Related papers: Miniature Dilatometer Based upon an AFM Piezocanti…
We report penetration depth and resistivity measurements on the heavy fermion superconductor CeCoIn_5 using a self resonant tank circuit based on a tunnel diode oscillator. For magnetic fields applied near parallel to the \emph{ab}-planes…
There is a growing demand for experiments on calorimetric and thermal transport measurements at ultra-low temperatures below 1 mK and high magnetic fields up to 16 T. Particularly, milligram-sized solid samples are of great interest. We…
Levitated ferromagnetic systems are expected to have significant potential in precision magnetic field sensing by leveraging mechanical isolation to minimize mechanical contact and associated noise. Here, we report the implementation of a…
The electromagnetic calorimeter for the new muon (g-2) experiment at Fermilab will consist of arrays of PbF2 Cherenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here on measurements and simulations…
A biaxial tensile device for the transport study of layered materials is described. The device is mounted on the standard 24 pin zero force connector and can be moved between various setups. The compact design of the device makes it…
We introduce a contactless technique for probing superconductivity, metal-insulator transitions, and magnetic ordering in micron-sized samples under extreme pressure. Utilizing a multistage Lenz lens system, directly sputtered onto diamond…
A capacitive displacement system was constructed to measure the electric-field-induced piezoelectric strain in the simple form of either a bulk or thin film. The system can determine an AC displacement of 2 pm precisely by using a lock-in…
An AC susceptometer operating in the range of 10 Hz to 100 kHz and at room temperature is designed, built, calibrated and used to characterize the magnetic behaviour of coated magnetic nanoparticles. Other weakly magnetic materials (in…
We report the design and development of a piezoelectric sample rotation system, and its integration into an Oxford Instruments Kelvinox 100 dilution refrigerator, for orientation-dependent studies of quantum transport in semiconductor…
We introduce a new image cytometer design for detection of very small particulate and demonstrate its capability in water analysis. The device is a compact microscope composed of off the shelf components, such as a light emitting diode…
Compact X-rays detectors made of 1/2 inch Ce:LaBr3 crystals of cubic shape with SiPM array readout have been developed for the FAMUexperiment at RIKEN-RAL, to instrument regions of difficult access. Due to the high photon yield of Ce:LaBr3…
While dimuonium $(\mu^+\mu^-)$ has not yet been observed, it is of utmost fundamental interest. By virtue of the larger mass, dimuonium has greater sensitivity to beyond the standard model effects than its cousins positronium or muonium,…
Field-angle dependent specific heat measurement has been done on the heavy-fermion superconductor CeCoIn5 down to ~ 0.29 K, in a magnetic field rotating in the tetragonal c-plane. A clear fourfold angular oscillation is observed in the…
Enabling temperature dependent experiments in Atomic Force Microscopy is of great interest to study materials and surface properties at the nanoscale. By studying Curie temperature of multiferroic materials, temperature based phase…
Applying the Amplitude Difference method to Fermilab experiment E791 D+ -> pi-pi+pi+ data, we measure the low mass pi+pi- phase motion. Our results suggest a significant phase variation, compatible with the existence of an isoscalar…
The Simons Observatory is building both large (6 m) and small (0.5 m) aperture telescopes in the Atacama desert in Chile to observe the cosmic microwave background (CMB) radiation with unprecedented sensitivity. Simons Observatory…
Piezoelectric quartz tuning forks are investigated in view of their use as force sensors in dynamic mode scanning probe microscopy at temperatures down to 1.5 K and in magnetic fields up to 8 T. The mechanical properties of the forks are…
Accurate measurements of the nanoscale electromechanical coupling in materials, including piezo and ferroelectrics, twisted 2D layers, and biological systems is of both fundamental scientific and applied importance. Piezoresponse Force…
We report the design and operation of a versatile tunnel diode oscillator for high sensitivity (50 ppb) measurements of the magnetic susceptibility of samples over a wide temperature range (1.7-100 K) that can be used with a simple liquid…
We have succeeded in growing single crystals of the heavy-fermion superconductor CeCo(In1-xZnx)5 with x<=0.07. Measurements of specific heat, electrical resistivity, dc magnetization and ac susceptibility revealed that the superconducting…