English
Related papers

Related papers: A Comprehensive Simulation Study of a Liquid-Xe De…

200 papers

The detection of photons above 10 keV through MeV and GeV energies is challenging due to the penetrating nature of the radiation, which can require large detector volumes, resulting in correspondingly high background. In this energy range,…

Instrumentation and Methods for Astrophysics · Physics 2010-10-21 David M. Smith

Spontaneous and induced fission in Special Nuclear Material (SNM) such as 235U and 239Pu results in the emission of neutrons and high energy gamma-rays. The multiplicities of and time correlations between these particles are both powerful…

Nuclear Experiment · Physics 2009-08-05 S. Dazeley , A. Bernstein , N. S. Bowden , R. Svoboda

We show that the sensitivity of antenna-coupled field-effect transistors (FETs) to terahertz (THz) radiation improves continuously with decreasing temperature. The noise-equivalent power (NEP) of 540 GHz patch-antenna-coupled FETs decreases…

In the near future there will be the request for very large liquid Xenon (LXe) detectors for Dark Matter (DM) searches in the 50-ton range. To avoid an impractically long, single drift space of a dual-phase detector, it seems beneficial to…

Instrumentation and Detectors · Physics 2021-09-01 P. Juyal , K. L. Giboni , X. Ji , J. Liu

XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground laboratory…

We have been developing a neutron detector with spatial resolution of submicron by loading 6Li into fine-grained nuclear emulsion. By exposure to thermal neutrons, tracks from neutron capture events were observed. From their grain density,…

Instrumentation and Detectors · Physics 2016-12-15 N. Naganawa , S. Awano , M. Hino , M. Hirose , K. Hirota , H. Kawahara , M. Kitaguchi , K. Mishima , T. Nagae , H. M. Shimizu , S. Tasaki , A. Umemoto

There has been an increasing interest in the monitoring of nuclear fuel for power reactors by detecting the anti-neutrinos produced during operation. Small liquid scintillator detectors have already demonstrated sensitivity to operational…

Instrumentation and Detectors · Physics 2007-05-23 R. W. McKeown , D. E. Reyna

Dual-phase xenon detectors are widely used in dark matter direct detection experiments, and have demonstrated the highest sensitivities to a variety of dark matter interactions. However, a key component of the dual-phase detector…

Instrumentation and Detectors · Physics 2019-06-05 Jingke Xu , Sergey Pereverzev , Brian Lenardo , James Kingston , Daniel Naim , Adam Bernstein , Kareem Kazkaz , Mani Tripathi

The study of transfer-induced gamma-decay probabilities is very useful for understanding the surrogate-reaction method and, more generally, for constraining statistical-model calculations. One of the main difficulties in the measurement of…

Instrumentation and Detectors · Physics 2016-06-09 Q. Ducasse , B. Jurado , L. Mathieu , P. Marini , B. Morillon , M. Aiche , I. Tsekhanovich

We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-projection chamber. Starting with the recent release of the…

XENON is a novel liquid xenon experiment concept for a sensitive dark matter search using a 1-tonne active target, distributed in an array of ten independent time projection chambers. The design relies on the simultaneous detection of…

We present systematic case studies to investigate the sensitivity of axion searches by liquid xenon detectors, using the axio-electric effect (analogue of the photoelectric effect) on xenon atoms. Liquid xenon is widely considered to be one…

Cosmology and Nongalactic Astrophysics · Physics 2015-06-11 K. Arisaka , P. Beltrame , C. Ghag , J. Kaidi , K. Lung , A. Lyashenko , R. D. Peccei , P. Smith , K. Ye

The article deals with the detection efficiency of UV-photon detectors consisting of Thick Gas Electron Multipliers (THGEM) coated with CsI photocathode, operated in atmospheric Ne/CH4 and Ne/CF4 mixtures. We report on the photoelectron…

We perform a theoretical study of the scintillation efficiency in the low-energy region crucial for liquid-xenon dark-matter detectors. We develop a computer program to simulate the cascading process of the recoiling xenon nucleus in liquid…

Instrumentation and Detectors · Physics 2013-10-10 Wei Mu , Xiaonu Xiong , Xiangdong Ji

The implementation of a monolithic fiber-optically coupled CMOS-based TemCam-XF416 camera into our ultra-high vacuum (UHV) ultrafast reflection high-energy electron diffraction setup is reported. A combination of a pumpable gate valve and a…

Mesoscale and Nanoscale Physics · Physics 2024-11-20 Jonas D. Fortmann , Alexander Kaßen , Christian Brand , Thomas Duden , Michael Horn-von Hoegen

First observation of liquid xenon scintillation due to alpha-particles and gamma-rays with a large area avalanche photodiode immersed in the liquid is reported. An energy resolution of 10% (FWHM) and a coincidence time resolution of less…

Instrumentation and Detectors · Physics 2015-06-26 V. N. Solovov , A. Hitachi , V. Chepel , M. I. Lopes , R. Ferreira Marques , A. J. P. L. Policarpo

A novel composite, scintillating material intended for neutron detection and composed of small (1.5 mm) cubes of KG2-type lithium glass embedded in a matrix of scintillating plastic has been developed in the form of a 2.2 in.-diameter, 3.1…

Instrumentation and Detectors · Physics 2015-05-27 G. C. Rich , K. Kazkaz , H. P. Martinez , T. Gushue

The Light only Liquid Xenon (LoLX) experiment is a prototype detector aimed to study liquid xenon (LXe) light properties and various photodetection technologies. LoLX is also aimed to quantify LXe's time resolution as a potential…

Following work done in the energy region above 100 keV, the high-precision calibration of a co-axial high-purity germanium detector has been continued in the energy region below 100 keV. Previous measurements or Monte-Carlo simulations have…

Instrumentation and Detectors · Physics 2020-04-08 B. Blank , P. Ascher , M. Gerbaux , J. Giovinazzo , S. Grevy , T. Kurtukian Nieto , M. Versteegen , J. C. Thomas

We achieve high detectivity terahertz sensing using a silicon nitride nanomechanical resonator functionalized with a metasurface absorber. High performances are achieved by striking a fine balance between the frequency stability of the…