Related papers: Theoretical analysis of BLM system for HLS II
The new beam position monitor (BPM) system of the injector at the upgrade project of Hefei Light Source (HLS II) has 19 stripline beam position monitors. Most consist of four orthogonal symmetric stripline electrodes. The differences in…
The Beam Loss Monitors (BLM) are designed to measure the position and amount of beam loss in accelerators. In this article, we have studied the 3 GeV electron losses in the storage ring and secondary particles from the losses on the beam…
One of the main functions of the LHC beam loss measurement system is the protection of equipment against damage caused by impacting particles creating secondary showers and their energy dissipation in the matter. Reliability requirements…
As the brightness of synchrotron radiation (SR) light sources improves, the operation stability of light sources is weakened. To explore various beam instability related issues in light sources, one transverse beam diagnostics system for…
To meet the increasing requirements of synchrotron radiation users, the upgrade project to enhance the performance of Hefei Light Source (HLS), named HLS-II, was launched in 2010, and in 2014 the first commissioning of HLS-II was…
This contribution presents a novel bunch current measurement system based on an ultra-fast photodetector and a high-speed digitizer at Hefei Light Source II (HLS II). In order to achieve bunch-by-bunch resolution, the sampling rate of the…
HLS (Hefei Light Source) is a second generation synchrotron radiation source. After injected into the storage ring at energy of 200MeV, the electrons will be ramped to 800MeV. During ramping, the magnetic fields of the bend, quadruple and…
In the storage ring of PLS-II, we reduced mechanical displacement of electron beam position monitors (e-BPMs) that is caused by heating during e-beam storage. The orbit feedback system intends that the electron beam pass through the center…
A logarithm processing algorithm to measure beam transverse size and position is proposed and preliminary experimental results in Hefei Light Source II (HLS II) are given. The algorithm is based on only 4 successive channels of 16 anode…
By combining the LHC Beam Loss Monitoring (BLM) system with the LHC experiments, a powerful search machine for new physics beyond the standard model can be realised. The pair of final state protons in the central production process, exit…
The photon flux resulting from high-energy electron beam interactions with high field systems, such as in the upcoming FACET-II experiments at SLAC National Accelerator Laboratory, may give deep insight into the electron beam's underlying…
The beam energy measurement system (BEMS) for the upgraded Beijing electron-positron collider BEPC-II is described. The system is based on measuring the energies of Compton back-scattered photons. The relative systematic uncertainty of the…
An interferometer system and an imaging system using visible synchrotron radiation (SR) have been installed in HLS II storage ring. Simulations of these two systems are given using Synchrotron Radiation Workshop(SRW) code. With these two…
Possible parameters of Light Sources (LS) based on Backward Rayleigh Scattering (BRS) of laser photons on relativistic ion beams in storage rings are discussed. It was shown that the parameters of the LS based on the RHIC storage ring…
LHC upgrades are being considered both towards higher luminosity (HL-LHC) and towards higher energy (HE-LHC). In this paper we report initial studies of the beam-beam effects in the HE-LHC [1]. The HE-LHC aims at beam energies of 16.5 TeV,…
The upgrade project of Hefei Light Source storage ring is under way. In this paper, the wake fields of new designed vacuum chambers have been simulated by CST code, and then broadband impedances were obtained by FFT. Together with resistive…
Type II WLFs have weak Balmer line emission and no Balmer jump. We carried out a set of radiative hydrodynamic simulations to understand how the hydrogen radiative losses vary with the electron beam parameters and more specifically with the…
Beam loss is a critical issue in high-intensity accelerators, and much effort is expended during both the design and operation phases to minimize the loss and to keep it to manageable levels. As new accelerators become ever more powerful,…
A scheme with two superconducting RF cavities (sc-cavities) is designed to upgrade electron storage rings with odd buckets into multi-length bunches. In this paper, Hefei Light Source II (HLS II) is given as an example for odd buckets. In…
The beam energy measurement system is of great importance and profit for both BEPC-II accelerator and BES-III detector. The system is based on measuring the energies of Compton back-scattered photons. Many advanced techniques and precise…