and tunable electrostatic transmission between the proof mass and the vibrating sensing beams.…

Signal Processing · Electrical Eng. & Systems 2025-07-25 Alexandra Zobova , Slava Krylov
‹ Prev 1 2 3 10 Next ›