English
Related papers

Related papers: Hamamatsu R1584 PMT Modifications

200 papers

The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint…

Hamamatsu photomultiplier tubes (PMT) and various PMT window materials were exposed to gamma irradiation. Tests were performed with absorbed doses of 1 krad and 120 krad. Initial recommendations on PMT types to use in the BTeV…

Instrumentation and Detectors · Physics 2007-05-23 A. Borisevich , V. Dormenev , G. Drobychev , A. Fyodorov , M. Korzhik , Y. Kubota , A. Lobko , A. Lopatik , O. Missevitch , V. Moroz

The new hemispherical photomultiplier tubes (PMTs) with 9 inch diameter from Hainan Zhanchuang Photonics Technology Co.,Ltd (HZC) have been studied. Narrow transit time spread (FWHM=2.35 ns) accompanied by small nonlinearity (750…

Hamamatsu single anode R7761 and multi-anode R5900-00-M16 Photomultiplier Tubes have been characterized for use in a Secondary Emission (SE) Ionization Calorimetry study. SE Ionization Calorimetry is a novel technique to measure…

Instrumentation and Detectors · Physics 2016-11-03 E. Tiras , K. Dilsiz , H. Ogul , D. Southwick , B. Bilki , J. Wetzel , J. Nachtman , Y. Onel , D. Winn

We have shown that high voltage biased Hamamatsu R11410-20 photomultipliers with a dark count rate above 10 kHz emit single photons. The effect has been observed in a few units at room temperature and temperatures reduced down to -60…

Instrumentation and Detectors · Physics 2015-12-09 D. Yu. Akimov , A. I. Bolozdynya , Yu. V. Efremenko , V. A. Kaplin , A. V. Khromov , Yu. A. Melikyan , V. V. Sosnovtsev

To fulfill the requirements for testing the photomultiplier tubes (PMTs) of the electromagnetic detec- tor at the Large High Altitude Air Shower Observatory (LHAASO), a multi-functional PMT test bench with a two dimensional scanning system…

Instrumentation and Detectors · Physics 2016-08-24 Xu Wang , Zhong-Quan Zhang , Ye Tian , Yan-Yan Du , Xiao Zhao , Fu-Wang Shen , Chang-Yu Li , Yansheng Sun , Cunfeng Feng

Since the early days of experimental particle physics photomultipliers (PMTs) have played an important role in the detector design. Thanks to their capability of fast photon counting, PMTs are extensively used in the new-generation of…

Instrumentation and Detectors · Physics 2016-08-24 C. Bozza , T. Chiarusi , M. Costa , F. Di Capua , V. Kulikovskiy , R. Mele , P. Migliozzi , C. M. Mollo , C. Pellegrino , G. Riccobene , D. Vivolo

The next-generation liquid xenon experiments like PandaX-xT target an energy range from sub-keV to multi-MeV to address the requirement of multiple physics searches. The Hamamatsu R12699-406-M4 photomultiplier tubes (PMTs) were developed…

Instrumentation and Detectors · Physics 2026-01-21 Houqi Huang , Peiyuan Chen , Ke Han , Yang Liu , Guanbo Wang , Shaobo Wang , Weihao Wu , Binbin Yan , Peihua Ye , Jiaxu Zhou , Zhizhen Zhou

Photo-multiplier tubes (PMTs) and silicon photo-multipliers (SiPMs) are detectors sensitive to single photons that are widely used for the detection of scintillation and Cerenkov light in subatomic physics and medical imaging. This paper…

Instrumentation and Detectors · Physics 2018-03-14 A. Butcher , L. Doria , J. Monroe , F. Retiere , B. Smith , J. Walding

The Milagro experiment observes the extensive air showers produced by very high energy gamma-rays impacting the Earth's atmosphere. Milagro uses 898 Hamamatsu R5912 Photomultiplier Tubes. To complete our Monte Carlo simulations, we tested…

Astrophysics · Physics 2007-11-14 V. Vasileiou , R. W. Ellsworth , A. J. Smith

Ton-scale liquid xenon detectors operated in two-phase mode are proposed and being constructed recently to explore the favored parameter space for the Weakly Interacting Massive Particles (WIMPs) dark matter. To achieve a better light…

Instrumentation and Detectors · Physics 2014-05-13 Y Wei , Q Lin , X Xiao , K Ni

In this paper, we present the design and characterization of a photosensor system developed for the RELICS experiment. An extended dynamic range base was designed to mitigate photomultiplier tube (PMT) saturation caused by intense cosmic…

We have investigated the response of a significant sample of Hamamatsu H8500 MultiAnode PhotoMultiplier Tubes (MAPMTs) as single photon detectors, in view of their use in a ring imaging Cherenkov counter for the CLAS12 spectrometer at the…

Instrumentation and Detectors · Physics 2015-03-25 M. Hoek , V. Lucherini , M. Mirazita , R. A. Montgomery , A. Orlandi , S. Anefalos Pereira , S. Pisano , P. Rossi , A. Viticchiè , A. Witchger

The water Cherenkov detector array (WCDA) for the large high altitude air shower observatory(LHAASO) will employ more than 3600 hemisphere 8 inch photomultiplier tubes (PMT). The good time performance of PMT, especially the transit time…

Instrumentation and Detectors · Physics 2014-09-05 W. P. Huang , Z. B. Tang , C. Li , K. Jiang , X. K. Zhao

The Hamamatsu R12699-406-M2 is a $2\times2$ multi-anode 2-inch photomultiplier tube that offers a compact form factor, low intrinsic radioactivity, and high photocathode coverage. These characteristics make it a promising candidate for…

Instrumentation and Detectors · Physics 2025-12-02 M. Adrover , L. Baudis , A. Bismark , A. P. Colijn , J. J. Cuenca-García , M. P. Decowski , M. Flierman , T. den Hollander

The 64-channel Multianode Photo Multiplier has been evaluated as a possible choice for the photo detectors of the LHCb Ring Imaging Cherenkov detector.

High Energy Physics - Experiment · Physics 2007-05-23 Franz Muheim

The Hamamatsu R5912-02Mod photomultiplier tube (PMT) will be used in the DUNE dual-phase module, a 10-kton fiducial volume liquid-argon time-projection chamber, which is one of the four projected far-detector modules of the DUNE…

We report on test results of a novel ring imaging Cherenkov (RICH) detection system consisting of a 3 meter long gaseous C4F8O radiator, a focusing mirror, and a photon detector array based on Hamamatsu multi-anode photomultiplier tubes.…

We investigated the use of Hamamatsu fine-mesh photomultiplier tube assemblies H6152-70 and H6614-70 with regards to their gain and timing resolution in magnetic fields up to 1.9 T. Our results show that the H6614-70 assembly can operate…

Instrumentation and Detectors · Physics 2016-06-22 V. Sulkosky , L. Allison , C. Barber , T. Cao , Y. Ilieva , K. Jin , G. Kalicy , K. Park , N. Ton , X. Zheng