English
Related papers

Related papers: A high-sensitivity push-pull magnetometer

200 papers

We discuss the design and performance of a laser-pumped cesium vapor magnetometer in the $M_x$-configuration. The device will be implemented for the control and stabilization of fluctuating magnetic fields and gradients in a new experiment…

Atomic Physics · Physics 2007-05-23 S. Groeger , J. -L. Schenker , R. Wynands , A. Weis

We report the design and performance of a non-magnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 s and 600 s. To our knowledge this…

Applied Physics · Physics 2022-05-04 M. Rosner , D. Beck , P. Fierlinger , H. Filter , C. Klau , F. Kuchler , P. Rößner , M. Sturm , D. Wurm , Z. Sun

We describe an ultra-sensitive atomic magnetometer using optically-pumped potassium atoms operating in spin-exchange relaxation free (SERF) regime. We demonstrate magnetic field sensitivity of 160 aT/Hz$^{1/2}$ in a gradiometer arrangement…

Atomic Physics · Physics 2015-05-14 H. B. Dang , A. C. Maloof , M. V. Romalis

We report the performance of a magnetically silent optically pumped cesium magnetometer with a statistical sensitivity of 3.5 pT/rtHz at 1~Hz and a stability of 90 fT over 150 seconds of measurement. Optical pumping with coherent,…

We present a novel approach allowing an optically pumped magnetometer (OPM) to be operated within Earth's magnetic field as a vector magnetometer whose sensitive axis can be freely defined. This approach enables the measurement of any…

Instrumentation and Detectors · Physics 2024-08-20 Thomas Schönau , Theo Scholtes , Florian Wittkämper , Alexander Sekels , Stefan Hiebel , Gregor Oelsner , Ronny Stolz

An atomic magnetometer operated with elliptically polarized light is investigated theoretically and experimentally. To explore the potential of this magnetometric configuration, the analytical form of the outgoing signal is derived.…

Atomic Physics · Physics 2020-01-08 Shengran Su , Guoyi Zhang , Xin Bi , Xiang He , Wenqiang Zheng , Qiang Lin

The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond…

For precision atomic magnetometry, inert buffer gas is included in alkali-metal vapor cells to significantly broaden hyperfine transitions, which facilitates optical pumping and reduces diffusive relaxation, while also providing…

Atomic Physics · Physics 2026-02-12 M. E. Limes , J. Smoot , J. Perez , J. Freeman , C. Amano-Dolan , D. Peters , W. Lee

We present a portable optically pumped magnetometer instrument for ultra-sensitive measurements within the Earth's magnetic field. The central part of the system is a sensor head operating a MEMS-based Cs vapor cell in the light-shift…

The operation of a high sensitive atomic magnetometer using resonant elliptically polarized light is demonstrated. The experimental geometry allows autonomous frequency stabilization of the laser, thereby offers compact operation of the…

Atomic Physics · Physics 2016-03-23 S. Pradhan , S. Mishra , R. Behera , Poornima , K. Dasgupta

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic…

Atomic Physics · Physics 2015-05-18 Chris Hovde , Brian Patton , Eric Corsini , James Higbie , Dmitry Budker

We describe and operate a novel spin-magnetometer based on the phase modulation of cavity magnon polaritons. In this scheme a rf magnetic field is detected through the sidebands it induces on a pump, and the experimental configuration…

Instrumentation and Detectors · Physics 2022-03-07 Nicolò Crescini , Giovanni Carugno , Giuseppe Ruoso

Optically-pumped magnetometers are an important instrument for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of…

Applied Physics · Physics 2024-04-12 Adil Meraki , Lucy Elson , Nok Ho , Ali Akbar , Marcin Koźbiał , Jan Kołodyński , Kasper Jensen

Magnetic resonance of sodium fluorescence is studied with varying laser intensity, duty cycle, and field strength. A magnetometer based on sodium vapor cell filled with He buffer gas is demonstrated, which uses a single amplitude-modulated…

Optics · Physics 2018-02-14 Tingwei Fan , Lei Zhang , Xuezong Yang , Shuzhen Cui , Tianhua Zhou , Yan Feng

We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in a cesium vapor. Vector capability is added by effective modulation of the field…

Atomic Physics · Physics 2015-06-19 B. Patton , E. Zhivun , D. C. Hovde , D. Budker

We have developed a versatile pulsed laser system for high precision magnetometry. The operating wavelength of the system can be configured to optically pump alkali vapors such as rubidium and cesium. The laser system consists of an…

Ultra-sensitive measurement of the magneto-optical rotation, due to interaction of linearly-polarized light passing through room-temperature Rb 85 atoms, in response to change in longitudinal magnetic field (\delta B_z ) is demonstrated…

Instrumentation and Detectors · Physics 2019-04-04 T. J. Vineeth Francis , Rashmi Ranjan Suna , P. K. Madhu , Nirmal K. Viswanathan , G. Rajalakshmi

Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout…

A magnetometric technique is demonstrated that may be suitable for precision measurements of fields ranging from the sub-microgauss level to above the Earth field. It is based on resonant nonlinear magneto-optical rotation caused by atoms…

Atomic Physics · Physics 2009-11-07 D. Budker , D. F. Kimball , V. V. Yashchuk , M. Zolotorev

Optically pumped magnetometers (OPMs) have demonstrated significant potential in weak magnetic field detection due to their high sensitivity. In this study, we developed an Mz-type optically pumped rubidium magnetometer using a…

Atomic Physics · Physics 2026-04-06 Zhengyu Su , Yang Li , Yongbiao Yang , Yanhua Wang , Jun He , Junmin Wang