English
Related papers

Related papers: PMT signal increase using a wavelength shifting pa…

200 papers

UV-glass photomultiplier tubes (PMTs) have poor photon detection efficiency for wavelengths below $300\,\text{nm}$ due to the opaqueness of the window material. Costly quartz PMTs could be used to enhance the efficiency below…

Instrumentation and Detectors · Physics 2018-03-14 S. Joosten , E. Kaczanowicz , M. Ungaro , M. Rehfuss , K. Johnston , Z. -E. Meziani

Cherenkov detectors employ various methods to maximize light collection at the photomultiplier tubes (PMTs). These generally involve the use of highly reflective materials lining the interior of the detector, reflective materials around the…

Instrumentation and Detectors · Physics 2015-05-30 M. Sweany , A. Bernstein , S. Dazeley , J. Dunmore , J. Felde , R. Svoboda , M. Tripathi

Large-volume water-Cherenkov neutrino detectors are a light-starved environment, as each interaction produces only $\sim 50-100$ photons per MeV. As such, maximizing the light collection efficiency of the detector is vital to performance.…

Instrumentation and Detectors · Physics 2022-07-27 Austin Mullen , Oluwatomi Akindele , Marc Bergevin , Adam Bernstein , Steven Dazeley

The light yield of a water-based Cherenkov detector can be significantly improved by adding a wavelength shifter. Wavelength shifter (WLS) molecules absorb ultraviolet photons and re-emit them at longer wavelengths where typical…

Instrumentation and Detectors · Physics 2008-11-26 Xiongxin Dai , Etienne Rollin , Alain Bellerive , Cliff Hargrove , David Sinclair , Cathy Mifflin , Feng Zhang

The collection efficiency for Cherenkov light incident on a wavelength shifting plate (WLS) has been determined during a beam test at the Proton Synchrotron facility located in the National Laboratory for High Energy Physics (KEK), Tsukuba,…

The Wavelength-shifting Optical Module (WOM) is a novel photosensor concept for the instrumentation of large detector volumes with single-photon sensitivity. The key objective is to improve the signal-to-noise ratio which is achieved by…

Water Cherenkov detectors (WCDs) have been widely used in cosmic ray observations. This paper presents, for the first time, a cost-effective WCD design integrating a small photomultiplier tube (PMT) with wavelength-shifting fiber (WLS…

Instrumentation and Detectors · Physics 2025-02-26 H. Sun , Z. Huang , B. Wang , D. Liu , S. Ji , C. Feng

Silicon photomultipliers (SiPMs) have a few advantages over conventional photomultiplier tubes (PMTs) used in imaging atmospheric Cherenkov telescopes. The first notable characteristic is their higher photon detection efficiency (PDE) of up…

Instrumentation and Methods for Astrophysics · Physics 2023-09-19 Akira Okumura , Junya Haga , Chiaki Inoue , Keiji Nishimoto , Kazuhiro Furuta , Hiroyasu Tajima

Wavelength-shifting (WLS) materials contain molecules that absorb light and reemit at longer wavelengths. They can be used for light detection because they provide a large effective area for low cost and they are able to efficiently trap…

Instrumentation and Methods for Astrophysics · Physics 2023-09-27 M. Pihet , M. Mariotti , C. Arcaro

Improving the coincidence time resolution (CTR) of time-of-flight positron emission tomography (TOF-PET) systems to achieve a higher signal-to-noise ratio (SNR) gain or even direct positron emission imaging (dPEI) is of paramount importance…

Multiwalled carbon nanotubes (MWCNTs) are decorated with Pt nanoparticles by a "layer-by-layer" approach using poly (sodium 4-styrene sulfonate) (PSS) and poly (diallyl dimethylammonium chloride) (PDDA). Transmission electron microscopy…

Materials Science · Physics 2022-03-15 Samaneh Nasiri , Feng Shi , Guang Yang , Erdmann Spiecker , Qianqian Li

Currently the standard light sensors for imaging atmospheric Cherenkov telescopes are the classical photo multiplier tubes that are using bialkali photo cathodes. About eight years ago we initiated an improvement program with the Photo…

The XENON1T experiment is the most recent stage of the XENON Dark Matter Search, aiming for the direct detection of Weakly Interacting Massive Particles (WIMPs). To reach its projected sensitivity, the background has to be reduced by two…

Instrumentation and Detectors · Physics 2017-06-28 Christopher Geis , Cyril Grignon , Uwe Oberlack , Diego Ramírez García , Quirin Weitzel

Large-scale underground water-Cherenkov neutrino observatories rely on single photon sensors whose sensitive area for Cherenkov photons one wants to maximise. Low dark noise rates and dense module spacing will thereby allow to substantially…

Instrumentation and Methods for Astrophysics · Physics 2013-07-26 Lukas Schulte , Markus Voge , Akos Hoffmann , Sebastian Böser , Lutz Köpke , Marek Kowalski

The idea of implementing electroluminescence-based amplification through transparent multi-hole structures (FAT-GEMs) has been entertained for some time. Arguably, for such a technology to be attractive it should perform at least at a level…

The water Cherenkov detector array (WCDA) for the large high altitude air shower observatory(LHAASO) will employ more than 3600 hemisphere 8 inch photomultiplier tubes (PMT). The good time performance of PMT, especially the transit time…

Instrumentation and Detectors · Physics 2014-09-05 W. P. Huang , Z. B. Tang , C. Li , K. Jiang , X. K. Zhao

In this article, the potential of water Cherenkov detectors equipped with multi-PMT modules for background-free upward-going neutrino detection and improved direction reconstruction is demonstrated. By analyzing signal time traces with…

High Energy Physics - Experiment · Physics 2025-08-08 J. Alvarez-Muñiz , R. Colalillo , R. Conceição , B. S. González , V. M. Grieco , F. Guarino , M. Pimenta , B. Tomé , M. Waqas

Due to their very fast signal rise time in the order of 1 ns, Silicon-Photomultipliers have become of increasing interest for many experiments that require very good timing resolution. With the prospect of an application in medical imaging…

Instrumentation and Detectors · Physics 2019-05-01 Reimund Bayerlein , Ivor Fleck , Todd Peterson , Albert H. Walenta

To optimise the design of the light readout in the ArDM 1-ton liquid argon dark matter detector, a range of reflector and WLS coating combinations were investigated in several small setups, where argon scintillation light was generated by…

The use of silicon photomultipliers (SiPMs) alongside conventional photomultiplier tubes (PMTs) is a remarkable technological development in modern ground-based very high energy gamma-ray astronomy. SiPMs exhibit comparable or even higher…

Instrumentation and Methods for Astrophysics · Physics 2026-02-24 Razmik Mirzoyan , Alexander Hahn , David Fink , Antonios Dettlaff , Daniel Mazin , David Paneque , Olaf Reimann , Thomas Schweizer , Derek Strom , Masahiro Teshima , Yazhou Zhao
‹ Prev 1 2 3 10 Next ›