Related papers: Gain Stabilization of SiPMs
The Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of the stability in the working point conditions due to gas…
A setup is designed for measuring the Seebeck coefficient (S) of materials in form of thin film, bar and wire. The main feature of this setup is control in heating and cooling cycles. In this setup heat pulse is used to generate the…
The SiPM-on-Tile technology for highly granular calorimeters, where small plastic scintillator tiles are directly read out with SiPMs, has been developed for the CALICE Analog Hadron Calorimeter, and has been adopted for parts of the…
Three-mode parametric instability is a threat to attaining design power levels in Advanced gravitational wave detectors. The first observation of three-mode parametric instability in a long optical cavity revealed that instabilities could…
Faults and operational disturbances in Heat Recovery Steam Generators (HRSGs), such as valve leakage, present significant challenges, disrupting steam temperature regulation and potentially causing efficiency losses, safety risks, and unit…
This paper presents the design of multivariable temperature control for a refrigeration system based on vapor compression employing the internal model control technique. The refrigeration system is based on the PID18 benchmark, which is a…
Inductance plays a crucial role in the design and optimization of superconducting quantum interference devices (SQUIDs) for quantum sensing applications, since it dictates the sensitivity and coupling ratio with other circuit elements. In…
This paper presents a novel method for enhancing the adaptability of Proportional-Integral-Derivative (PID) controllers in industrial systems using event-based dynamic game theory, which enables the PID controllers to self-learn, optimize,…
In this paper the methodology and the results of a quasi real-time thermal characterization tool and method for the temperature mapping of circuits and boards based on sensing the infrared radiation will be introduced. With the proposed…
Low Gain Avalanche Detectors(LGADs) is one of the candidate sensing technologies for future 4D-tracking applications and recently have been qualified to be used in the ATLAS and CMS timing detectors for the CERN High Luminosity Large Hadron…
This work presents a self-heating study of a 40-nm bulk-CMOS technology in the ambient temperature range from 300 K down to 4.2 K. A custom test chip was designed and fabricated for measuring both the temperature rise in the MOSFET channel…
Injection-type ballistic rectifiers on Si/SiGe are studied with respect to the influence of gate voltage on the transfer resistance RT (output voltage divided by input current) for different positions of a local gate electrode. The…
The increasing share of converter based resources in power systems calls for scalable methods to analyse stability without relying on exhaustive system wide simulations. Decentralized small gain and small-phase criteria have recently been…
At National Institute of Metrological Research (INRIM), an automated setup to calibrate DC Voltage generators, mainly top-level calibrators from 1 mV to 1 kV has been developed. The heart of the setup is an INRIM-built automated fixed…
The response of electric devices to an applied thermal gradient has, so far, been studied almost exclusively in two-terminal devices. Here we present measurements of the response to a thermal bias of a four-terminal, quasi-ballistic…
It is known that the stability of a feedback interconnection of two linear time-invariant systems implies that the graphs of the open-loop systems are quadratically separated. This separation is defined by an object known as the multiplier.…
Networked Control Systems (NCSs) are often associated with problems like random data losses which might lead to system instability. This paper proposes a method based on the use of variable controller gains to achieve maximum parametric…
The operation of the primary Coulomb blockade thermometer (CBT) is based on a measurement of bias voltage dependent conductance of arrays of tunnel junctions between normal metal electrodes. Here we report on a comparison of a CBT with a…
Here, we study the stability of capacitance diaphragm gauges. We focus on their stability before and after a controlled series of bakes. We find that baking results in appreciable shifts of the zero offset, but note that these can easily be…
In this paper we consider the problem of voltage regulation of a proton exchange membrane fuel cell connected to an uncertain load through a boost converter. We show that, in spite of the inherent nonlinearities in the current-voltage…