Related papers: Energy measurement and fragment identification usi…
Edge-TCT and charge collection measurements with passive test structures made in LFoundry 150 nm CMOS process on p-type substrate with initial resistivity of over 3 k$\Omega$cm are presented. Measurements were made before and after…
We propose a setup enabling electron energy loss spectroscopy to determine the density of the electrons accumulated by an electro-positive dielectric in contact with a plasma. It is based on a two-layer structure inserted into a recess of…
A method for the calibration of a Silicon Position Sensitive Detector is described. From the combination of the signals collected at the ends of the resistive electrode, energy and angle of the hitting particle are reconstructed with a…
A new technique of elucidating $\beta$-decay schemes of isotopes with large density of states at low excitation energies has been developed, in which a Broad Energy Germanium (BEGe) detector is used in conjunction with coaxial hyper-pure…
One significant drawback of a spectroscopic ellipsometry (SE) technique is its time-consuming and often complicated analysis procedure necessary to assess the optical functions of thin-film and bulk samples. Here, to solve this inherent…
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated…
Single-electron detectors are a key component of electron microscopes and advanced electron optics experiments. We present a YAG:Ce scintillator-based single-electron detector with a spatial resolution of 1 micrometer at an electron energy…
The GERDA experiment located at the LNGS searches for neutrinoless double beta (0\nu\beta\beta) decay of ^{76}Ge using germanium diodes as source and detector. In Phase I of the experiment eight semi-coaxial and five BEGe type detectors…
The collected charge of two pad diodes is measured along the diode width using a 5:2 GeV electron beam at the DESY II beam test facility. The electron beam enters parallel to the readout electrode plane and perpendicular to the edge of the…
We observe signals for the decays psi(3770)--> X J/psi from data acquired with the CLEO detector operating at the CESR e^+e^- collider with sqrt{s}=3773 MeV. We measure the following branching fractions B(psi(3770)--> XJ/psi) and…
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent…
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors…
A challenge preventing successful inverse kinematics measurements with heavy nuclei that are not fully stripped is identifying and tagging the beam particles. For this purpose, the HEavy ISotope Tagger (HEIST) has been developed. HEIST…
225Ac is a valuable medical radionuclide for targeted alpha therapy, but 227Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace…
A new instrument for spot profile analysis of electron diffraction - SPA-LEED - has been set up. The instrument works either with a transparent phosphor screen for visual inspection of the pattern or in its main mode with a channeltron for…
We present an X-ray characterization of a fully depleted, 725 $\mu$m thick p-channel SiSeRO CCD. Measurements with a $^{55}$Fe source yield an energy resolution of $54 \pm 0.9$ eV ($14.6 \pm 0.25 e^{-}$) at 5.9 keV for single-pixel events,…
In beam test experiments have been carried out for particle identification using digital pulse shape analysis in a 500~$\mu$m thick Neutron Transmutation Doped (nTD) silicon detector with an indigenously developed FPGA based 12 bit…
Using an electron-positron collision data sample of 2.93 fb$^{-1}$ collected at a center-of-mass energy of $\sqrt{s}=3.773$ GeV with the BESIII detector, we present the first search for the radiative leptonic decay $D^{+} \rightarrow \gamma…
Using $4.5\, fb^{-1}$ of $e^+e^-$ collision data collected by the BESIII detector at center-of-mass energies between $4.600$ and $4.699\,GeV$, we search for the semileptonic decays $\Lambda_c^{+} \to \Sigma^{+} \pi^{-} e^+ \nu_e$ and…
The paper describes a new E-Delta-E detection module which includes a position-sensitive double-sided strip detector (DSSD) and a low-pressure pentane-filled Delta-E chamber for detection of Evaporation Residues (ER) in complete fusion…