Related papers: Measuring a Charge-Coupled Device Point Spread Fun…
We provide a systematic study of the position-dependent correlation function in weak lensing convergence maps and its relation to the squeezed limit of the three-point correlation function (3PCF) using state-of-the-art numerical…
Point spread function (PSF) plays an essential role in image reconstruction. In the context of confocal microscopy, optical performance degrades towards the edge of the field of view as astigmatism, coma and vignetting. Thus, one should…
Interaction of charges in CCDs with the already accumulated charge distribution causes both a flux dependence of the point-spread function (an increase of observed size with flux, also known as the brighter/fatter effect) and pixel-to-pixel…
The point spread function (PSF) is fundamental to any type of microscopy, most importantly so for single-molecule localization techniques, where the exact PSF shape is crucial for precise molecule localization at the nanoscale. However,…
Future X-ray astrophysics missions will survey large areas of the sky with unparalleled sensitivity, enabled by lightweight, high-resolution optics. These optics inherently produce curved focal surfaces with radii as small as 2 m, requiring…
Recently introduced angular-memory-effect based techniques enable non-invasive imaging of objects hidden behind thin scattering layers. However, both the speckle-correlation and the bispectrum analysis are based on the statistical average…
Recently, low light level charge coupled devices (L3CCDs) capable of on-chip gain have been developed, leading to sub-electron effective readout noise, allowing for the detection of single photon events. Optical interferometry usually…
LensMC is a weak lensing shear measurement method developed for Euclid and Stage-IV surveys. It is based on forward modelling in order to deal with convolution by a point spread function (PSF) with comparable size to many galaxies; sampling…
In this work we derive analytic expressions and numerical recipes for finding the effective observed position of sources close enough on sky that their Point Spread Functions (PSF), modelled as Gaussian profiles, overlap. In particularly we…
We have developed a wide-gap CdTe double-sided strip detector (CdTe-DSD) for the fourth and fifth flights of the Focusing Optics X-ray Solar Imager sounding rocket experiment (FOXSI-4/FOXSI-5). This detector features a 30 um strip width and…
Accessing the point-spread function (PSF) of a complex optical system is important for a variety of imaging applications. However, placing an invasive point source is often impractical, and estimating it blindly with multiple frames is slow…
Here we describe the implementation and calibration of a streaked visible spectrometer (SVS) for optical pyrometry and emission/absorption spectroscopy on light gas gun platforms in the UC Davis Shock Compression Laboratory. The diagnostic…
Thorough numerical simulations were run to test the performance of three processing methods of the data coming out from an electron multiplying charge coupled device (EMCCD), or low light level charge coupled device (L3CCD), operated at…
Leveraging multi-modal fusion, especially between camera and LiDAR, has become essential for building accurate and robust 3D object detection systems for autonomous vehicles. Until recently, point decorating approaches, in which point…
X-ray cone-beam computed tomography (CT) has the notable features such as high efficiency and precision, and is widely used in the fields of medical imaging and industrial non-destructive testing, but the inherent imaging degradation…
We present the point-spread function (PSF) of the Extreme Ultraviolet High-Resolution Imager (HRIEUV) onboard Solar Orbiter, which observes the Sun at 174 Angstrom. This PSF provides a quantitative description of light diffracted by the…
In this work, we present a planar laser-induced fluorescence (PLIF) system for two-dimensional (2D) spatial and phase-resolved ion velocity distribution function (IVDF) measurements. A continuous-wave tunable diode laser produces a laser…
We present the two kinds of experimental results. One is a continuous variable dense coding experiment, and the other is a photon number detector with high linearity response, the so called charge integration photon detector (CIPD). They…
High quality, repeatable point-spread functions are important for science cases like direct exoplanet imaging, high-precision astrometry, and high-resolution spectroscopy of exoplanets. For such demanding applications, the initial on-sky…
We present results of inflight calibration of the point spread function (PSF) of the Soft X-ray Telescope (SXT-S) that focuses X-ray onto the pixel array of the Soft X-ray Spectrometer system (SXS). We make a full array image of a…