High light collection efficiency is an important requirement in any application of scintillation detectors. The purpose of this study is to investigate the possibility for improving this parameter in cryogenic scintillation bolometers,…

Instrumentation and Detectors · Physics 2014-02-11 F. A. Danevich , R. V. Kobychev , V. V. Kobychev , H. Kraus , V. B. Mikhailik , V. M. Mokina

Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we present the TREX-DM experiment, a low background…

A direct WIMP (Weakly Interacting Massive Particle) detector with a neutron veto system is designed to better reject neutrons. An experimental configuration is studied in the present paper: 984 Ge modules are placed inside a reactor…

Instrumentation and Methods for Astrophysics · Physics 2019-10-11 Ye Xu , Jieqin Lan , Yin Bai , Weiwei Gao

The CDMS II experiment uses Z-dependent Ionization Phonon (ZIP) detectors made of Germanium and Silicon to identify nuclear recoils from Weakly Interacting Massive Particles (WIMPs) with near complete event-by-event rejection of various…

Astrophysics · Physics 2007-05-23 Samuel Leclercq

This work reports on the development of the first phonon detectors based on CaMoO4 and ZnWO4 scintillating crystals for the CRESST-II experiment. In particular, a novel technique for the production of the ZnWO4 phonon detector with a…

Astrophysics · Physics 2008-11-13 I. Bavykina , G. Angloher , D. Hauff , M. Kiefer , F. Petricca , F. Proebst

The sensitivity of neutrinoless double beta (0n2b) decay experiments is mainly depended on the internal background of a detector which, in its turn, is defined by the purity of material and possibility for selection of background events.…

Instrumentation and Detectors · Physics 2013-04-17 Nikita Khanbekov , Vladimir Alenkov , Aleksander Burenkov , Oleg Buzanov , HongJoo Kim , Vasily Kornoukhov , JungHo So

We report first results from the Cryogenic Dark Matter Search (CDMS II) experiment running with its full complement of 30 cryogenic particle detectors at the Soudan Underground Laboratory. This report is based on the analysis of data…

Astrophysics · Physics 2012-08-27 CDMS Collaboration

Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we describe the TREX-DM experiment, a low background…

Instrumentation and Detectors · Physics 2016-06-22 F. J. Iguaz , J. G. Garza , F. Aznar , J. F. Castel , S. Cebrian , T. Dafni , J. A. Garcia , I. G. Irastorza , A. Lagraba , G. Luzon , A. Peiro

We are conducting an experiment to search for WIMPs, or weakly-interacting massive particles, in the galactic halo using terrestrial detectors. This generic class of hypothetical particles, whose properties are similar to those predicted by…

Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we describe the TREX-DM experiment, a low background…

Instrumentation and Detectors · Physics 2015-09-08 F. J. Iguaz , J. G. Garza , F. Aznar , J. F. Castel , S. Cebrian , T. Dafni , J. A. Garcia , I. G. Irastorza , A. Lagraba , G. Luzon , A. Peiro

The Cryogenic Dark Matter Search (CDMS) and XENON experiments aim to directly detect dark matter in the form of weakly interacting massive particles (WIMPs) via their elastic scattering on the target nuclei. The experiments use different…

Astrophysics · Physics 2008-11-26 Kaixuan Ni , Laura Baudis

I describe the new instrumentation for the SIMPLE dark matter search experiment, and its use in identifying, validating and rejecting non-WIMP backgrounds in the first stage of the Phase II project measurements. Beyond intrinsic acoustic…

Instrumentation and Methods for Astrophysics · Physics 2011-01-11 M. Felizardo

We have developed and tested a new way of coupling bolometric light detectors to scintillating crystal bolometers based upon simply resting the light detector on the crystal surface, held in position only by gravity. This straightforward…

Instrumentation and Detectors · Physics 2019-05-30 M. Barucci , J. W. Beeman , V. Caracciolo , L. Pagnanini , L. Pattavina , G. Pessina , S. Pirro , C. Rusconi , K. Schäffner

The ZEPLIN-III experiment is operating in its second phase at the Boulby Underground Laboratory in search of dark matter WIMPs. The major upgrades to the instrument over its first science run include lower background photomultiplier tubes…

The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)$\times10^{-12}$\,pb at a WIMP mass of 40 GeV/$c^2$. This paper describes the simulations framework that, along…

Instrumentation and Detectors · Physics 2020-06-25 ZEPLIN Collaboration , D. S. Akerib , C. W. Akerlof , A. Alqahtani , S. K. Alsum , T. J. Anderson , N. Angelides , H. M. Araújo , J. E. Armstrong , M. Arthurs , X. Bai , J. Balajthy , S. Balashov , J. Bang , D. Bauer , A. Baxter , J. Bensinger , E. P. Bernard , A. Bernstein , A. Bhatti , A. Biekert , T. P. Biesiadzinski , H. J. Birch , K. E. Boast , B. Boxer , P. Brás , J. H. Buckley , V. V. Bugaev , S. Burdin , J. K. Busenitz , R. Cabrita , C. Carels , D. L. Carlsmith , M. C. Carmona-Benitez , M. Cascella , C. Chan , N. I. Chott , A. Cole , A. Cottle , J. E. Cutter , C. E. Dahl , L. de Viveiros , J. E. Y. Dobson , E. Druszkiewicz , T. K. Edberg , S. R. Eriksen , A. Fan , S. Fayer , S. Fiorucci , H. Flaecher , E. D. Fraser , T. Fruth , R. J. Gaitskell , J. Genovesi , C. Ghag , E. Gibson , M. G. D. Gilchriese , S. Gokhale , M. G. D. van der Grinten , C. R. Hall , A. Harrison , S. J. Haselschwardt , S. A. Hertel , J. Y-K. Hor , M. Horn , D. Q. Huang , C. M. Ignarra , O. Jahangir , W. Ji , J. Johnson , A. C. Kaboth , A. C. Kamaha , K. Kamdin , K. Kazkaz , D. Khaitan , A. Khazov , I. Khurana , C. D. Kocher , L. Korley , E. V. Korolkova , J. Kras , H. Kraus , S. Kravitz , L. Kreczko , B. Krikler , V. A. Kudryavtsev , E. A. Leason , J. Lee , D. S. Leonard , K. T. Lesko , C. Levy , J. Li , J. Liao , F. -T. Liao , J. Lin , A. Lindote , R. Linehan , W. H. Lippincott , R. Liu , X. Liu , C. Loniewski , M. I. Lopes , B. López Paredes , W. Lorenzon , S. Luitz , J. M. Lyle , P. A. Majewski , A. Manalaysay , L. Manenti , R. L. Mannino , N. Marangou , M. F. Marzioni , D. N. McKinsey , J. McLaughlin , Y. Meng , E. H. Miller , E. Mizrachi , A. Monte , M. E. Monzani , J. A. Morad , E. Morrison , B. J. Mount , A. St. J. Murphy , D. Naim , A. Naylor , C. Nedlik , C. Nehrkorn , H. N. Nelson , F. Neves , J. A. Nikoleyczik , A. Nilima , I. Olcina , K. C. Oliver-Mallory , S. Pal , K. J. Palladino , J. Palmer , N. Parveen , E. K. Pease , B. Penning , G. Pereira , A. Piepke , K. Pushkin , J. Reichenbacher , C. A. Rhyne , A. Richards , Q. Riffard , G. R. C. Rischbieter , R. Rosero , P. Rossiter , G. Rutherford , D. Santone , A. B. M. R. Sazzad , R. W. Schnee , M. Schubnell , P. R. Scovell , D. Seymour , S. Shaw , T. A. Shutt , J. J. Silk , C. Silva , R. Smith , M. Solmaz , V. N. Solovov , P. Sorensen , I. Stancu , A. Stevens , K. Stifter , T. J. Sumner , N. Swanson , M. Szydagis , M. Tan , W. C. Taylor , R. Taylor , D. J. Temples , P. A. Terman , D. R. Tiedt , M. Timalsina , A. Tomás , M. Tripathi , D. R. Tronstad , W. Turner , L. Tvrznikova , U. Utku , A. Vacheret , A. Vaitkus , J. J. Wang , W. Wang , J. R. Watson , R. C. Webb , R. G. White , T. J. Whitis , F. L. H. Wolfs , D. Woodward , X. Xiang , J. Xu , M. Yeh , P. Zarzhitsky

The p-type point-contact germanium detectors are novel techniques offering kg-scale radiation sensors with sub-keV sensitivities. They have been used for light Dark Matter WIMPs searches and may have potential applications in neutrino…

Instrumentation and Detectors · Physics 2014-03-14 H. B. Li , the TEXONO Collaboration

Bolometric detectors are excellent devices for the investigation of neutrinoless double-beta decay (0$\nu\beta\beta$). The observation of such decay would demonstrate the violation of lepton number, and at the same time it would necessarily…

The analysis presented in the recent publication of the CRESST-II results finds a statistically significant excess of registered events over known background contributions in the acceptance region and attributes the excess to a possible…

Instrumentation and Methods for Astrophysics · Physics 2012-08-20 M. Kuźniak , M. G. Boulay , T. Pollmann

The WIMP proposed here yields the observed abundance of dark matter, and is consistent with the current limits from direct detection, indirect detection, and collider experiments, if its mass is $\sim 72$ GeV/$c^2$. It is also consistent…

High Energy Physics - Phenomenology · Physics 2021-08-02 Reagan Thornberry , Maxwell Throm , Gabriel Frohaug , John Killough , Dylan Blend , Michael Erickson , Brian Sun , Brett Bays , Roland E. Allen

Three dark matter direct detection experiments (DAMA/LIBRA, CoGeNT, and CRESST-II) have each reported signals which are not consistent with known backgrounds, but resemble that predicted for a dark matter particle with a mass of roughly…

Cosmology and Nongalactic Astrophysics · Physics 2013-05-30 Chris Kelso , Dan Hooper , Matthew R. Buckley