English
Related papers

Related papers: Injection performance evaluation for storage ring …

200 papers

Revolution frequency measurements of individual ions in storage rings require sophisticated timing detectors. One of common approaches for such detectors is the detection of secondary electrons released from a thin foil due to penetration…

We improved a previously proposed method of using closed-orbit modulation for linear optics correction. Instead of fitting individual closed orbits, the improved method decomposes the orbit oscillation data into two orthogonal modes and…

Accelerator Physics · Physics 2023-06-14 Xiaobiao Huang , Xi Yang

Here, results are presented on the focusing of $1 \ \mu$m polystyrene particle suspensions using a synchronous oscillatory pressure-driven flow and oscillatory electric field in a microfluidic device. The effect of the phase difference…

Fluid Dynamics · Physics 2023-12-13 Giridar Vishwanathan , Gabriel Juarez

M\"ossbauer spectroscopy is a technique employed to investigate the microscopic properties of materials using transitions between energy levels in the nuclei. Conventionally, in synchrotron-radiation-based M\"ossbauer spectroscopy, the…

Computational Physics · Physics 2026-02-23 Binsheu Shieh , Ryo Masuda , Satoshi Tsutsui , Shun Katakami , Kenji Nagata , Masaichiro Mizumaki , Masato Okada

In order to double the positron injection rate into the KEKB ring, a two-bunch acceleration scheme has been studied at the linac, in which bunches separated by 96 ns are accelerated in 50 Hz. In this scheme the stabilization of energy and…

Accelerator Physics · Physics 2010-11-15 K. Furukawa , N. Kamikubota , T. Suwada , T. Obata

A charge injection technique is applied to the X-ray CCD camera, XIS (X-ray Imaging Spectrometer) onboard Suzaku. The charge transfer inefficiency (CTI) in each CCD column (vertical transfer channel) is measured by the injection of charge…

A combination of the H- stripping and phase space painting method is used to accumulate a high intensity beam in the Rapid Cycling Synchrotron (RCS) of the China Spallation Neutron Source (CSNS). The injection system for CSNS/RCS consists…

For heavy-ion synchrotrons an efficient Multi-Turn Injection (MTI) from the injector linac is crucial in order to reach the specified currents using the available machine acceptance. The beam loss during the MTI must not exceed the limits…

Accelerator Physics · Physics 2014-03-25 Sabrina Appel , Oliver Boine-Frankenheim

Localization and tracking are critical components of integrated sensing and communication (ISAC) systems, enhancing resource management, beamforming accuracy, and overall system reliability through precise sensing. Due to the high path loss…

Signal Processing · Electrical Eng. & Systems 2025-02-20 Xueting Xu , Hui Chen , Shengqiang Shen , Hyowon Kim , Xu Fang , Ao Peng , Fan Jiang , Henk Wymeersch

Magnet errors in storage rings significantly degrade beam performance, impacting the brightness and stability of the light source. Therefore, beam-based correction is crucial for the safe operation of machines and the stability of radiated…

Accelerator Physics · Physics 2025-12-18 Jianhao Xu

The Isochronous Mass Spectrometry (IMS) is a powerful technique developed in heavy-ion storage rings for measuring masses of very short-lived exotic nuclei. The IMS is based on the isochronous setting of the ring. One of the main parameters…

In this chapter we give an introduction to the transverse dynamics of the particles in a synchrotron or storage ring. The emphasis is more on qualitative understanding rather than on mathematical correctness, and a number of simulations are…

Accelerator Physics · Physics 2014-04-04 B. J. Holzer

We report on the injection locking of an optically levitated nanomechanical oscillator (a silica nanosphere) to resonant intensity modulations of an external optical signal. We explore the characteristic features of injection locking in…

Silicon detectors play a crucial role in high energy physics experiments. In future high energy physics experiments, silicon detectors will be exposed to extremely high fluence environment, which can significantly affect their performance.…

Instrumentation and Detectors · Physics 2025-12-11 Xingchen Li , Chenxi Fu , Hui Li , Zhan Li , Lin Zhu , Congcong Wang , Xiyuan Zhang , Weimin Song , Hui Liang , Cong Liu , Hongbo Wang , Xin Shi , Suyu Xiao

In KEKB, synchrotron radiation interferometers (SRMs) are used for measuring the transverse beam sizes. There is also a tool for enlarging the vertical beam size intentionally by making an asymmetric bump, called an ``iSize'' bump, at one…

Accelerator Physics · Physics 2007-07-05 N. Iida , J. Flanagan , Y. Funakoshi , K. Oide

Several heuristic procedures to estimate the rotor position of permanent magnet synchronous motors (PMSM) via signal injection have been reported in the literature. Using averaging theory, a framework to analyse such schemes has been…

Systems and Control · Computer Science 2020-03-17 Bowen Yi , Slobodan N. Vukosavic , Romeo Ortega , Aleksandar M. Stankovic , Weidong Zhang

In this paper we introduce SAIBERSOC, a tool and methodology enabling security researchers and operators to evaluate the performance of deployed and operational Security Operation Centers (SOCs) (or any other security monitoring…

Cryptography and Security · Computer Science 2020-10-19 Martin Rosso , Michele Campobasso , Ganduulga Gankhuyag , Luca Allodi

High precision Low-level RF (LLRF) control and monitoring systems for future particle accelerators will be a significant technical challenge as the requirements in performance, flexibility and affordability become increasingly stringent. We…