Related papers: A study of silicon sensor for ILD ECAL
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the…
LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the…
Studies of the response of the SiD silicon-tungsten electromagnetic calorimeter (ECal) are presented. Layers of highly granular (13 mm^2 pixels) silicon detectors embedded in thin gaps (~ 1 mm) between tungsten alloy plates give the SiD…
The ILD detector is proposed for an electron-positron collider with collision centre-of-mass energies from 90~\GeV~to about 1~\TeV. It has been developed over the last 10 years by an international team of scientists with the goal to design…
We are developing position sensitive silicon detectors (PSDs) which have an electrode at each of four corners so that incident position of a charged particle can be obtained with signal from the electrodes. It is expected that the position…
The SiD concept is one of two proposed detectors to be mounted at the interaction region of the International Linear Collider (ILC). A substantial ILC background arises from low transverse momentum $\mathrm{e}^{+}\mathrm{e}^{-}$ pairs…
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high…
The technological prototype of the CALICE highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) was tested in a beam at DESY in 2017. The setup comprised seven layers of silicon sensors. Each layer comprised four sensors,…
Hybrid ECAL is a cost-conscious option of electromagnetic calorimeter (ECAL) for particle flow calorimetry to be used in a detector of International Linear Collider (ILC). It is a combination of silicon-tungsten ECAL, which realizes high…
Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the…
Silicon pad sensors with novel functions of higher timing resolution (LGAD: Low Gain Avalanche Detector) and higher position resolution (PSD: Position Sensitive Detector) are studied for an application to Silicon-Tungsten electromagnetic…
This paper describes a comprehensive experimental study on viability and prospects for the measurement of electroweak observables in $e^{+}e^{-}\rightarrow b\bar{b}$ and $e^{+}e^{-}\rightarrow c\bar{c}$ processes at the International Linear…
SiD is a robust, silicon-based detector proposed for the International Linear Collider (ILC). SiD employs a sampling silicon-tungsten electromagnetic calorimeter (ECal) to accurately measure the energies of electrons, positrons, and photons…
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than…
In this article we describe the commissioning and a first analysis of the the beam test performance of a small prototype of a highly granular silicon tungsten calorimeter. The prototype features detector elements with a channel number…
A Forward Calorimeter (FoCal) has been proposed as part of the ALICE upgrades for data taking from 2029 onwards. The FoCal will feature a sampling electromagnetic calorimeter segmented into 110 towers supplemented by a hadron calorimeter.…
The International Linear Collider (ILC) is a proposed electron-positron collider with a center-of-mass energy of 500~GeV, and a peak luminosity of $2 \cdot 10^{34}~\mathrm{cm}^{-2}\mathrm{s}^{-1}$. The ILC will complement the Large Hadron…
We are developing position sensitive silicon detectors (PSD) which have an electrode at each of four corners so that the incident position of a charged particle can be obtained using signals from the electrodes. It is expected that the…
The SiD Detector is one of two detector designs for the future International Linear Collider (ILC) that were validated in 2012 SiD features a compact, cost-constrained design for precision Higgs and other measurements, and sensitivity to a…
The next major project of particle physics will be the International Linear Collider: a linear accelerator in which electrons and positrons will collide with energies of 500 to around 1000 billion electronvolts. The LPSC-Grenoble is…