Related papers: Hamamatsu R1584 PMT Modifications
ICARUS T600 will be operated as far detector of the Short Baseline Neutrino program at Fermilab (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line to search for a LSND-like sterile…
Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be…
Over 5,000 PMTs are being deployed at the South Pole to compose the IceCube neutrino observatory. Many are placed deep in the ice to detect Cherenkov light emitted by the products of high-energy neutrino interactions, and others are frozen…
Ultra-high-energy ($>$ 100 TeV) gamma-ray detection benefits from the use of muon detectors (MDs) thanks to their capability of suppressing the cosmic-ray background. More than 1100 8-inch photomultiplier tubes (PMTs), CR365-02-2 from…
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has…
Photomultiplier tubes (PMTs) are widely used in astroparticle physics experiments to detect light flashes (e.g. fluorescence or Cherenkov light) from extensive air showers (EASs) initiated by statistically rare very high energy cosmic…
This note describes a prototype particle tracking detector constructed with 1 mm plastic scintillating fibres with a 64 channel Hamamatsu H8500 flat-panel multi-anode photomultiplier readout. Cosmic ray tracks from an array of 11 gas-filled…
With the development of the Imaging Atmospheric Cherenkov Technique (IACT), Gamma-ray astronomy has become one of the most interesting and productive fields of astrophysics. Current IACT telescope arrays (MAGIC, H.E.S.S, VERITAS) use…
The 3-inch Hamamatsu R14374-02 photomultiplier tube is an improved version of the R12199-02 model and its successor in the construction of the KM3NeT neutrino telescope. A total of 1000 photomultipliers were analysed to assess their dark…
The MINOS long baseline neutrino oscillation experiment is comprised of three calorimeters, a Near Detector at FNAL, a Far Detector at the Soudan mine in northern Minnesota, and a Calibration Detector in a test beam at CERN. The light…
A new hybrid experiment has been constructed to measure the chemical composition of cosmic rays around the "knee" in the wide energy range by the Tibet AS$\gamma$ collaboration at Tibet, China, since 2014. They consist of a high-energy…
The detector for the MiniBooNE experiment at the Fermi National Accelerator Laboratory employs 1520 8 inch Hamamatsu models R1408 and R5912 photomultiplier tubes with custom-designed bases. Tests were performed to determine the dark rate,…
We are in the process of upgrading the VERITAS array of Cherenkov telescopes with new, high efficiency photomultipliers (PMT) that will considerably lower the energy threshold of the instrument and improve the overall sensitivity. The…
The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is…
The peak photon detection efficiency (PDE) of silicon photomultipliers (SiPMs) can be as good or better than the PDE of photomultiplier tubes (PMTs). There are experiments where the signal is measured in the presence of a strong, steady…
We report the long term performance of the photosensors, 143 one-inch R8520-406 and 37 three-inch R11410-MOD photomultipliers from Hamamatsu, in the first phase of the PandaX dual-phase xenon dark matter experiment. This is the first time…
Gamma-ray observations in the very-high-energy domain (E > 30 GeV) can exploit the imaging of few-nanosecond Cherenkov flashes from atmospheric particle showers. Photomultipliers have been used as the primary photosensors to detect…
The performance of a prototype Ring Imaging Cherenkov Detector is studied using a charged particle beam. The detector performance, using CF4 and air as radiators, is described. Cherenkov angle precision and photoelectron yield using hybrid…
The Probe for Luminosity Measurement detector is a novel luminometer designed to monitor the luminosity and beam conditions of the Large Hadron Collider at the interaction point of the LHCb experiment, starting from Run 3. The detector is…
The neutrino detector of the Jiangmen Underground Neutrino Observatory (JUNO) is designed to use 20 kilotons of liquid scintillator and approximately 16,000 20-inch photomultipliers (PMTs).One of the options is to use the 20-inch R12860 PMT…