English
Related papers

Related papers: Ellipsometry with polarisation analysis at cryogen…

200 papers

Polarized neutrons are a powerful probe to investigate magnetism in condensed matter on length scales from single atomic distances to micrometers. With the ongoing advancement of neutron optics, that allow to transport beams with increased…

Instrumentation and Detectors · Physics 2017-08-02 Jochen Stahn , Artur Glavic

Several on-going and future experiments use a Stokes polarimeter (i.e. a rotating wave plate followed by a steady polarizer and by an unpolarized detector) to measure the small polarized component of the Cosmic Microwave Background. The…

Instrumentation and Methods for Astrophysics · Physics 2010-06-17 Maria Salatino , Paolo de Bernardis

Predictable circuit response is a critical prerequisite for accurate electronic measurements. We describe a powerful, yet straightforward, experimental method and analysis model that utilizes an affordable LCR meter in conjunction with an…

Instrumentation and Detectors · Physics 2025-06-17 Riley J. Carpenter , Jadyn Anczarski , Ivar Rydstrom , Aviv Simchony , Zoe J. Smith , Noah A. Kurinsky , Betty A. Young

The problem of imaging materials with circular polarization properties is discussed within the framework of vectorial ptychography. We demonstrate, both theoretically and numerically, that using linear polarizations to investigate such…

Optics · Physics 2023-10-04 Patrick Ferrand , Michel Mitov

We present results from cryogenic tests of a Volume-Phase Holographic (VPH) grating at 200 K measured at near-infrared wavelengths. The aims of these tests were to see whether the diffraction efficiency and angular dispersion of a VPH…

We present a procedure for fitting an ellipse to powder diffraction patterns recorded on a planar 2D detector, which uses the peak intensities as weights. This procedure works for complete and spotty diffraction rings. We outline all the…

Materials Science · Physics 2013-11-22 Michael L. Hart , Michael Drakopoulos

We report the uniaxial anisotropic optical constants of Wurtzite type AlN films deposited on Si (100) substrate using DC reactive magnetron sputtering as a function of growth temperature (Ts, 35 to 600 C). Evolution of optical properties…

Materials Science · Physics 2018-05-16 Padmalochan Panda , R. Ramaseshan , S. Tripura Sundari , H. Suematsu

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 - 540 GHz frequency range. EXCLAIM uses…

We present the design and operation of a fiber-based cryogenic confocal microscope. It is designed as a compact cold-finger that fits inside the bore of a superconducting magnet, and which is a modular unit that can be easily swapped…

Mesoscale and Nanoscale Physics · Physics 2015-05-20 Maksym Sladkov , M. P. Bakker , A. U. Chaubal , D. Reuter , A. D. Wieck , C. H. van der Wal

The PVLAS experiment operates an ellipsometer which embraces a superconducting dipole magnet and can measure ellipticity and rotation induced by the magnetic field onto linearly polarized light. The sensitivity of the instrument is about…

High Energy Physics - Experiment · Physics 2007-05-23 PVLAS Collaboration , E. Zavattini

We present the design and commissioning of a cryogenic low-vibration test facility that measures displacement noise from a gram-scale silicon cantilever at the level of 10$^{-16}\, \mathrm{m/\sqrt{Hz}}$ at 1kHz. A volume of $\sim$36 litres…

Instrumentation and Detectors · Physics 2025-08-28 D. P. Kapasi , T. G. McRae , J. Eichholz , P. A. Altin , D. E. McClelland , B. J. J. Slagmolen

Entropy stabilization has garnered significant attention as a new approach to designing novel materials. Much of the work in this area has focused on bulk ceramic processing, leaving entropy-stabilized thin films relatively underexplored.…

Materials Science · Physics 2020-06-29 Valerie Jacobson , Dave Diercks , Bobby To , Andriy Zakutayev , Geoff Brennecka

Two types of room temperature detectors of terahertz laser radiation have been developed which allow in an all-electric manner to determine the plane of polarization of linearly polarized radiation and the Stokes parameters of elliptically…

Alternating layers of granular Iron (Fe) and Titanium dioxide (TiO$_{2-\delta}$) were deposited on (100) Lanthanum aluminate (LaAlO$_3$) substrates in low oxygen chamber pressure using a controlled pulsed laser ablation deposition…

Materials Science · Physics 2007-05-23 Soack Dae Yoon , Carmine Vittoria , Vincent G. Harris , Allan Widom

We present the use of a commercially available fixed-angle multi-wavelength ellipsometer for quickly measuring the thickness of NbN thin films for the fabrication and performance improvement of superconducting nanowire single photon…

Applied Physics · Physics 2019-04-24 Owen Medeiros , Marco Colangelo , Ilya Charaev , Karl K Berggren

The development of ferromagnet/heavy metal thin-film structures, such as CoFeB/Mo, with spin-orbit interaction requires advanced methods for their production and study. Polarized neutron reflectometry (PNR) provides unique insights into the…

Vibrations in cryocoolers are a recurrent concern to the end user. They appear in different parts of the acoustic spectrum depending on the refrigerator type, Gifford McMahon or pulse-tube, and with a variable coupling strength to the…

Instrumentation and Detectors · Physics 2019-04-05 Anne Louchet-Chauvet , Rose Ahlefeldt , Thierry Chanelière

We present a new design of highly specialized small storage rings for low energy polarized electron beams. The new design is based on the transparent spin methodology that cancels the spin precession due to the magnetic dipole moment at any…

Accelerator Physics · Physics 2023-08-09 R. Suleiman , V. S. Morozov , Ya. S. Derbenev

By knowing the phase and modules of the reflection coefficient in neutron reflectometry problems, a unique result for the scattering length density (SLD) of a thin film can be determined which will lead to the exact determination of type…

Materials Science · Physics 2011-08-30 Saeed S. Jahromi , Seyed Farhad Masoudi

The applicability of standard methods for compositional analysis is limited for H-containing films. Neutron reflectometry is a powerful, non-destructive method that is especially suitable for these systems due to the large negative…