Related papers: Microcalorimeter Spectroscopy at High Pulse Rates:…
X-ray absorption spectroscopy (XAS) is a powerful and well established technique with sensitivity to elemental and chemical composition. Despite these advantages, its implementation has not kept pace with the development of ultrafast pulsed…
This paper reports on the demonstration of a high-rate energy measurement technique using a thin depletion layer silicon avalanche photodiode (Si-APD). A dedicated amplitude-to-time converter is developed to realize simultaneous energy and…
For a high source activity experiment, such as HOLMES, non-constant baseline pulses could constitute a great fraction of the data-set. We test the optimal filter matrix technique, proposed to process these pulses, on simulated responses of…
Accurate and precise measurements of spectroradiometric temperature are crucial for many high pressure experiments that use diamond anvil cells or shock waves. In experiments with sub-millisecond timescales, specialized detectors such as…
Gigahertz (GHz) imaging using hard X-rays ($\gtrsim$ 10 keV) can be useful to high-temperature plasma experiments, as well as research using coherent photons from synchrotron radiation and X-ray free electron lasers. GHz framing rate can be…
Calorimetric decay energy spectroscopy of electron-capture-decaying isotopes is a promising method to achieve the sensitivity required for electron neutrino mass measurement. The very low total nuclear decay energy (QEC < 3 keV) and short…
We describe an instrument which can be used to analyze complex chemical mixtures at high resolution and high sensitivity. Molecules are collisionally cooled with helium gas at cryogenic temperatures (~ 4-7 K), and subsequently detected…
The proof test and debugging of the multi-pulsed electron accelerator, Dragon-2,requires a thorough comprehension of the quality of the beams. This puts forward a rigid requirement on the measurement system that it should have the ability…
Ultrashort, low-emittance electron pulses can be created at a high repetition rate by using a TM$_{110}$ deflection cavity to sweep a continuous beam across an aperture. These pulses can be used for time-resolved electron microscopy with…
Characterizing and controlling electronic properties of quantum materials require direct measurements of non-equilibrium electronic band structures over large regions of momentum space. Here, we demonstrate an experimental apparatus for…
We report measurements of the energy resolution of ultra-sensitive superconducting bolometric detectors. The device is a superconducting titanium nanobridge with niobium contacts. A fast microwave pulse is used to simulate a single…
Thermoelectric power sensors can now be used as transfer standards, instead of bolometers, in the microcalorimeter technique. This alternative has the technical advantages to be less sensitive to absolute temperature and not downward…
Large-mass bolometers are used in particle physics experiments to search for rare processes. The energy threshold of such detectors plays a critical role in their capability to search for dark matter interactions and rare nuclear decays. We…
The advent of back-illuminated complementary metal-oxide-semiconductor (CMOS) sensors and their well-known advantages over charge-coupled devices (CCDs) make them an attractive technology for future X-ray missions. However, numerous…
The combination of electronic sources operating at high frequencies and modern microwave instrumentation has enabled the recent development of chirped-pulse spectrometers for the millimetre and THz bands. This type of instrument can operate…
We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100 eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of $(60 \times 60)$ $\mu \text{m}^2$ and a…
Ultra-sensitive cryogenic calorimeters have become a favored technology with widespread application where eV-scale energy resolutions are needed. In this article, we characterize the performance of an X-ray magnetic microcalorimeter (MMC)…
We describe a high efficiency detector for measuring electron-positron pair transitions in nuclei. The device was built to be insensitive to gamma rays and to accommodate high overall event rates. The design was optimized for total pair…
We describe the design and measurement of feedhorn-coupled, transition-edge sensor (TES) polarimeters with two passbands centered at 220 GHz and 280 GHz, intended for observations of the cosmic microwave background. Each pixel couples…
Optical transition-edge sensors have shown energy resolution for resolving the number of incident photons at the telecommunication wavelength. Higher energy resolution is required for biological imaging and microscope spectroscopy. In this…