English
Related papers

Related papers: Hamamatsu R1584 PMT Modifications

200 papers

A systematic investigation of Planacon MCP-PMTs was performed using 64 XP85002/FIT-Q photosensors. These devices are equipped with microchannel plates of reduced resistance. Results of a study of their gain stability over time and…

Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall…

CMS-HF Calorimeters have been undergoing a major upgrade for the last couple of years to alleviate the problems encountered during Run I, especially in the PMT and the readout systems. In this poster, the problems caused by the old PMTs…

Instrumentation and Detectors · Physics 2017-05-02 Erhan Gülmez

We discuss recent advances in the development of cryogenic gaseous photomultipliers (GPM), for possible use in dark matter and other rare-event searches using noble-liquid targets. We present results from a 10 cm diameter GPM coupled to a…

Instrumentation and Detectors · Physics 2015-10-28 L. Arazi , A. E. C. Coimbra , E. Erdal , I. Israelashvili , M. L. Rappaport , S. Shchemelinin , D. Vartsky , J. M. F. dos Santos , A. Breskin

The SABRE Experiment is a direct detection dark matter experiment using a target composed of multiple NaI(Tl) crystals. The experiment aims to be an independent check of the DAMA/LIBRA results with a detector in the Northern (Laboratori…

Aerogel and water Cerenkov detectors were employed to tag kaons for a lambda hypernuclear spectroscopic experiment which used the (e,e'K+) reaction in experimental Hall C at Jefferson Lab (JLab E05-115). Fringe fields from the kaon…

In this article we describe results of a photoelectron backscattering effect in vacuum phototubes: classical photomultipliers (PMT) and hybrid phototubes (PH). Late pulses occurring in PMTs are attributed to the photoelectron backscattering…

Instrumentation and Detectors · Physics 2009-11-11 B. K. Lubsandorzhiev , R. V. Vasiliev , Y. E. Vyatchin , B. A. J. Shaibonov

We report on the design and commissioning of two silica aerogel Cherenkov detectors with different refractive indices. In particular, extraordinary performance in terms of the number of detected photoelectrons was achieved through an…

The Large High-Altitude Air Shower Observatory (LHAASO) is being built at Haizi Mountain, Sichuan province of China at an altitude of 4410 meters. One of its main goals is to survey the northern sky for very-high-energy gamma ray sources…

Instrumentation and Detectors · Physics 2021-03-29 Kun Jiang , Zebo Tang , Xin Li , Zehua Cao , Cheng Li , Yang Li , Ziwei Li , Ziyang Li , Zheng Liang , Pengzhong Lu , Kaifeng Shen , Kaiyang Wang , Yan Wang , Xin Wu

The VSiPMT (Vacuum Silicon PhotoMultiplier Tube) is an original design for an innovative light detector we proposed with the aim to create new scientific instrumentation for industrial applications and physics research. The idea behind this…

Instrumentation and Detectors · Physics 2023-07-20 G. Barbarino , F. C. T. Barbato , C. M. Mollo , E. Nocerino , D. Vivolo

The performance of 16 and 64 channel photomultipliers coupled to scintillating fibres has been tested. The devices are sensitive to single photoelectrons, show little gain losses for magnetic fields up to 100 Gauss and have moderate optical…

Instrumentation and Detectors · Physics 2008-11-26 M. Enkelmann , U. Werthenbach , G. Zech , T. Zeuner

An experimental method to characterize the crosstalk and afterpulsing in silicon photomultipliers has been developed and applied to two detectors fabricated by Hamamatsu. An analytical model of optical crosstalk that we presented in a…

Instrumentation and Detectors · Physics 2015-12-09 Jaime Rosado , Víctor Manuel Aranda , Francisco Blanco , Fernando Arqueros

Photomultiplier tubes (PMTs) are used in Imaging Atmospheric Cherenkov Telescopes (IACTs) to detect Cherenkov light produced by air showers induced by gamma rays in the atmosphere. The afterpulsing rate of the PMTs for the Large-Sized…

In the framework of the development of the SWGO experiment we have performed a detailed study of the single unit of an extensive air shower observatory based on an array of water Cherenkov detectors. Indeed, one of the possible water…

Instrumentation and Methods for Astrophysics · Physics 2022-05-05 Francesca Bisconti , Andrea Chiavassa

Photomultiplier tubes (PMTs) are widely used in neutrino and other experiments for the detection of weak light. To date PMTs are the most sensitive single photon detector per unit area. In addition to the quantum efficiency for photon…

Instrumentation and Detectors · Physics 2019-09-23 Liang-Jian Wen , Miao He , Yi-Fang Wang , Jun Cao , Shu-Lin Liu , Yue-Kun Heng , Zhong-Hua Qin

Imaging air Cherenkov telescopes are usually triggered on a coincidence of two or sometimes more pixels, with discriminator thresholds in excess of 20 photoelectrons applied for each pixel. These thresholds required to suppress night-sky…

Astrophysics · Physics 2008-02-03 G. Hermann , C. Köhler , T. Kutter , W. Hofmann

A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array…

Instrumentation and Detectors · Physics 2015-06-03 L. Gruber , G. S. M. Ahmed , S. E. Brunner , P. Bühler , J. Marton , K. Suzuki

The current generation of Imaging Atmospheric Cherenkov Telescopes (IACTs), comprised of major installations such as the MAGIC telescopes, H.E.S.S. and VERITAS, is classified as the 3$^{\mathrm{rd}}$ generation of suchs instruments. These…

Instrumentation and Methods for Astrophysics · Physics 2023-10-02 Cornelia Arcaro , Michele Doro , Julian Sitarek , Dominik Baack

More target mass is required in current TPC based directional dark matter detectors for improved detector sensitivity. This can be achieved by scaling up the detector volumes, but this results in the need for more analogue signal channels.…

Instrumentation and Detectors · Physics 2018-03-14 A. C. Ezeribe , M. Robinson , N. Robinson , A. Scarff , N. J. C. Spooner , L. Yuriev

Silicon photomultiplier (SiPM), a new type of photosensor, is considered a substitute for traditional photomultiplier tube (PMT) in the next generation of dark matter and neutrino detectors, especially in noble gas detectors like liquid…

Instrumentation and Detectors · Physics 2023-05-31 T. A. Wang , C. Guo , X. H. Liang , L. Wang , M. Y. Guan , C. G. Yang , J. C. Liu , F. Y. Lin