Related papers: Evaluation of new large area PMT with high quantum…
This paper describes the performance and sensitivity to neutrino mixing parameters of a Magnetised Iron Neutrino Detector (MIND) at a Neutrino Factory with a neutrino beam created from the decay of 10 GeV muons. Specifically, it is…
The H12700 is a novel 64-channel 52 $\times$ 52 mm$^2$ square Multi-Anode PhotoMultiplier Tube (MaPMT) produced by Hamamatsu. Its characteristics make this device suitable for high energy physics applications, such as in Ring Imaging…
The Jiangmen Underground Neutrino Observatory (JUNO), a 20ktons multi-purpose underground liquid scintillator detector, was proposed with the determination of the neutrino mass hierarchy as a primary physics goal. Due to low background…
The Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton multi-purpose low background liquid scintillator detector, was proposed primarily to determine the neutrino mass ordering. To mitigate radioactivity from surrounding rock and…
The Jiangmen Underground Neutrino Observatory (JUNO) is a multipurpose neutrino experiment with a 20 kt liquid scintillator detector designed to determine the neutrino mass hierarchy, and measure the neutrino oscillation parameters. Linear…
Energy-resolved neutron imaging at a pulsed source utilizes the energy-dependent neutron transmission measured via time-of-flight to extract quantitative information about the internal microstructure of an object. At the RADEN instrument at…
A special type of Hamamatsu MPPC, with a sensitive area of 1.3x1.3mm^2 containing 667 pixels with 50x50um^2 each, has been developed for the near neutrino detector in the T2K long baseline neutrino experiment. About 60 000 MPPCs will be…
The increasing complexity of the recent photonic experiments challenges developing efficient multi-channel coincidence counting systems with high-level functionality. Here, we report a coincidence unit able to count detection events ranging…
To fulfill the requirements for testing the photomultiplier tubes (PMTs) of the electromagnetic detec- tor at the Large High Altitude Air Shower Observatory (LHAASO), a multi-functional PMT test bench with a two dimensional scanning system…
Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be…
Following the first observation of an astrophysical high-energy neutrino flux with the IceCube Neutrino Observatory in 2013 and the identification of a first cosmic high-energy neutrino source in 2017, the detector will be upgraded with…
We take the JUNO experiment as an example to explore nuclearites in the future large liquid scintillator detector. Comparing to the previous calculations, the visible energy of nuclearites across the liquid scintillator will be reestimated…
Aside from its primary purpose of shedding light on the mass hierarchy (MH) using reactor anti-neutrinos, the JUNO experiment in Jiangmen (China) will also contribute to study neutrinos from non-reactor sources. In this poster we review…
To study the dependence of the equation of state of high density nuclear matter on the term characterizing the isospin (proton-neutron) asymmetry of nuclear matter, it is necessary to measure azimuthal flow of neutrons as well as azimuthal…
The optical module of the KM3NeT neutrino telescope is an innovative, multi-faceted large area photodetection module. It contains 31 three-inch photomultiplier tubes in a single 0.44 m diameter pressure-resistant glass sphere. The module is…
We report on the measurements of the absolute Quantum Efficiency(QE) for Hamamatsu model R11410-10 PMTs specially designed for the use in low background liquid xenon detectors. QE was measured for five PMTs in a spectral range between 154.5…
The T2K collaboration reports a precision measurement of muon neutrino disappearance with an off-axis neutrino beam with a peak energy of 0.6 GeV. Near detector measurements are used to constrain the neutrino flux and cross section…
In this paper we stress the idea that new, more precise neutrino cross-sections measurements at low energies will be necessary to improve the results of future big neutrino detectors, which will be dominated by the contribution of the…
This paper describes the electronics of NEXT-White (NEW) detector PMT plane, a high pressure xenon TPC with electroluminescent amplification (HPXe-EL) currently operating at the Laboratorio Subterra\'aneo de Canfranc (LSC) in Huesca, Spain.…
Results of radiation tests of Hamamatsu 2.0 x 2.0~mm2 through-silicon-via (S13360-2050VE) multi-pixel photon counters, or MPPCs [1], are presented. Distinct sets of eight MPPCs were exposed to four different 1~MeV neutron equivalent doses…