English
Related papers

Related papers: Development of large-area quadrant silicon detecto…

200 papers

This paper presents the design and results of detailed tests of a CMOS active pixel chip for charged particle detection with in-pixel charge storage for correlated double sampling and readout in rolling shutter mode at frequencies up to 25…

Instrumentation and Detectors · Physics 2016-11-17 Marco Battaglia , Jean-Marie Bussat , Devis Contarato , Peter Denes , Piero Giubilato , Lindsay E. Glesener

We present measurements of radioactive contamination in the high-resistivity silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search for dark matter particles. Novel analysis methods, which exploit the unique spatial…

A novel modular high-resolution charged-particle tracking detector design using $250\mu m$ diameter, round, scintillating fibers and SiPM arrays for readout is presented. The fiber modules consist of 8 layers of 128 fibers, mechanically sta…

Instrumentation and Detectors · Physics 2008-11-26 Henning Gast , Thomas Kirn , Gregorio Roper Yearwood , Stefan Schael

A novel composite, scintillating material intended for neutron detection and composed of small (1.5 mm) cubes of KG2-type lithium glass embedded in a matrix of scintillating plastic has been developed in the form of a 2.2 in.-diameter, 3.1…

Instrumentation and Detectors · Physics 2015-05-27 G. C. Rich , K. Kazkaz , H. P. Martinez , T. Gushue

The performance of a double sided silicon strip detector (DSSSD), used for position and energy detection of heavy ions, is reported. The analysis shows that the incomplete charge collection (ICC) and charge sharing (CS) effects of the DSSSD…

Instrumentation and Detectors · Physics 2015-06-16 J L Han , J B Ma , X G Cao , Q Wang , J S Wang , Y Y Yang , P Ma , M R Huang , S L Jin , X J Rong , Z Bai , F Fu , Q Hu , R F Chen , S W Xu , J B Chen , L Jin , Y Li , M H Zhao , H S Xu

Two closely spaced dangling bonds positioned on a silicon surface and sharing an excess electron are revealed to be a strong candidate for a charge qubit. Based on our study of the coherent dynamics of this qubit, its extremely high…

We present an approach to construct position-sensitive silicon detectors with an integrated cooling circuit. Tests on samples demonstrate that a very modest liquid flow very effectively cool the devices up to a power dissipation of over…

Instrumentation and Detectors · Physics 2016-08-03 L. Andricek , M. Boronat , J. Fuster , I. Garcia , P. Gomis , C. Marinas , J. Ninkovic , M. Perello Rosello , M. A. Villarejo , M. Vos

We demonstrate that individual electron-hole pairs are resolved in a 1 cm$^2$ by 4 mm thick silicon crystal (0.93 g) operated at $\sim$35 mK. One side of the detector is patterned with two quasiparticle-trap-assisted…

Detailed measurements of the electron performance of the ATLAS detector at the LHC are reported, using decays of the Z, W and J/psi particles. Data collected in 2010 at sqrt(s)=7 TeV are used, corresponding to an integrated luminosity of…

High Energy Physics - Experiment · Physics 2012-08-27 ATLAS Collaboration

Sensors for particle tracking detectors are required to provide a maximum active area in addition to fulfilling performance criteria concerning radiation hardness, charge collection and operating conditions (e.g. leakage current, depletion…

Instrumentation and Detectors · Physics 2025-05-16 Luise Poley , Ian Dyckes , Javier Fernandez-Tejero , Celeste Fleta , Dennis Sperlich , Miguel Ullan

Electron scattering on both neutral ($X$) and charged ($X^-$) excitons in quantum wells is studied theoretically. A microscopic model is presented, taking into account both elastic and dissociating scattering. The model is based on…

Condensed Matter · Physics 2009-11-07 G. Ramon , A. Mann , E. Cohen

Excellent jet energy measurement is important at the International Linear Collider (ILC) because most of interesting physics processes decay into multi-jet final states. We employ a particle flow method to reconstruct particles, hence…

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…

In this paper, different Silicon PhotoMultiplier (SiPM) sensors have been tested with charged particles to characterize the Cherenkov light produced in the sensor protection layer. A careful position scan of the SiPM response has been…

The detection of an electron bunch exiting a strong magnetic field can prove challenging due to the small mass of the electron. If placed too far from a solenoid's entrance, a detector outside the magnetic field will be too small to…

The SiD Detector is one of two detector designs for the future International Linear Collider (ILC) that were validated in 2012 SiD features a compact, cost-constrained design for precision Higgs and other measurements, and sensitivity to a…

Instrumentation and Detectors · Physics 2025-05-20 M. Breidenbach , J. E. Brau , P. Burrows , T. Markiewicz , M. Stanitzki , J. Strube , A. P. White

The International Large Detector (ILD) is a proposed detector for the International Linear Collider (ILC). It has been designed to achieve an excellent jet energy resolution by using Particle Flow Algorithms (PFA), which rely on the ability…

The barrel region of the CMS pixel detector will be equipped with ``n-in-n'' type silicon sensors. They are processed on DOFZ material, use the moderated p-spray technique and feature a bias grid. The latter leads to a small fraction of the…

In beam test experiments have been carried out for particle identification using digital pulse shape analysis in a 500~$\mu$m thick Neutron Transmutation Doped (nTD) silicon detector with an indigenously developed FPGA based 12 bit…

Instrumentation and Detectors · Physics 2018-05-09 K. Mahata , A. Shrivastava , J. A. Gore , S. K. Pandit , V. V. Parkar , K. Ramachandran , A. Kumar , S. Gupta , P. Patale