English
Related papers

Related papers: Operation and performance of the CMS tracker

200 papers

The LHC machine at CERN finished its first year of pp collisions at a center of mass energy of 7 TeV. While the commissioning to exploit its full potential is still ongoing, there are plans to upgrade its components to reach instantaneous…

Instrumentation and Detectors · Physics 2011-03-22 Hans-Christian Kästli

During autumn 2008, the Silicon Strip Tracker was operated with the full CMS experiment in a comprehensive test, in the presence of the 3.8 T magnetic field produced by the CMS superconducting solenoid. Cosmic ray muons were detected in the…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

The ATLAS experiment at the LHC will replace its current inner tracker system for the HL-LHC era. 3D silicon pixel sensors are being considered as radiation-hard candidates for the innermost layers of the new fully silicon-based tracking…

Instrumentation and Detectors · Physics 2019-09-04 S. Terzo , M. Chmeissani , G. Giannini , S. Grinstein , M. Manna , G. Pellegrini , D. Quirion , D. Vazquez Furelos

While the tracking detectors of the ATLAS and CMS experiments have shown excellent performance in Run 1 of LHC data taking, and are expected to continue to do so during LHC operation at design luminosity, both experiments will have to…

For operation at the High Luminosity Large Hadron Collider (LHC), the ATLAS experiment is building a new all-silicon inner tracker (ITk). The production and testing of thousands of silicon pixel and strip modules is required to cover the…

Instrumentation and Detectors · Physics 2022-03-23 D. Hohov , A. Lounis , A. Falou , E. - L. Gkougkousis , A. Bassalat

The CMS inner pixel detector system is planned to be replaced during the first phase of the LHC luminosity upgrade. The plans foresee an ultra low mass system with four barrel layers and three disks on either end. With the expected increase…

Instrumentation and Detectors · Physics 2019-08-13 Carlotta Favaro

For the barrel part of the CMS pixel tracker about 800 silicon pixel detector modules are required. The modules are bump bonded, assembled and tested at the Paul Scherrer Institute. This article describes the experience acquired during the…

Instrumentation and Detectors · Physics 2008-11-26 S. König , Ch. Hörmann , R. Horisberger , B. Meier , T. Rohe , S. Streuli , R. Weber , H. Chr. Kästli , W. Erdmann

Detectors at future high energy colliders will face enormous technical challenges. Disentangling the unprecedented numbers of particles expected in each event will require highly granular silicon pixel detectors with billions of readout…

The ATLAS inner detector comprises three different sub-detectors: the pixel detector, the silicon strip tracker, and the transition-radiation drift-tube tracker. The Insertable $B$-Layer, a new innermost pixel layer, was installed during…

High Energy Physics - Experiment · Physics 2017-12-08 ATLAS Collaboration

The next upgrade of the Large Hadron Collider (LHC) is planned from 2026 when the collider will move to its High Luminosity phase (HL-LHC). The CMS detector needs to be substantially upgraded during this period to exploit the fourfold…

Instrumentation and Detectors · Physics 2023-02-01 Tamas Almos Vami , Morris Swartz

This thesis presents the work carried out in the testing of the ATLAS Phase-II Upgrade electronic systems in the future strips tracker after 2023, to be installed for operations in the HL-LHC period. The high luminosity and number of…

Instrumentation and Detectors · Physics 2017-07-27 Carlos García-Argos

A semiconductor tracker for muon scattering tomography is presented. The tracker contains silicon strip sensors with an $80\,\mu$m pitch, precision mechanics and integrated cooling. The electronic readout of the sensors is performed by a…

Instrumentation and Detectors · Physics 2018-10-30 F. Keizer , A. Gorbatch , M. A. Parker , C. Steer , S. A. Wotton

The Pixel Detector is the innermost part of the CMS Tracker. It therefore has to prevail in the harshest environment in terms of particle fluence and radiation. There are several mechanisms that may decrease the efficiency of the detector.…

Instrumentation and Detectors · Physics 2015-05-08 Márton Bartók

The strategies for and the performance of the CMS silicon tracking system alignment during the 2015-2018 data-taking period of the LHC are described. The alignment procedures during and after data taking are explained. Alignment scenarios…

Instrumentation and Detectors · Physics 2022-06-15 CMS Collaboration

The High Luminosity Large Hadron Collider (HL-LHC) at CERN is expected to collide protons at a center-of-mass energy of 14 TeV and to reach the unprecedented peak instantaneous luminosity of $7.5 \times 10^{34} \text{cm}^{-2} \text{s}^{-1}$…

Instrumentation and Detectors · Physics 2023-01-26 Sascha Liechti

The High Luminosity Upgrade of the LHC will require the replacement of the Inner Detector of ATLAS with the Inner Tracker (ITk) in order to cope with higher radiation levels and higher track densities. Prototype silicon strip detector…

The ATLAS Inner Tracker, the future innermost part of the ATLAS detector, is an all-silicon tracker composed of pixel and strip modules, designed to cope with the extreme conditions expected during High-Luminosity LHC runs. Thorough testing…

We report on the operation and performance of the ATLAS Semi-Conductor Tracker (SCT), which has been functioning for 3 years in the high luminosity, high radiation environment of the Large Hadron Collider at CERN. We also report on the few…

Instrumentation and Detectors · Physics 2019-08-13 Zhijun Liang

A prototype of the CMOS pixel sensor named SUPIX-1 has been fabricated and tested in order to investigate the feasibility of a pixelated tracker for a proposed Higgs factory, namely, the Circular Electron-Positron Collider (CEPC). The…

Instrumentation and Detectors · Physics 2022-01-05 L. Li , L. Zhang , J. N. Dong , J. Liu , M. Wang

The entire CMS silicon pixel detector will be replaced to operate at the High-Luminosity LHC. In this contribution, the new Tracker Endcap Pixel detector will be presented, focusing on a novel concept to provide both power and data…

Instrumentation and Detectors · Physics 2021-11-15 Arne Christoph Reimers
‹ Prev 1 3 4 5 6 7 10 Next ›