English
Related papers

Related papers: Evaluation of new large area PMT with high quantum…

200 papers

In the upcoming IceCube-Gen2 extension, the newly developed optical modules will include 4-inch PMTs. For this purpose, the manufacturers Hamamatsu and North Night Vision Technology have developed new PMT models to meet the requirements of…

Instrumentation and Methods for Astrophysics · Physics 2023-07-28 Markus Dittmer , Alexander Kappes

A UV laser calibration system is developed for the Jiangmen Underground Neutrino Observatory (JUNO), a 20-kton liquid scintillator-based, long baseline reactor anti-neutrino experiment. This system is capable of delivering fast laser pulses…

Instrumentation and Detectors · Physics 2019-01-30 Yuanyuan Zhang , Jianglai Liu , Mengjiao Xiao , Feiyang Zhang , Tao Zhang

Dark noise is a dominant background in photomultiplier tubes (PMTs), which are commonly used in liquid-filled particle detectors for single-photon detection to see the results of particle interactions. A major contribution to dark noise is…

Instrumentation and Detectors · Physics 2023-11-28 Steve T. Wilson , Samuel Fargher , Robert J. Foster , Matthew Malek , Matthew Needham , Andrew Scarff , Gary D. Smith

The model R5912-20MOD photomultiplier tube(PMT) is made for cryogenic application by Hamamatsu. In this paper, we report on the measurement of relative quantum efficiency (QE) of this model PMT at liquid argon(LAr) temperature. Furthermore,…

Instrumentation and Detectors · Physics 2021-07-13 Qin Zhao , Mengyun Guan , Peng Zhang , Changgen Yang , Jiajun Li , Yuting Wei , Lei Wang , Youyu Gan , Weixing Xiong

The medium baseline reactor antineutrino experiment, Jiangmen Underground Neutrino Observatory (JUNO), which is being planed to be built at Jiangmen in South China, can determine the neutrino mass hierarchy and improve the precision of…

Instrumentation and Detectors · Physics 2015-06-18 Yu-Feng Li

The Hamamatsu R5912-02Mod photomultiplier tube (PMT) will be used in the DUNE dual-phase module, a 10-kton fiducial volume liquid-argon time-projection chamber, which is one of the four projected far-detector modules of the DUNE…

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and…

High Energy Physics - Experiment · Physics 2024-08-19 T. Contreras , B. Palmeiro , H. Almazán , A. Para , G. Martínez-Lema , R. Guenette , C. Adams , V. Álvarez , B. Aparicio , A. I. Aranburu , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , C. D. R. Azevedo , K. Bailey , F. Ballester , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , A. Brodolin , N. Byrnes , S. Cárcel , A. Castillo , S. Cebrián , E. Church , L. Cid , C. A. N. Conde , F. P. Cossío , E. Dey , G. Díaz , T. Dickel , C. Echevarria , M. Elorza , J. Escada , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , A. L. Ferreira , F. W. Foss , Z. Freixa , J. García-Barrena , J. J. Gómez-Cadenas , R. González , J. W. R. Grocott , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , Y. Ifergan , B. J. P. Jones , F. Kellerer , L. Larizgoitia , A. Larumbe , P. Lebrun , F. Lopez , N. López-March , R. Madigan , R. D. P. Mano , A. P. Marques , J. Martín-Albo , M. Martínez-Vara , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , K. E. Navarro , P. Novella , A. Nuñez , D. R. Nygren , E. Oblak , J. Palacio , I. Parmaksiz , A. Pazos , J. Pelegrin , M. Pérez Maneiro , M. Querol , A. B. Redwine , J. Renner , I. Rivilla , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , F. P. Santos , J. M. F. dos Santos , M. Seemann , I. Shomroni , P. A. O. C. Silva , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , S. Teruel-Pardo , J. F. Toledo , C. Tonnelé , J. Torrent , A. Trettin , A. Usón , P. R. G. Valle , J. F. C. A. Veloso , J. Waiton , A. Yubero-Navarro

In the Energy Frontier we suggest developing high rate (100 MHz) finely segmented forward calorimetry preradiators with time resolution <50 ps which will survive the first 1-2 Lint of incident high radiation doses, protecting forward…

Instrumentation and Detectors · Physics 2022-03-21 David R Winn , Yasar Onel

Modern neutrino physics detectors often employ thousands, and sometimes even hundreds of thousands, of Silicon Photomultipliers (SiPMs). The TAO experiment is a notable example that utilizes a spherical scintillator barrel with a diameter…

Instrumentation and Detectors · Physics 2024-02-09 A. Rybnikov , N. Anfimov , M. Qu , A. Chetverikov , G. Cao , D. Fedoseev , H. Wang , V. Kozhukalov , V. Sharov , S. Sokolov , A. Sotnikov

The China Jinping underground Laboratory (CJPL) is an excellent location for studying solar, terrestrial, and supernova neutrinos due to its 2400-meter vertical rock overburden. Its unparalleled depth gives an opportunity to investigate the…

The Jiangmen Underground Neutrino Observatory (JUNO) is an experiment proposed to determine the neutrino mass hierarchy and probe the fundamental properties of neutrino oscillation. The JUNO central detector is a spherical liquid…

Instrumentation and Detectors · Physics 2015-12-15 Xinying Li , Ziyan Deng , Liangjian Wen , Weidong Li , Zhengyun You , Chunxu Yu , Yumei Zhang , Tao Lin

The Hamamatsu R11410-21 photomultiplier tube is the photodetector of choice for the XENON1T dual-phase time projection chamber. The device has been optimized for a very low intrinsic radioactivity, a high quantum efficiency and a high…

Instrumentation and Methods for Astrophysics · Physics 2017-03-08 P. Barrow , L. Baudis , D. Cichon , M. Danisch , D. Franco , F. Kaether , A. Kish , M. Lindner , T. Marrodan Undagoitia , D. Mayani , L. Rauch , Y. Wei , J. Wulf

Observation of supernovae (SN) through their neutrino emission is a fundamental point to understand both SN dynamics and neutrino physical properties. JUNO is a 20kton liquid scintillator detector, under construction in Jiangmen, China. The…

High Energy Astrophysical Phenomena · Physics 2019-10-09 C. Martellini , S. M. Mari , P. Montini , G. Settanta

The NeuLAND (New Large-Area Neutron Detector) plastic-scintillator-based time-of-flight detector for 0.1-1.6 GeV neutrons is currently under construction at the Facility for Antiproton and Ion Research (FAIR), Darmstadt, Germany. In its…

Instrumentation and Detectors · Physics 2023-01-11 Thomas Hensel , David Weinberger , Daniel Bemmerer , Konstanze Boretzky , Igor Gašparić , Daniel Stach , Andreas Wagner , Kai Zuber

Detailed Monte-Carlo simulations were used to evaluate the performance of a liquid neon scintillation detector for dark matter and low-energy solar neutrino interactions. A maximum-likelihood event vertex fitter including PMT time…

Nuclear Experiment · Physics 2007-05-23 M. G. Boulay , A. Hime , J. Lidgard

We present Monte Carlo (MC) simulation results from a study of a compact plastic-scintillator detector suitable for imaging fast neutrons in the 1 -- 10 MeV energy range: the miniTimeCube (mTC). Originally designed for antineutrino…

The Taishan Antineutrino Observatory (TAO) is a liquid-scintillator satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO) to measure the reference reactor neutrino spectrum with unprecented energy resolution. We use…

High Energy Physics - Experiment · Physics 2025-04-22 Xuewei Liu , Wei Dou , Benda Xu , Hanwen Wang , Guofu Cao

It is critical to construct an accurate optical model of photomultiplier tubes (PMTs) in many applications to describe the angular and spectral responses of the photon detection efficiency (PDE) of the PMTs in their working media. In this…

Instrumentation and Detectors · Physics 2022-04-19 Yaoguang Wang , Guofu Cao , Liangjian Wen , Yifang Wang

Measuring the neutrino mixing parameter \ensuremath{\sin^2\theta_{13}} to the sub-percent precision level could be necessary in the next ten years for the precision unitary test of the PMNS matrix. In this work, we discuss the possibility…

High Energy Physics - Experiment · Physics 2023-03-17 Jinnan Zhang , Jun Cao

UV-glass photomultiplier tubes (PMTs) have poor photon detection efficiency for wavelengths below $300\,\text{nm}$ due to the opaqueness of the window material. Costly quartz PMTs could be used to enhance the efficiency below…

Instrumentation and Detectors · Physics 2018-03-14 S. Joosten , E. Kaczanowicz , M. Ungaro , M. Rehfuss , K. Johnston , Z. -E. Meziani