Related papers: A simple technique for gamma ray and cosmic ray sp…
Chromatic calorimetry (CCAL) analyses particle detection by utilizing scintillators with distinct emission wavelengths to measure the longitudinal energy deposition of particle showers in high-energy physics, improving particle…
Modern detectors of cosmic gamma-rays are a special type of imaging telescopes (air Cherenkov telescopes) supplied with cameras with a relatively large number of photomultiplier-based pixels. For example, the camera of the TAIGA-IACT…
In this work we explore for the first time the applicability of using $\gamma$-ray imaging in neutron capture measurements to identify and suppress spatially localized background. For this aim, a pinhole gamma camera is assembled, tested…
All of the present methods for calibration and monitoring of TOF-PET scanner detectors utilize radioactive isotopes such as e.g. $^{22}$Na or $^{68}$Ge, which are placed or rotate inside the scanner. In this article we describe a novel…
Scattering measurements with incident linearly polarized $\gamma$ rays provide information on spins, parities, and $\gamma$-ray multipolarity mixing coefficients, and, therefore, on the nuclear matrix elements involved in the transitions.…
Plastic scintillators are widely used for the detection of elementary particles, and 3D reconstruction of particle tracks is achieved by segmenting the detector into 3D granular structures. In this study, we present a novel prototype…
The spectrum of laser-plasma-generated X-rays is very important as it can characterize electron dynamics and also be useful for applications, and nowadays with the forthcoming high-repetition-rate laser-plasma experiments, there is a…
We constructed a gamma-ray detector by combining two types of scintillator array detectors with an MPPC array and evaluated the spectral performance by reading out the signals from the MPPC with a low-power integrated circuit (ASIC)…
We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up…
In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and $\gamma$-ray Compton scatterer of the novel dual \g-ray and neutron imaging system GN-Vision, which aims at…
Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…
Novel Positron Emission Tomography system, based on plastic scintillators, is developed by the J-PET collaboration. In order to optimize geometrical configuration of built device, advanced computer simulations are performed. Detailed study…
It is a recurrent issue in astronomical data analysis that observations are unevenly sampled or incomplete maps with missing patches or intentionaly masked parts. In addition, many astrophysical emissions are non stationary processes over…
The cosmic rays data collected using a large area plastic scintillator array ISMRAN (Indian Scintillator Matrix for Reactor AntiNeutrino) are presented. The data collected serve as a useful benchmark of cosmogenic background in a…
Compton telescope is a promising technology to achieve very high sensitivity in the soft gamma-ray band (0.1-10 MeV) by utilizing Compton kinematics. Compton kinematics also enables polarization measurement which will open new windows to…
The detection of photons above 10 keV through MeV and GeV energies is challenging due to the penetrating nature of the radiation, which can require large detector volumes, resulting in correspondingly high background. In this energy range,…
A systematic study is conducted to understand the coincident resolving time (CRT) for a pair of Lutetium-yttrium oxyorthosilicate (LYSO) and the plastic scintillation detector bars under the Geant4 framework. Crystals are coupled to a…
Plastic scintillator detectors with three-dimensional granularity and sub-nanosecond time resolution offer simultaneous particle tracking, identification, and calorimetry. However, scaling to larger volumes and finer segmentation poses…
The detectors based on the liquid scintillator (LS) monitored by an array of photo-multiplier tubes (PMT) are often used in low energy experiments such as neutrino oscillation studies and search for dark matter. Detectors of this kind…
A plastic scintillator bar with dimensions 300 cm x 2.5 cm x 11 cm was exposed to a focused muon beam to study its light yield and timing characteristics as a function of position and angle of incidence. The scintillating light was read out…