Related papers: Measuring a Charge-Coupled Device Point Spread Fun…
The barrel region of the CMS pixel detector will be equipped with ``n-in-n'' type silicon sensors. They are processed on DOFZ material, use the moderated p-spray technique and feature a bias grid. The latter leads to a small fraction of the…
Due to the increased commercial availability, wide-bandgap semiconductors and their radiation hardness have recently received increased interest from the particle physics community. 4H-Silicon Carbide (SiC), especially, is an attractive…
The knowledge of the point spread function (PSF) of imaging instruments represents a fundamental requirement for astronomical observations. The Herschel PACS PSFs delivered by the instrument control centre are obtained from observations of…
The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise…
We introduce a new software package for modeling the point-spread function (PSF) of astronomical images, called Piff (PSFs In the Full FOV), which we apply to the first three years (known as Y3) of the Dark Energy Survey (DES) data. We…
As part of the astrometric Hubble Space Telescope (HST) large program GO-12911, we conduct an in-depth study to characterize the point spread function (PSF) of the Uv-VISual channel (UVIS) of the Wide Field Camera 3 (WFC3), as a necessary…
A new method is presented for determining the Point Spread Function (PSF) of images that lack bright and isolated stars. It is based on the same principles as the MCS (Magain, Courbin, Sohy, 1998) image deconvolution algorithm. It uses the…
One of the basic parameters of a CCD camera is its gain, i.e. the number of detected electrons per output Analogue to Digital Unit (ADU). This is normally determined by finding the statistical variances from a series of flat-field exposures…
We have developed a non-destructive readout system that uses a floating-gate amplifier on a thick, fully depleted charge coupled device (CCD) to achieve ultra-low readout noise of 0.068 e- rms/pix. This is the first time that discrete…
In order to achieve a large deployment of renewable energies, the electricity production costs have to be as low as possible. Many different technologies have been proposed to achieve the best efficiency to cost ratio. One of those is…
To understand the scientific imaging capability, one must characterize the intra-pixel sensitivity variation (IPSV) of the CMOS image sensor. Extracting an IPSV map contributes to an improved detector calibration that allows to eliminate…
Interferometric scattering (iSCAT) microscopy is an emerging label-free technique optimized for the sensitive detection of nano-matter. Previous iSCAT studies have approximated the point spread function in iSCAT by a Gaussian intensity…
This study presents a comprehensive end-to-end simulation analysis of the optical imaging performance of the China Survey Space Telescope (CSST) under in-orbit conditions. An integrated system model incorporating five static and two dynamic…
The ST-ECF Calibration Enhancement effort for the Space Telescope Imaging Spectrograph (STIS) aims to improve data calibration via the application of physical modelling techniques. As part of this effort we have developed a model of the…
A charge-coupled device (CCD) is a standard imager in optical region in which the image quality is limited by its pixel size. CCDs also function in X-ray region but with substantial differences in performance. An optical photon generates…
Small collection-electrode monolithic CMOS sensors profit from a high signal-to-noise ratio and a small power consumption, but have a limited active sensor volume due to the fabrication process based on thin high-resistivity epitaxial…
The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…
An accurate model of the point spread function is required in order to estimate positions and brightnesses of stars in digitized images. The PSF of the Gaia space telescope is unusual due to the use of drift-scan mode and time-delayed…
In this paper we present a detailed impact study of semi-inclusive deep inelastic scattering unpolarized cross sections' measurements using the proposed SoLID apparatus at Jefferson Lab. This type of data, collected at large Bjorken…
Based on grating diffraction principle, optical fiber transmission principle and optical interference principle, a multi-functional portable optical measuring instrument is constructed in this paper. The optical measurement visualization…