Related papers: A D-bar Algorithm with A Priori Information for El…
The aim of this paper is to show the feasibility of the D-bar method for real-time 2-D EIT reconstructions. A fast implementation of the D-bar method for reconstructing conductivity changes on a 2-D chest-shaped domain is described.…
Electrical Impedance Tomography (EIT) aims to recover the internal conductivity and permittivity distributions of a body from electrical measurements taken on electrodes on the surface of the body. The reconstruction task is a severely…
The aim of electrical impedance tomography is to form an image of the conductivity distribution inside an unknown body using electric boundary measurements. The computation of the image from measurement data is a non-linear ill-posed…
In Electrical Impedance Tomography (EIT), the internal conductivity of a body is recovered via current and voltage measurements taken at its surface. The reconstruction task is a highly ill-posed nonlinear inverse problem, which is very…
In electrical impedance tomography the electrical conductivity inside a physical body is computed from electro-static boundary measurements. The focus of this paper is to extend recent result for the 2D problem to 3D. Prior information…
We present a few ways of using conformal maps in the reconstruction of two-dimensional conductivities in electrical impedance tomography. First, by utilizing the Riemann mapping theorem, we can transform any simply connected domain of…
The D-bar method at negative energy is numerically implemented. Using the method we are able to numerically reconstruct potentials and investigate exceptional points at negative energy. Subsequently, applying the method to Diffusive Optical…
The regularized D-bar method is a popular method for solving Electrical Impedance Tomography (EIT) problems due to its efficiency and simplicity. It utilizes the low-pass truncated scattering data in the non-linear Fourier domain to solve…
The first numerical implementation of a D-bar method in 3D using electrode data is presented. Results are compared to Calder\'on's method as well as more common TV and smoothness regularization-based methods. D-bar methods are based on…
Objective: Absolute images have important applications in medical Electrical Impedance Tomography (EIT) imaging, but the traditional minimization and statistical based computations are very sensitive to modeling errors and noise. In this…
Electrical impedance tomography is an imaging modality for extracting information on the conductivity distribution inside a physical body from boundary measurements of current and voltage. In many practical applications, it is a priori…
This work considers finding optimal positions for the electrodes within the Bayesian paradigm based on available prior information on the conductivity; the aim is to place the electrodes so that the posterior density of the (discretized)…
Recent advances in deep learning have led to a data-centric intelligence i.e. artificially intelligent models unlocking the potential to ingest a large amount of data and be really good at performing digital tasks such as text-to-image…
The objective of electrical impedance tomography is to reconstruct the internal conductivity of a physical body based on measurements of current and potential at a finite number of electrodes attached to its boundary. Although the…
This paper focuses on prior information for improved sparsity reconstruction in electrical impedance tomography with partial data, i.e. data measured only on subsets of the boundary. Sparsity is enforced using an $\ell_1$ norm of the basis…
A new computational method for reconstructing a potential from the Dirichlet-to-Neumann map at positive energy is developed. The method is based on D-bar techniques and it works in absence of exceptional points -- in particular, if the…
A novel computational, non-iterative and noise-robust reconstruction method is introduced for the planar anisotropic inverse conductivity problem. The method is based on bypassing the unstable step of the reconstruction of the values of the…
Electrical impedance tomography (EIT) is a non-invasive imaging method in which an unknown physical body is probed with electric currents applied on the boundary, and the internal conductivity distribution is recovered from the measured…
The performance of the state-of-the-art image segmentation methods heavily relies on the high-quality annotations, which are not easily affordable, particularly for medical data. To alleviate this limitation, in this study, we propose a…
Variational segmentation algorithms require a prior imposed in the form of a regularisation term to enforce smoothness of the solution. Recently, it was shown in the Deep Image Prior work that the explicit regularisation in a model can be…