Related papers: GeFRO: a New Charge Sensitive Amplifier Design wit…
Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detection technology that can, in principle, provide significantly greater responsivity and improved noise performance than traditional charge coupled device (CCD)…
The upgrade of the Resistive Plate Chamber (RPC) detector, in order to increase the detector rate capability and to be able to work efficiently in high rate environment, consists in the reduction of the operating voltage along with the…
The first generation of Single electron Sensitive Read Out (SiSeRO) amplifiers, employed as on-chip charge detectors for charge-coupled devices (CCDs) have demonstrated excellent noise and spectral performance: a responsivity of around 800…
A well-balanced detector with high sensitivity and low noise is presented in this paper. The two-stage amplification structure is used to increase electronic gain while keeping an effective bandwidth of about 70 MHz. In order to further…
We present an evaluation of a novel on-chip charge detector, called the Single electron Sensitive Read Out (SiSeRO), for charge-coupled device (CCD) image sensor applications. It uses a p-MOSFET transistor at the output stage with a…
The sensitivity of next-generation gravitational-wave detectors such as Advanced LIGO and LCGT should be limited mostly by quantum noise with an expected technical progress to reduce seismic noise and thermal noise. Those detectors will…
Fault-tolerant spin-based quantum computers will require fast and accurate qubit readout. This can be achieved using radio-frequency reflectometry given sufficient sensitivity to the change in quantum capacitance associated with the qubit…
A novel topology for a high gain two-stage amplifier is proposed. The proposed circuit is designed in a way that the non-dominant pole is at output of the first stage. A positive capacitive feedback (PCF) around the second stage introduces…
The SPLENDOR Collaboration studies novel narrow-gap semiconductors and engineered a substrate agnostic detector platform to achieve $\mathcal{O}$(meV) energy sensitivity designed for low mass dark matter searches. This was achieved using…
This paper discusses a detailed design approach to determine the optimal input impedance (Rin) and bandwidth (BW) for current preamplifiers in Front End Electronics (FEE) of high-accuracy time measurement systems used in particle detection.…
The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency Instrument are broadband receivers (20% relative bandwidth) working at room temperature. The signals coming from the Front End Module are amplified, band pass filtered…
Gotthard-II is a silicon microstrip detector developed for the European X-ray Free-Electron Laser (XFEL.EU). Its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot…
To search for dark matter candidates with masses below $\mathcal{O}$(MeV), the SPLENDOR (Search for Particles of Light dark mattEr with Narrow-gap semiconDuctORs) experiment is developing novel narrow-bandgap semiconductors with electronic…
Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted…
An amplifier has been designed for optimal use of position sensitive thermal neutron detectors using the principle of resistive charge division. The important points in this optimization are: high counting rates and good spatial resolution.…
A field-effect transistor (FET) amplifier for small voltage signals is presented. Its design is elementary and the construction can be afforded by anyone. Despite its simplicity, with a voltage noise less than 1 nV/sqrt(Hz), it outperforms…
A photodiode with 0.55$\pm$0.1 A/W responsivity at a wavelength of 1176.9 nm has been fabricated in a 45 nm microelectronics silicon-on-insulator foundry process. The resonant waveguide photodetector exploits carrier generation in…
We report on the realization of a high sensitivity RF noise measurement scheme to study small current fluctuations of mesoscopic systems at milliKelvin temperatures. The setup relies on the combination of an interferometric ampli- fication…
We present a spectroscopic system constituted by a Silicon Drift Detector (SDD) coupled to a CMOS charge sensitive preamplifier, named SIRIO, specifically designed to reach ultimate low noise levels. The SDD, with an active area of 13 mm ,…
A wide swing charge sensitive amplifier (CSA) has been developed, as a part of a front-end electronics (FEE) readout ASIC, for a prototype silicon tungsten (Si-W) based electromagnetic (EM) calorimeter. The CSA, designed in 0.35 $\mu$m…