Related papers: Novel Compact Accelerator-Based Neutron and Gamma …
A Geant4-based Python/C++ simulation and coding framework, which has been developed and used in order to aid the R&D efforts for thermal neutron detectors at neutron scattering facilities, is described. Built upon configurable geometry and…
A new neutron detector based on Micromegas technology has been developed for the measurement of the simulated neutron spectrum in the ADS project. After the presentation of simulated neutron spectra obtained in the interaction of 140 MeV…
A prototype device capable of moving a radioactive calibration source to multiple positions was operated at millikelvin temperatures using a modified commercial stepper motor. It was developed as an in-situ calibration strategy for…
A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation,…
We describe the results of detailed 3-D Monte Carlo simulations of a "CZT calorimeter" that can be used to detect photons in the keV to several MeV range. Several astrophysics applications require the detection of photons in the energy…
A method for calibration of cryogenic liquid argon detector response to recoils with certain energy -8.2 keV - is proposed. The method utilizes a process of inelastic scattering of monoenergetic neutrons produced by fusion DD neutron…
We review detector technologies which are currently considered for ultimate nucleon decay searches, new generation astrophysical neutrinos studies, and for future long-baseline neutrino experiments at new high-intensity neutrino beam…
In the frame of direct dark matter search, the fast neutrons producing elastic collisions are the ultimate background. The MIMAC (MIcro-tpc MAtrix Chambers) project has developed a directional detector providing the directional signature to…
In this article, a detailed investigation has been done for the long lived gamma activity due to neutron emitting experiments. These calculations mainly focused on the experiments used for energy calibration purposes. Calibrated energy is…
A neutron detector based on EJ301 liquid scintillator has been employed at EAST to measure the neutron energy spectrum for D-D fusion plasma. The detector was carefully characterized in different quasi-monoenergetic neutron fields generated…
The conceptual design and operational principle of a novel high-efficiency, fast neutron imaging detector based on THGEM, intended for future fan-beam transmission tomography applications, is described. We report on a feasibility study…
According to many dark matter models, a potential signal registered in a detector would feature a single-scattering nuclear recoil (NR). So, it is crucial to calibrate the detector's response to NR events. The conventional calibrations…
There is currently a big effort put into the operation and construction of world class neutron scattering facilities (SNS and SNS-TS2 in the US, J-PARC in Japan, ESS in Europe, CSS in China, PIK in Russia). On the other hand, there exists a…
European Spallation Source instruments like the macromolecular diffractometer, NMX, require an excellent neutron detection efficiency, high-rate capabilities, time resolution, and an unprecedented spatial resolution in the order of a few…
In the present article we describe the calibration measurements of the compact neutron spectrometer at certified PTB neutron source. The spectrometer is based on two diamond detectors enclosing the Li-6 neutron converter. The incident…
The electromagnetic properties of neutrinos, which are either trivial or negligible in the context of the Standard Model, can probe new physics and have significant implications in astrophysics and cosmology. The current best direct limits…
Neutrino cross sections are a critical ingredient in experiments that depend on neutrino scattering to reconstruct event kinematics and infer neutrino characteristics, like NOvA and T2K. An opportunity exists to reduce the 5-10% broad…
A new design of a detector module of submillimeter thickness for an electromagnetic calorimeter is presented. It is aimed to be used in the luminometers LumiCal and BeamCal in future linear e$^{+}$e$^{-}$ collider experiments. The module…
Next-generation xenon detectors with multi-ton-year exposure are powerful direct probes of dark matter candidates, in particular the favorite weakly-interacting massive particles. Coupled with the features of low thresholds and backgrounds,…
GN-Vision is a compact, dual-modality imaging device designed to simultaneously localize the spatial origin of $\gamma$-ray and slow neutron sources, with potential applications in nuclear safety, security, and hadron therapy. The system…