English
Related papers

Related papers: Study of a high spatial resolution 10B-based therm…

200 papers

A new neutron detection concept is presented that is based on superconductive niobium (Nb) strips coated by a boron (B) layer. The working principle of the detector relies on the nuclear reaction 10B+n $\rightarrow$ $\alpha$+ 7Li , with…

Instrumentation and Detectors · Physics 2015-06-23 V. Merlo , M. Salvato , M. Cirillo , M. Lucci , I. Ottaviani , A. Scherillo , G. Celentano , A. Pietropaolo

The $^3$He(n,p) process is excellent for neutron detection between thermal and $\sim$4\,MeV because of the high cross section and near-complete energy transfer from the neutron to the proton. This process is typically used in gaseous forms…

Instrumentation and Detectors · Physics 2023-12-29 A. E. Sharbaugh , L. Jones , A. N. Villano

A high-efficiency fast neutron detector prototype based on a triple Gas Electron Multiplier (GEM) detector, which coupled with a novel multi-layered High-Density PolyEthylene (HDPE) as a neutron-to-proton converter for improving the neutron…

Instrumentation and Detectors · Physics 2015-06-19 Xiao-Dong Wang , He-Run Yang , Zhong-Guo Ren , Jun-Wei Zhang , Lei Yang , Chun-Hui Zhang , Ri-Ba-La Ha , Lv-Xing An

We report and discuss the first neutron reflection measurements from the free surface of normal and superfluid 4He and of liquid 3He-4He mixture. In case of liquid 4He the surface roughness is different above and below the lambda…

Other Condensed Matter · Physics 2008-11-20 T. R. Charlton , R. M. Dalgliesh , A. Ganshin , O. Kirichek , S. Langridge , P. V. E. McClintock

We present Monte Carlo (MC) simulation results from a study of a compact plastic-scintillator detector suitable for imaging fast neutrons in the 1 -- 10 MeV energy range: the miniTimeCube (mTC). Originally designed for antineutrino…

A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation,…

Instrumentation and Detectors · Physics 2014-11-24 T. J. Langford , C. D. Bass , E. J. Beise , H. Breuer , D. K. Erwin , C. R. Heimbach , J. S. Nico

This work builds on the previous introduction [1] of a coupled experimental-computational system devised to fully characterize the thermal behavior of complex 3D submicron electronic devices. The new system replaces the laser-based surface…

Materials Science · Physics 2007-09-13 Peter E. Raad , Pavel L. Komarov , M. Burzo

In this work we propose the application of an enhanced radiation damage model based on the introduction of deep level traps / recombination centers suitable for device level numerical simulation of silicon detectors at very high fluences…

Instrumentation and Detectors · Physics 2016-12-07 Daniele Passeri , Francesco Moscatelli , Arianna Morozzi , GianMario Bilei

We report on a comparison study of the $^{3}$He gas proportional tube and the $^{6}$Li incorporated scintillation glasses on thermal neutron detection efficiency. Both $^{3}$He and $^{6}$Li are used commonly for thermal neutron detection…

Instrumentation and Detectors · Physics 2015-06-15 Ming Xu , Zhi-Cheng Tang , Guo-Ming Chen , Jun-Quan Tao

Coherent elastic neutrino-nucleus scattering (CE$\nu$NS) offers a valuable approach in searching for physics beyond the Standard Model. The Ricochet experiment aims to perform a precision measurement of the CE$\nu$NS spectrum at the…

We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in…

While large neutrino telescopes have so far mainly focused on the detection of TeV-PeV astrophysical neutrinos, several efforts are ongoing to extend the sensitivity down to the GeV level for transient sources. Only a handful of neutrino…

High Energy Astrophysical Phenomena · Physics 2021-12-22 Gwenhaël de Wasseige

Neutron beam monitors with high efficiency, low gamma sensitivity, high time and space resolution are required in neutron beam experiments to continuously diagnose the delivered beam. In this work, commercially available neutron beam…

Instrumentation and Detectors · Physics 2017-10-04 F. Issa , A. Khaplanov , R. Hall-Wilton , I. Llamas , M. Dalseth Riktor , S. R. Brattheim , H. Perrey

An amplifier has been designed for optimal use of position sensitive thermal neutron detectors using the principle of resistive charge division. The important points in this optimization are: high counting rates and good spatial resolution.…

Instrumentation and Detectors · Physics 2009-11-13 Patrick Van Esch , Thomas Gahl , Bruno Guerard

Large liquid scintillation detectors have been generally dedicated to low energy neutrino measurements, in the MeV energy region (as for example, KamLAND and Borexino). Herein we describe the potential employment of large detectors (>1…

High Energy Physics - Experiment · Physics 2009-02-25 John G. Learned

A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in…

Instrumentation and Detectors · Physics 2017-09-20 B. B. Wiggins , Varinderjit Singh , J. Vadas , J. Huston , T. K. Steinbach , S. Hudan , R. T. deSouza

Two detection systems based on optical readout were developed: a. Integrative optical detector A 2nd generation of Time-Resolved Integrative Optical Neutron (TRION) detector was developed. It is based on an integrative optical technique,…

Instrumentation and Detectors · Physics 2017-05-01 Ilan Mor

A new instrument for high resolution imaging of fast-neutrons is presented here. It is designed for energy selective radiography in nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. The device presented here is based on hydrogenous…

This letter introduces a novel class of miniaturized, uncooled, and ultra-fast infrared (IR) resonant thermal detectors (RTDs) based on 30%-doped Aluminum Scandium Nitride (AlScN) nanoplates. Exploiting high electromechanical coupling, good…

Instrumentation and Detectors · Physics 2025-06-27 Aurelio Venditti , Walter Gubinelli , Enise F. Altin , Luca Colombo , Pietro Simeoni , Benyamin Davaji , Matteo Rinaldi

In the Energy Frontier we suggest developing high rate (100 MHz) finely segmented forward calorimetry preradiators with time resolution <50 ps which will survive the first 1-2 Lint of incident high radiation doses, protecting forward…

Instrumentation and Detectors · Physics 2022-03-21 David R Winn , Yasar Onel