We study the performance of two-phase avalanche detectors based on Gas Electron Multipliers (GEMs) and operated in an electron-avalanching mode in Ar and Xe. Emission, gain, energy resolution and stability characteristics of the detectors…
A MicroCAT (Micro Compteur A Trous) structure which is used for avalanche charge multiplication in gas filled radiation detectors has been optimised with respect to maximum electron transparency and minimum ion feedback. We report on the…
The dependence of the avalanche charge gain in Thick Gas Electron Multipliers (THGEM) on the purity of Ne, Ar and Xe filling gases was investigated. The gain, measured with alpha-particles in standard conditions (atmospheric pressure, room…
The gas gain and energy resolution of single and double THGEM detectors (5{\times}5cm2 effective area) with mini-rims (rim is less than 10{\mu}m) were studied. The maximum gain can reach 5{\times}103 and 2{\times}105 for single and double…
Two-phase Cryogenic Avalanche Detectors (CRADs) with GEM and THGEM multipliers have become an emerging potential technique for charge recording in rare-event experiments. In this work we present the performance of two-phase CRADs operated…
We present the results of our recent studies of a Thick Gaseous Electron Multiplier (THGEM)-based detector, operated in Ar, Xe and Ar:Xe (95:5) at various gas pressures. Avalanche-multiplication properties and energy resolution were…
A thick gas electron multiplier is considered for radiation-hard detectors (hadron calorimeter). There was carried out technological and design study to optimize the element structure. The measurements results and the next plans are…
Gas electron Multipliers (GEM) are a new generation of gaseous avalanche devices in the Micro Patterned Gaseous Detector category. GEMs are widely used in both nuclear and high energy experiments as well as in medical science. Several…
The performances of THGEM multipliers in two-phase Xe avalanche mode are presented for the first time. Additional results on THGEM operation in gaseous Xe at cryogenic temperatures are provided. Stable operation of a double-THGEM multiplier…
Thick GEM-like (THGEM) electrodes are robust, high gain gaseous electron multipliers, economically-manufactured by standard drilling and etching of thin printed circuit board or other materials. Their operation and structure are similar to…
THGEMs (THick Gas Electron Multiplier) of varying thickness, hole diameter and hole pitch have been studied. For a thinner-THGEM of thickness 0.2 mm, with hole diameter 0.2 mm, pitch 0.2 mm and narrow (5-10 {\mu}m) rim, the performance of…
Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve…
Combustion instabilities are particularly problematic for rocket thrust chambers because of their high energy release rates and their operation close to the structural limits. In the last decades, progress has been made in predicting high…
We report on the systematic study of a single-gas-electron-multiplication (GEM) loaded gaseous detector developed for precision measurements of high-energy particle beams and dose-verification measurements. In the present study, a…
A thick gas electron multiplier (THGEM) chamber with an effective readout area of 10$\times$10 cm$^{2}$ and a 11.3 mm ionization gap has been tested along with two regular gas electron multiplier (GEM) chambers in a cosmic ray test system.…
We study the mechanism of instability in transition edge sensor (TES) bolometers used for ground based observations of the Cosmic Microwave Background (CMB) at 270GHz. The instability limits the range of useful operating resistances of the…
Discharge probability in GEM-based gaseous detectors has been numerically estimated using an axisymmetric hydrodynamic model. Initial primary charge configurations in the drift region, obtained using Heed and Geant4, are found to have…
Motivated by the need for fast timing detectors to withstand up to 2 MGy of ionizing dose at the High Luminosity Large Hadron Collider, prototype low gain avalanche detectors (LGADs) have been fabricated in single pad configuration, 2x2…
The characteristic properties of two-phase Ar avalanche detectors, including those obtained with CsI photocathode, are further studied. Such detectors are relevant in the field of coherent neutrino-nucleus scattering and dark matter search…
We show that physics of multi-GEM structures is rather complex, regarding the number of phenomena affecting detector performance. The high-pressure operation in noble gases and the ion feedback are considered in more detail. It is proposed…