Scatter can account for large errors in cone-beam CT (CBCT) due to its wide field of view, and its complicated nature makes its compensation difficult. Iterative polyenergetic reconstruction algorithms offer the potential to provide…

Medical Physics · Physics 2020-01-13 Jonathan H. Mason , Alessandro Perelli , William H. Nailon , Mike E. Davies

In x-ray coherent scatter tomography, tomographic measurements of the forward scatter distribution are used to infer scatter densities within a volume. A radiopaque 2D pattern placed between the object and the detector array enables the…

Algorithmic X-ray scatter compensation is a desirable technique in flat-panel X-ray imaging and cone-beam computed tomography. State-of-the-art U-net based image translation approaches yielded promising results. As there are no physics…

Scatter signals can degrade the contrast and resolution of computed tomography (CT) images and induce artifacts. How to effectively correct scatter signals in CT has always been a focal point of research for researchers. This work presents…

Medical Physics · Physics 2025-01-10 Guiyuan Lin , Shiwo Deng , Xiaoqun Wang , Xing Zhao

Background: Recently, the popularity of dual-layer flat-panel detector (DL-FPD) based dual-energy cone-beam CT (DE-CBCT) imaging has been increasing. However, the image quality of DE-CBCT remains constrained by the Compton scattered X-ray…

Multi-MeV flash radiography is often used as the primary diagnostic technique for high energy and density (HED) physics experiments. Primary X-ray which is attenuated by the object offers density information of the object. For a thick metal…

Applied Physics · Physics 2021-12-02 Qinggang Jia , Peng-Cheng Mao , Yang-Bo , Dun-Fu Shi , Ling-Yu Zhang , Deng-Li , Hai-Bo Xu

Purpose: Cone-beam CT (CBCT) projection images provide anatomical data in real-time over several respiratory cycles, forming a comprehensive picture of tumor movement. We developed and validated a method which uses these projections to…

Medical Physics · Physics 2015-01-15 Bernard L. Jones , David Westerly , Moyed Miften

Scattered coincidences introduce quantitative bias in positron emission tomography (PET) and must be compensated during reconstruction. Conventional scatter estimates typically rely on simplified cylindrical scanner models that omit…

Measuring scattered light is central to many laser-based gas diagnostic techniques, e.g., coherent anti-Stokes Raman spectroscopy (CARS) and filtered Rayleigh scattering (FRS). To produce quantitative measurements with such techniques, a…

Computational Physics · Physics 2020-05-18 Gregory J. Hunt , Cody R. Ground , Robin L. Hunt

In this paper, we review the main problem concerning the calculation of X-ray scattering of simulated model systems, namely their finite size. A novel method based on the Rayleigh-Debye-Gans approximation was derived, which allows…

Statistical Mechanics · Physics 2010-11-10 Andrej Lajovic , Matija Tomšič , Andrej Jamnik

Doing quantitative computed tomography (CT) using Bremsstrahlung sources requires an estimate of the spectrum emitted by the X-ray source. One method of beam hardening correction (BHC), as described by Lifton[1], first uses transmission…

Medical Physics · Physics 2025-08-13 Nikhil Deshmukh

Diagnostic stroke imaging with C-arm cone-beam computed tomography (CBCT) enables reduction of time-to-therapy for endovascular procedures. However, the prolonged acquisition time compared to helical CT increases the likelihood of rigid…

Image and Video Processing · Electrical Eng. & Systems 2019-12-02 Alexander Preuhs , Michael Manhart , Philipp Roser , Bernhard Stimpel , Christopher Syben , Marios Psychogios , Markus Kowarschik , Andreas Maier

Conventional cone-beam CT (CBCT) can be easily compromised by scatter and beam hardening artifacts, and the entanglement of scatter and spectral effects introduces additional complexity. In this work, we present the first attempt to develop…

Medical Physics · Physics 2025-01-07 Yifan Deng , Hao Zhou , Zhilei Wang , Adam S. Wang , Hewei Gao

Aberration correction is an important aspect of modern high-resolution scanning transmission electron microscopy. Most methods of aligning aberration correctors require specialized sample regions and are unsuitable for fine-tuning…

The purpose of this study is to correct the movement errors that may occur because of the patients' movement during the CT scanning and thus, to obtain more precise CT images, additionally to investigate the possible use of Parallel Beam CT…

Medical Physics · Physics 2020-05-08 Seokhwan Yoon , Seong-Kyun Kim , Kyungtaek Jun

With the emergence of CNT (Carbon nanotube), static and instant CT scanning becomes possible. By transforming the traditionally rotated thermal source into a static ring array source composed of multiple CNTs, the imaging system can achieve…

Medical Physics · Physics 2025-02-11 Jiayu Duan , Yang Li , Jianmei Cai , Xuanqin Mou

While model-based reconstruction methods have been successfully applied to flat-panel cone-beam CT (FP-CBCT) systems, typical implementations ignore both spatial correlations in the projection data as well as system blurs due to the…

Medical Physics · Physics 2017-06-20 Steven Tilley , Jeffrey H. Siewerdsen , J. Webster Stayman

Cone-beam computed tomography (CBCT) offers advantages over conventional fan-beam CT in that it requires a shorter time and less exposure to obtain images. CBCT has found a wide variety of applications in patient positioning for…

Computer Vision and Pattern Recognition · Computer Science 2020-07-01 S. Kida , S. Kaji , K. Nawa , T. Imae , T. Nakamoto , S. Ozaki , T. Ohta , Y. Nozawa , K. Nakagawa

Computer-Assisted Interventions enable clinicians to perform precise, minimally invasive procedures, often relying on advanced imaging methods. Cone-beam computed tomography (CBCT) can be used to facilitate computer-assisted interventions,…

Image and Video Processing · Electrical Eng. & Systems 2024-12-04 Maximilian E. Tschuchnig , Philipp Steininger , Michael Gadermayr

In industrial X-ray Computed Tomography (CT), the need for rapid in-line inspection is critical. Sparse-angle tomography plays a significant role in this by reducing the required number of projections, thereby accelerating processing and…

Computer Vision and Pattern Recognition · Computer Science 2025-05-27 Tianyuan Wang , Felix Lucka , Daniël M. Pelt , K. Joost Batenburg , Tristan van Leeuwen