Related papers: A Cryogenic Infrared Calibration Target
Brownian thermal noise of thin-film coatings is a fundamental limit for high-precision experiments based on optical resonators such as gravitational-wave interferometers. Here we present the results of a research activity aiming to develop…
Single-photon imaging spectrometers of high quantum efficiency in the infrared to ultraviolet wavelength range, with good timing resolution and with a vanishing dark count rate are on top of the wish list in earth-bound astronomy, material…
A normal metal - superconductor hybrid single-electron trap with tunable barrier is utilized as a tool for spectrum analysis at the extremely low signal levels, using only well filtered cryogenic microwave background as a photon source in…
In this work we present an elegant solution for a scintillation counter to be integrated into a cryogenic system. Its distinguishing feature is the absence of a continuous light guide coupling the scintillation and the photodetector parts,…
The last years have seen the first cryogenic detectors to be proposed for usage on balloon-borne missions. In such missions, the instrument will be exposed to the high radiation environment of the upper atmosphere. This radiation can induce…
The temperature dependence of the reflectance spectra of magnesium oxide (MgO) and ferropericlase (Mg1-xFexO, for x=0.06 and x=0.27) have been measured over a wide frequency range (~50 to 32000 cm-1) at 295 and 6 K. The complex dielectric…
The paper report new results of chromatic dispersion in Photonic Crystal Fibers (PCFs) through appropriate designing of index-guiding triangular-lattice structure devised, with a selective infiltration of only the first air-hole ring with…
By selecting short exposure images taken using a CCD with negligible readout noise we obtained essentially diffraction-limited 810 nm images of faint objects using nearby reference stars brighter than I=16 at a 2.56 m telescope. The FWHM of…
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Planck LFI Radiometer Chain Assemblies (RCAs) have been calibrated in two dedicated cryogenic facilities. In…
A novel photonic thermal diode concept operating in the near field and capitalizing on the temperature-dependence of coupled surface polariton modes in nanostructures is proposed. The diode concept utilizes terminals made of the same…
Crystalline silicon is currently being discussed as test-mass material for future generations of gravitational wave detectors that will operate at cryogenic temperatures. We present optical absorption measurements on a large-dimension…
We report on a novel calibration method of gaseous detectors using an internal \ce{^{37}Ar} source. The \ce{^{37}Ar} is a fast-decaying and low-energy calibration source that provides a mono-energetic peak of 2.82 keV. A gaseous…
Simple broadband microwave interconnects are needed for increasing the size of focal plane heterodyne radiometer arrays. We have measured loss and cross-talk for arrays of microstrip transmission lines in flex circuit technology at 297 and…
The scaling of superconducting nanowire-based devices to larger arrays is often limited by the cabling required to interface with each device. Cryogenic integrated circuits constructed from nanowire cryotrons, or nanocryotrons, can address…
In this paper we describe a new variant of null ellipsometry to determine thicknesses and optical properties of thin films on a substrate at cryogenic temperatures. In the PCSA arrangement of ellipsometry the polarizer and the compensator…
Cryogenic characterization and modeling of 0.18um CMOS technology (1.8V and 5V) are presented in this paper. Several PMOS and NMOS transistors with different width to length ratios(W/L) were extensively characterized under various bias…
We developed a broadband two-layer anti-reflection (AR) coating for use on a sapphire half-wave plate (HWP) and an alumina infrared (IR) filter for the cosmic microwave background (CMB) polarimetry. Measuring the faint CMB B-mode signals…
Typical materials for optical Kinetic Inductance Detetectors (KIDs) are metals with a natural absorption of 30-50% in the visible and near-infrared. To reach high absorption efficiencies (90-100%) the KID must be embedded in an optical…
As progress towards real implementations of cryogenic high gradient normal conducting accelerating cavities continues, a more mature understanding of the surface physics in this novel environment becomes increasingly necessary. To this end,…
We present two simple cryogenic RF ion trap systems in which cryogenic temperatures and ultra high vacuum pressures can be reached in as little as 12 hours. The ion traps are operated either in a liquid helium bath cryostat or in a low…