Related papers: Soft X-ray Angle Resolved Photoemission with Micro…
A synchrotron radiation beamline in the photon energy range of 18 - 240 eV and an electron spectroscopy end station have been constructed at the 3 GeV Diamond Light Source storage ring. The instrument features a variable polarisation…
Decades of astrophysical observations have convincingly shown that soft X-ray (SXR; ~0.1--10 keV) emission provides unique diagnostics for the high temperature plasmas observed in solar flares and active regions. SXR observations critical…
We investigate the electronic structure of $2H$-$\mathrm{Nb}\mathrm{S}_2$ and $h$-$\mathrm{BN}$ by angle-resolved photoemission spectroscopy (ARPES) and photoemission intensity calculations. Although in bulk form, these materials are…
Spectrographs take snapshots of photon spectra with array detectors by dispersing photons of different energies into distinct directions and spacial locations. Spectrographs require optics with a large angular dispersion rate as the key…
Electron emission can be utilised to measure the work function of the surface. However, the number of significant digits in the values obtained through thermionic-, field- and photo-emission techniques is typically just two or three. Here,…
We present the results of a Suzaku spectroscopic study of the soft extended X-ray emission in the HII region M17. The spectrum of the extended emission was obtained with a high signal-to-noise ratio in a spatially-resolved manner using the…
Although negative-refractive-index metamaterials have successfully achieved subwavelength focusing, image resolution is limited by the presence of losses. In this Letter, a metal transmission screen with subwavelength spaced slots is…
A scheme of soft-xray radiation is proposed. In the scheme, a moderately intense laser excites plasmons via the two-plasmon decay in a relativistic electron beam. As the second laser encounters the electron beam in the opposite direction,…
Understanding the mechanisms underlying a stable polarization at the surface of ferroelectric thin films is of particular importance both from a fundamental point of view and to achieve control of the surface polarization itself. In this…
X-ray standing wave (XSW) excited photoelectron emission was used to measure the site-specific valence band (VB) for 1/2 monolayer (ML) Pt grown on a SrTiO3 (001) surface. The XSW induced modulations in the core level (CL) and VB…
Polarization-controlled synchrotron radiation was used to map the electronic structure of buried conducting interfaces of LaAlO$_3$/SrTiO$_3$ in a resonant angle-resolved photoemission experiment. A strong dependence on the light…
Angle-resolved photoemission spectroscopy (ARPES) is the key momentum-resolved technique for direct probing of the electronic structure of a material. However, since it is very surface-sensitive, it has been applied to a relatively small…
For many applications of extreme ultraviolet (XUV) and x-ray pulses a small focus size is crucial to reach the required intensity or spatial resolution. In this article, we present a simple way to characterize an XUV focus with a resolution…
Soft X-ray resonant powder diffraction has been performed at the Mn L2,3 edges of A-site ordered SmBaMn2O6. The energy and polarization dependence of the (1/2 1/2 0) reflection provide direct evidence for a (x2-z2)/(y2-z2) type orbital…
The hard X-ray (HXR) emission in solar flares comes almost exclusively from a very small part of the flaring region, the footpoints of magnetic loops. Using RHESSI observations of solar flare footpoints, we determine the radial positions…
We have performed an angle-resolved photoemission study of the three-dimensional perovskite-type SrVO$_3$. Observed spectral weight distribution of the coherent part in the momentum space shows cylindrical Fermi surfaces consisting of the V…
We aim to study the temporal and spectral behaviour of four polar CVs from the infrared to X-ray regimes, refine our knowledge of the physical parameters of these systems at different accretion rates, and to search for a possible excess of…
Time-resolved x-ray magnetic circular dichroism (XMCD) enables a unique spectroscopic view on complex spin and charge dynamics in multi-elemental magnetic materials. So far, its application in the soft-x-ray range has been limited to…
Beam alignment enables efficient, stable transmission and control of optical energy and information, which critically depend on precise monitoring and regulation of the three-dimensional (3D) relative positioning between fibers. This study…
Spreading uniform and dense layers is of paramount importance to creating high-quality components using powder bed additive manufacturing (AM). Blade-like tools are often employed for spreading powder metal feedstocks, especially in laser…