English
Related papers

Related papers: Experimental study of electric breakdowns in liqui…

200 papers

We report on the results of a high voltage test in liquid argon in order to measure its dielectric rigidity. Under stable conditions and below the boiling point, liquid argon was found to sustain a uniform electric field of 100 kV/cm,…

Instrumentation and Detectors · Physics 2014-01-14 F. Bay , C. Cantini , S. Murphy , F. Resnati , A. Rubbia , F. Sergiampietri , S. Wu

We present a study on the dependence of electric breakdown discharge properties on electrode geometry and the breakdown field in liquid argon near its boiling point. The measurements were performed with a spherical cathode and a planar…

Instrumentation and Detectors · Physics 2016-03-17 M. Auger , A. Blatter , A. Ereditato , D. Goeldi , S. Janos , I. Kreslo , M. Luethi , C. Rudolf von Rohr , T. Strauss , M. S. Weber

The proliferation of liquid argon time projection chamber detectors makes the characterization of the dielectric properties of liquid argon a critical task. To improve understanding of these properties, a systematic study of the breakdown…

Instrumentation and Detectors · Physics 2015-03-27 R. Acciarri , B. Carls , C. James , B. Johnson , H. Jostlein , S. Lockwitz , B. Lundberg , J. L. Raaf , R. Rameika , B. Rebel , G. P. Zeller , M. Zuckerbrot

We present a method to reach electric field intensity as high as 400 kV/cm in liquid argon for cathode-ground distances of several millimeters. This can be achieved by suppressing field emission from the cathode, overcoming limitations that…

Instrumentation and Detectors · Physics 2015-06-22 M. Auger , A. Ereditato , D. Goeldi , S. Janos , I. Kreslo , M. Luethi , C. Rudolf von Rohr , T. Strauss , T. Tolba , M. S. Weber

High voltage breakdown in liquid argon is an important concern in the design of liquid argon time projection chambers, which are often used as neutrino and dark matter detectors. We have made systematic measurements of breakdown voltages in…

Instrumentation and Detectors · Physics 2016-04-13 Sarah Lockwitz , Hans Jostlein

We report the measurement of longitudinal electron diffusion coefficients in liquid argon for electric fields between 100 and 2000 V/cm with a gold photocathode as a bright electron source. The measurement principle, apparatus, and data…

Voltages above a hundred kilo-volt will be required to generate the drift field of future very large liquid Argon Time Projection Chambers. The most delicate component is the feedthrough whose role is to safely deliver the very high voltage…

Instrumentation and Detectors · Physics 2017-03-24 C. Cantini , A. Gendotti , L. Molina Bueno , S. Murphy , B. Radics , C. Regenfus , Y-A. Rigaut , A. Rubbia , F. Sergiampietri , T. Viant , S. Wu

As noble liquid time projection chambers grow in size their high voltage requirements increase, and detailed, reproducible studies of dielectric breakdown and the onset of electroluminescence are needed to inform their design. The Xenon…

Instrumentation and Detectors · Physics 2020-01-29 L. Tvrznikova , E. P. Bernard , S. Kravitz , K. O'Sullivan , G. Richardson , Q. Riffard , W. L. Waldron , J. Watson , D. N. McKinsey

We characterized a sample of metal-oxide resistors and measured their breakdown voltage in liquid argon by applying high voltage (HV) pulses over a 3 second period. This test mimics the situation in a HV-divider chain when a breakdown…

We have constructed an apparatus to study DC electrical breakdown in liquid helium at temperatures as low as 0.4 K and at pressures between the saturated vapor pressure and $\sim$600 torr. The apparatus can house a set of electrodes that…

Designs of high-voltage (HV) systems for creating a drift electric field in liquid argon TPCs are reviewed. In ongoing experiments systems capable of approx. 100 kV are realised for a drift field of 0.5-1 kV/cm over a length of up to 1.5 m.…

Instrumentation and Detectors · Physics 2011-07-28 S. Horikawa , A. Badertscher , L. Kaufmann , M. Laffranchi , A. Marchionni , M. Messina , G. Natterer , A. Rubbia

We report results from a study on electrical breakdown in liquid helium using near-uniform-field stainless steel electrodes with a stressed area of $\sim$0.725 cm$^2$. The distribution of the breakdown field is obtained for temperatures…

Instrumentation and Detectors · Physics 2024-07-19 N. S. Phan , W. Wei , B. Beaumont , N. Bouman , S. M. Clayton , S. A. Currie , T. M. Ito , J. C. Ramsey , G. M. Seidel

This Letter details a measurement of the ionization yield ($Q_y$) of 6.7 keV $^{40}Ar$ atoms stopping in a liquid argon detector. The $Q_y$ of 3.6-6.3 detected $e^{-}/\mbox{keV}$, for applied electric fields in the range 240--2130 V/cm, is…

Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by…

Instrumentation and Detectors · Physics 2021-10-27 P. Abratenko , R. An , J. Anthony , J. Asaadi , A. Ashkenazi , S. Balasubramanian , B. Baller , C. Barnes , G. Barr , V. Basque , L. Bathe-Peters , O. Benevides Rodrigues , S. Berkman , A. Bhanderi , A. Bhat , M. Bishai , A. Blake , T. Bolton , L. Camilleri , D. Caratelli , I. Caro Terrazas , R. Castillo Fernandez , F. Cavanna , G. Cerati , Y. Chen , E. Church , D. Cianci , J. M. Conrad , M. Convery , L. Cooper-Troendle , J. I. Crespo-Anadon , M. Del Tutto , S. R. Dennis , D. Devitt , R. Diurba , R. Dorrill , K. Duffy , S. Dytman , B. Eberly , A. Ereditato , J. J. Evans , R. Fine , G. A. Fiorentini Aguirre , R. S. Fitzpatrick , B. T. Fleming , N. Foppiani , D. Franco , A. P. Furmanski , D. Garcia-Gamez , S. Gardiner , G. Ge , S. Gollapinni , O. Goodwin , E. Gramellini , P. Green , H. Greenlee , W. Gu , R. Guenette , P. Guzowski , L. Hagaman , E. Hall , P. Hamilton , O. Hen , G. A. Horton-Smith , A. Hourlier , R. Itay , C. James , X. Ji , L. Jiang , J. H. Jo , R. A. Johnson , Y. J. Jwa , N. Kamp , N. Kaneshige , G. Karagiorgi , W. Ketchum , M. Kirby , T. Kobilarcik , I. Kreslo , R. LaZur , I. Lepetic , K. Li , Y. Li , K. Lin , A. Lister , B. R. Littlejohn , W. C. Louis , X. Luo , K. Manivannan , C. Mariani , D. Marsden , J. Marshall , D. A. Martinez Caicedo , K. Mason , A. Mastbaum , N. McConkey , V. Meddage , T. Mettler , K. Miller , J. Mills , K. Mistry , T. Mohayai , A. Mogan , J. Moon , M. Mooney , A. F. Moor , C. D. Moore , L. Mora Lepin , J. Mousseau , M. Murphy , D. Naples , A. Navrer-Agasson , R. K. Neely , J. Nowak , M. Nunes , O. Palamara , V. Paolone , A. Papadopoulou , V. Papavassiliou , S. F. Pate , A. Paudel , Z. Pavlovic , E. Piasetzky , I. Ponce-Pinto , S. Prince , X. Qian , J. L. Raaf , V. Radeka , A. Rafique , M. Reggiani-Guzzo , L. Ren , L. C. J. Rice , L. Rochester , J. Rodriguez Rondon , H. E. Rogers , M. Rosenberg , M. Ross-Lonergan , G. Scanavini , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , R. Sharankova , J. Sinclair , A. Smith , E. L. Snider , M. Soderberg , S. Soldner-Rembold , P. Spentzouris , J. Spitz , M. Stancari , J. St. John , T. Strauss , K. Sutton , S. Sword-Fehlberg , A. M. Szelc , N. Tagg , W. Tang , K. Terao , C. Thorpe , D. Totani , M. Toups , Y. -T. Tsai , M. A. Uchida , T. Usher , W. Van De Pontseele , B. Viren , M. Weber , H. Wei , Z. Williams , S. Wolbers , T. Wongjirad , M. Wospakrik , N. Wright , W. Wu , E. Yandel , T. Yang , G. Yarbrough , L. E. Yates , G. P. Zeller , J. Zennamo , C. Zhang

We measure the liquid argon scintillation response to electronic recoils in the energy range of $2.82$ to $1274.6~{\rm keV}$ at null electric field. The single-phase detector with a large optical coverage used in this measurement yields…

Instrumentation and Detectors · Physics 2020-11-25 M. Kimura , K. Aoyama , M. Tanaka , K. Yorita

We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high…

Instrumentation and Detectors · Physics 2018-07-24 P. Agnes , I. F. M. Albuquerque , T. Alexander , A. K. Alton , D. M. Asner , M. P. Ave , H. O. Back , B. Baldin , G. Batignani , K. Biery , V. Bocci , G. Bonfini , W. Bonivento , M. Bossa , B. Bottino , F. Budano , S. Bussino , M. Cadeddu , M. Cadoni , F. Calaprice , A. Caminata , N. Canci , A. Candela , M. Caravati , M. Cariello , M. Carlini , M. Carpinelli , S. Catalanotti , V. Cataudella , P. Cavalcante , S. Cavuoti , A. Chepurnov , C. Cicalo , A. G. Cocco , G. Covone , D. D'Angelo , M. D'Incecco , D. D'Urso , S. Davini , A. De Candia , S. De Cecco , M. De Deo , G. De Filippis , G. De Rosa , M. De Vincenzi , P. Demontis , A. V. Derbin , A. Devoto , F. Di Eusanio , G. Di Pietro , C. Dionisi , E. Edkins , A. Fan , G. Fiorillo , K. Fomenko , D. Franco , F. Gabriele , A. Gabrieli , C. Galbiati , S. Giagu , C. Giganti , G. K. Giovanetti , A. M. Goretti , F. Granato , M. Gromov , M. Guan , Y. Guardinbcerri , M. Gulino , B. R. Hackett , K. Herner , D. Hughes , P. Humble , E. V. Hungerford , An. Ianni , I. James , T. N. Johnson , K. Keeter , C. L. Kendziora , G. Koh , D. Korablev , G. Korga , A. Kubankin , M. Kuss , X. Li , M. Lissia , B. Loer , G. Longo , Y. Ma , A. A. Machado , I. N. Machulin , A. Mandarano , S. M. Mari , J. Maricic , C. J. Martoff , A. Messina , P. D. Meyers , R. Milincic , A. Monte , M. Morrocchi , B. J. Mount , V. N. Muratova , P. Musico , A. Navrer Agasson , A. Nozdrina , A. Oleinik , M. Orsini , F. Ortica , L. Pagani , M. Pallavicini , L. Pandola , E. Pantic , E. Paoloni , F. Pazzona , K. Pelczar , N. Pelliccia , A. Pocar , S. Pordes , H. Qian , M. Razeti , A. Razeto , B. Reinhold , A. L. Renshaw , M. Rescigno , Q. Riffard , A. Romani , B. Rossi , N. Rossi , D. Sablone , O. Samoylov , W. Sands , S. Sanfilippo , M. Sant , C. Savarese , B. Schlitzer , E. Segreto , D. A. Semenov , A. Sheshukov , P. N. Singh , M. D. Skorokhvatov , O. Smirnov , A. Sotnikov , C. Stanford , G. B. Suffritti , Y. Suvorov , R. Tartaglia , G. Testera , A. Tonazzo , P. Trinchese , E. V. Unzhakov , M. Verducci , A. Vishneva , B. Vogelaar , M. Wada , T. J. Waldrop , S. Walker , H. Wang , Y. Wang , A. W. Watson , S. Westerdale , M. M. Wojcik , X. Xiang , X. Xiao , C. Yang , Z. Ye , C. Zhu , G. Zuzel

We describe the design and performance of a 260-liter liquid argon (LAr) cryogenic test stand for liquid argon detector research and development at BNL. The system uses gas-phase argon purification with continuous pump-free circulation, in…

Instrumentation and Detectors · Physics 2026-04-23 Yichen Li , Aleksey Bolotnikov , Milind Diwan , Jay Hyun Jo , Steven Kettell , Steven Linden , Xin Qian , Matteo Vicenzi , Chao Zhang

We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization…

Instrumentation and Methods for Astrophysics · Physics 2013-07-23 S. Sangiorgio , T. H. Joshi , A. Bernstein , J. Coleman , M. Foxe , C. Hagmann , I. Jovanovic , K. Kazkaz , K. Mavrokoridis , V. Mozin , S. Pereverzev , P. Sorensen

The purpose, design specifications, construction techniques, and testing methods are described for the high voltage feedthrough ports and filters of the ATLAS Liquid Argon calorimeters. These feedthroughs carry about 5000 high voltage wires…

Instrumentation and Detectors · Physics 2008-11-26 B. Botchev , G. Finocchiaro , J. Hoffman , R. L. McCarthy , M. Rijssenbeek , J. Steffens , A. Talalaevskii , M. Thioye , M. Zdrazil , J. Farrell , S. Kane

In this paper we describe the design, construction, and operation of a first large area double-phase liquid argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). The detector has a maximum drift length of 60 cm and the…

‹ Prev 1 2 3 10 Next ›