English
Related papers

Related papers: Scanning capacitance microscopy using a relaxation…

200 papers

In a linear tomosynthesis scanner designed for imaging histologic samples of several centimeter size at 10 micrometer resolution, the mechanical instability of the scanning stage (+/-10 micrometers) exceeded the resolution of the image…

Medical Physics · Physics 2022-09-05 Piroz Bahar , David Nguyen , Muyang Wang , Dumitru Mazilu , Eric E. Bennett , Han Wen

The metallic tip of a scanning force microscope operated at 300 mK is used to locally induce a potential in a fully controllable double quantum dot defined via local anodic oxidation in a GaAs/AlGaAs heterostructure. Using scanning gate…

Mesoscale and Nanoscale Physics · Physics 2011-06-20 Magdalena Huefner , Bruno Kueng , Stephan Schnez , Klaus Ensslin , Thomas Ihn , Matthias Reinwald , Werner Wegscheider

The microfluidic probe (MFP) is a non-contact, scanning microfluidic technology for local (bio)chemical processing of surfaces based on hydrodynamically confining nanoliter volumes of liquids over tens of micrometers. We present here a…

Tissues and Organs · Quantitative Biology 2014-08-19 J. F. Cors , R. D. Lovchik , E. Delamarche , G. V. Kaigala

The Scanning Tunneling Microscope (STM) is a powerful instrument to study electronic density of states at surfaces down to atomic scale. Many interesting samples require studying variations as a function of the magnetic field, which is most…

We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$\mu$m and a resolution of…

Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the…

We present a versatile and highly configurable scanning acoustic platform. This platform, comprising of a high frequency transducer, bespoke positioning system and temperature-regulated sample unit, enables the acoustic probing of materials…

Materials Science · Physics 2010-02-24 N G Parker , P V Nelson , M J W Povey

Micro- and nanomechanical resonators have emerged as promising platforms for sensing a broad range of physical properties such as mass, force, torque, magnetic field, and acceleration. The sensing performance relies critically on the…

The observation of quantum phenomena in macroscopic mechanical oscillators has been a subject of interest since the inception of quantum mechanics. Prerequisite to this regime are both preparation of the mechanical oscillator at low phonon…

Quantum Physics · Physics 2015-05-13 A. Schliesser , O. Arcizet , R. Rivière , T. J. Kippenberg

Soft x-ray microscopy plays an important role in modern spintronics. However, the achievable resolution of most x-ray magnetic imaging experiments is above 10 nm, limiting access to fundamental and technologically relevant length scales.…

We demonstrate a neutron tomography technique with sub-micrometer spatial resolution. Our method consists of measuring neutron diffraction spectra using a double crystal diffractometer as a function of sample rotation and then using a phase…

Instrumentation and Detectors · Physics 2020-11-13 B. Heacock , D. Sarenac , D. G. Cory , M. G. Huber , J. P. W. MacLean , H. Miao , H. Wen , D. A. Pushin

We predict ground state cooling of a micro-mechanical oscillator, i.e. a vibrating end-mirror of an optical cavity, by resonant coupling of mirror vibrations to a narrow internal optical transition of an ensemble of two level systems. The…

Quantum Physics · Physics 2015-05-13 C. Genes , H. Ritsch , D. Vitali

Quantum dot (QD) lay-outs are becoming more complex as the technology is being applied to more complex multi-QD structures. This increase in complexity requires improved capacitance modeling both for design and accurate interpretation of QD…

Cavity optoelectromechanical regenerative amplification is demonstrated. An optical cavity enhances mechanical transduction, allowing sensitive measurement even for heavy oscillators. A 27.3 MHz mechanical mode of a microtoroid was…

Instrumentation and Detectors · Physics 2012-07-02 Michael A. Taylor , Alex Szorkovszky , Joachim Knittel , Kwan H. Lee , Terry G. McRae , Warwick P. Bowen

Cavity-enhanced radiation-pressure coupling of optical and mechanical degrees of freedom gives rise to a range of optomechanical phenomena, in particular providing a route to the quantum regime of mesoscopic mechanical oscillators. A prime…

Quantum Physics · Physics 2008-07-18 G. Anetsberger , R. Rivière , A. Schliesser , O. Arcizet , T. J. Kippenberg

Soft-clamped silicon nitride membrane resonators reach coherence times tau in excess of 100 ms at milliKelvin bath temperatures. However, harnessing strong optomechanical coupling in dry dilution refrigerators remains challenging due to…

Quantum Physics · Physics 2023-12-05 Eric Planz , Xiang Xi , Thibault Capelle , Eric C. Langman , Albert Schliesser

At low temperatures, microwave cavities are often preferred for the readout and control of a variety of systems. In this paper, we present design and measurements on an optomechanical device based on a 3-dimensional rectangular waveguide…

Cavity-enhanced radiation pressure coupling between optical and mechanical degrees of freedom allows quantum-limited position measurements and gives rise to dynamical backaction enabling amplification and cooling of mechanical motion. Here…

Optomechanical transduction is demonstrated for nanoscale torsional resonators evanescently coupled to optical microdisk whispering gallery mode resonators. The on-chip, integrated devices are measured using a fully fiber-based system,…

Mesoscale and Nanoscale Physics · Physics 2013-05-14 P. H. Kim , C. Doolin , B. D. Hauer , A. J. R. MacDonald , M. R. Freeman , P. E. Barclay , J. P. Davis

A silicon microstrip detector (SSD) has been developed to have state of the art spatial resolution and a large sensitive area under stringent power constraints. The design incorporates three floating strips with their bias resistors…