Related papers: Traceable precision pA direct current measurements…
A high-precision charge measurement can be achieved by the area integration of a digitized quasi-Gaussian signal after the signal passes through the shaper and analog-to-digital converter (ADC). The charge measurement contains an error due…
We propose a kernel-PCA based method to detect anomaly in chemical sensors. We use temporal signals produced by chemical sensors to form vectors to perform the Principal Component Analysis (PCA). We estimate the kernel-covariance matrix of…
High-power amplifiers are of great importance in many optical systems deployed in optical sensing, ranging, medical surgery, material processing and more. Likewise, high-gain, low-noise amplifiers with low polarization dependence are…
The precision of synchronization algorithms based on the theory of pulse-coupled oscillators is evaluated on FPGA-based radios for the first time. Measurements show that such algorithms can reach precision in the low microsecond range when…
Detector calibration is very important for the long-term operation. For the purposes of simple and precise calibration, we developed a new portable calibration source using UVLED to calibrate the fluorescence detector of the Telescope Array…
We experimentally show that the Inelastic Cooper-Pair Tunneling Amplifier (ICTA), implementing a DC-powered parametric amplification scheme, can achieve gain and noise performance similar to that of Josephson parametric amplifiers. Using…
Fiber-reinforced pneumatic twisted-and-coiled actuators (FR-PTCAs) offer high power density and compliance but their strong hysteresis and lack of intrinsic proprioception limit effective closed-loop control. This paper presents a…
Linear Collider Alignment and Survey (LiCAS) R&D group is proposing a novel automated metrology instrument dedicated to align and monitor the mechanical stability of a future linear high energy e+e- collider. LiCAS uses Laser Straightness…
This paper describes the setup and the results of the direct on-wafer measurements of a FET noise parameters obtained with a source-pull method at temperatures down to T=4K and in the 5-12 GHz frequency range. The setup consists of a…
Extremely large-scale multi-input multi-output (XL-MIMO) is a promising technology for the sixth generation (6G) wireless networks, thanks to its superior spatial resolution and beamforming gains. In order to realize XL-MIMO…
In future B5G/6G broadband communication systems, non-linear signal distortion caused by the impairment of transmit power amplifier (PA) can severely degrade the communication performance, especially when uplink users share the wireless…
This research examines the stability of crossed-field amplifiers (CFAs) and characterizes their different modes of operation: amplification, driven oscillation, and self-excited oscillation. The CFA used in this paper is the Recirculating…
We describe a microwave amplifier based on the Superconducting Low-inductance Undulatory Galvanometer (SLUG). The SLUG is embedded in a microstrip resonator, and the signal current is injected directly into the device loop. Measurements at…
We prototype a PCB-realized tunable load network whose ports serve as additional "virtual" VNA ports in a "Virtual VNA" measurement setup. The latter enables the estimation of a many-port antenna array's scattering matrix with a few-port…
We compare the vacuum measured by two portable cold-atom vacuum standards (pCAVS) based on ultracold $^7$Li atoms. The pCAVS are quantum-based standards that use a priori scattering calculations to convert a measured loss rate of cold atoms…
We describe application of a state-of-the art digital FPGA based Lock-In amplifier to measurements of ultrasound propagation and attenuation at fixed frequency in low temperatures and in high static magnetic fields. Our implementation…
This paper presents analysis for target detection using tightly-coupled antenna (TCA) arrays with high mutual coupling (MC). We show that the wide operational bandwidth of TCAs is advantageous for target detection. We assume a sensing…
We demonstrate a microfabricated optomechanical accelerometer that is capable of percent-level accuracy without external calibration. To achieve this capability, we use a mechanical model of the device behavior that can be characterized by…
The true-differential superconductor on-chip amplifier has complementary outputs that float with respect to chip ground. This improves signal integrity and compatibility with the receiving semiconductor stage. Both source-terminated and…
Capacitance measurements are crucial for probing the electrical properties of materials. In this study, we develop and implement a capacitance measurement technique optimized for pulsed magnetic fields. Our approach employs an…