Related papers: Casimir interaction at liquid nitrogen temperature…
We performed measurements of the gradient of the Casimir force between Au-coated surfaces of a sphere and a plate by means of significantly upgraded dynamic atomic force microscope (AFM) based technique. By introducing combined cleaning…
We present complete results of the experiment on measuring the Casimir force between an Au-coated sphere and an untreated or, alternatively, UV-treated indium tin oxide film deposited on a quartz substrate. Measurements were performed using…
We present supplementary information on the recent indirect measurement of the Casimir pressure between two parallel plates using a micromachined oscillator. The equivalent pressure between the plates is obtained by means of the proximity…
We perform detailed comparison of the experimental data of the experiment on the determination of the Casimir pressure between two parallel Au plates with the theoretical values computed using the Lifshitz formula at zero temperature.…
Quantum theory predicts the existence of the Casimir force between macroscopic bodies, due to the zero-point energy of electromagnetic field modes around them. This quantum fluctuation-induced force has been experimentally observed for…
We propose a universal experiment to measure the differential Casimir force between a Au-coated sphere and two halves of a structured plate covered with a P-doped Si overlayer. The concentration of free charge carriers in the overlayer is…
We report precision measurements of the Casimir interaction at larger separation distances between the Au-coated surfaces of a sphere and a plate in ultrahigh vacuum using a much softer cantilever of the dynamic atomic force…
We describe a Casimir apparatus based on a differential force measurement between a Au-coated sphere and a planar slab divided in two regions, one of which is made of high-resistivity (dielectric) Si, and the other of Au. The crucial…
The Casimir effect, reflecting quantum vacuum fluctuations in the electromagnetic field in a region with material boundaries, has been studied both theoretically and experimentally since 1948. The forces between dielectric and metallic…
We report an improved precision measurement of the Casimir force. The force is measured between a large Al coated sphere and flat plate using an Atomic Force Microscope. The primary experimental improvements include the use of smoother…
A measurement of the Casimir force between a gold coated sphere and two Si plates of different carrier densities is performed using a high vacuum based atomic force microscope. The results are compared with the Lifshitz theory and good…
The gradient of the Casimir force between a Si-SiO${}_2$-graphene substrate and an Au-coated sphere is measured by means of a dynamic atomic force microscope operated in the frequency shift technique. It is shown that the presence of…
A recent experiment [J.L. Garrett et al., Phys. Rev. Lett {\bf 120}, 040401 (2018)] measured for the first time the gradient of the Casimir force between two gold spheres at room temperature. The theoretical analysis of the data was carried…
We describe experimental and related theoretical work on the measurement of the Casimir force using semiconductor test bodies. This field of research started in 2005 and several important and interesting results have already been obtained.…
We propose a test on the role of relaxation properties of conduction electrons in the Casimir pressure between two parallel metal-coated plates kept at different temperatures. It is shown that for sufficiently thick metallic coatings the…
The Casimir interaction between two thick parallel plates, one made of metal and the other of dielectric, is investigated at nonzero temperature. It is shown that in some temperature intervals the Casimir pressure and the free energy of a…
We study the Casimir pressure between two similar plates of finite thickness kept at different temperatures in the case when the dielectric permittivity of the plates depends on temperature. It is suggested to consider the dielectric…
In view of the increasing accuracy of Casimir experiments, there is a need for performing accurate theoretical calculations. Using accurate experimental data for the permittivities we present, via the Lifshitz formula applied to the…
We have used an atomic force microscope to make precision measurements of the Casimir force between a metallized sphere of diameter 196 microns and flat plate. The force was measured for plate-sphere separations from 0.1 to 0.9 microns. The…
The measurement of the Casimir force between a large gold coated sphere and single crystal silicon plate is performed with an atomic force microscope. A rigorous statistical comparison of data with theory is done, without use of the concept…