English
Related papers

Related papers: TOF-PET detector concept based on organic scintill…

200 papers

Large volume Liquid Argon Time Projection Chambers (LAr-TPC) are used and proposed for neutrino physics and rare event search. Most of these detectors make use of the scintillation light of liquid argon for trigger purposes. Two different…

Instrumentation and Detectors · Physics 2020-04-13 O. Barnabà , A. Menegolli , R. Nardò , M. Pirola , M. C. Prata , G. L. Raselli , E. Romano , M. Rossella

A new type of neutron detector, named Stack Structure Solid organic Scintillator (S$^4$), consisting of multi-layer plastic scintillators with capability to suppress low-energy $\gamma$ rays under high-counting rate has been constructed and…

Beyond conventional organic thin-film transistors, this thesis explores possible paths for the fourth wave of organic electronics. In this context, mixed ionic-electronic conductors and organic electro-chemical transistors (OECTs) are…

Emerging Technologies · Computer Science 2021-11-19 Hans Kleemann

Detailed characterization of the newly available plastic scintillator (EJ-299-33A) having the pulse shape discrimination (PSD) property has been carried out in case of a large-sized detector (5 in.$\times$5 in.). The pulse height response…

Instrumentation and Detectors · Physics 2020-12-08 Pratap Roy , K. Banerjee , A. K. Saha , C. Bhattacharya , J. K. Meenaa , P. Bhaskar , S. Mukhopadhyay , S. Bhattacharya

In recent years important progress in micropattern gaseous detectors has been achieved in the use of resistive material to build compact spark-protected devices. The novel idea presented here consists of the polarisation of WELL structures…

Instrumentation and Detectors · Physics 2015-03-19 Rui De Oliveira , Marcello Maggi , Archana Sharma

Transmission optical coherence tomography (OCT) enables analysis of biological specimens in vitro through detection of forward scattered light. Up to now, transmission OCT was considered as a technique that cannot directly retrieve…

Optics · Physics 2024-05-24 Wojciech Krauze , Martyna Mazur , Arkadiusz Kuś

Neutron detectors are extensively used at many nuclear research facilities across Europe. Their application range covers many topics in basic and applied nuclear research: in nuclear structure and reaction dynamics (reaction reconstruction…

Instrumentation and Detectors · Physics 2017-11-22 M. Degerlier , S. Carturan , F. Gramegna , T. Marchi , M. Dalla Palma , M. Cinausero , G. Maggioni , A. Quaranta , G. Collazuol , J. Bermudez

Large-scale particle physics detectors often contain millions of repeated components, making precise and efficient quality control essential. We have developed a semiautomatic system for dimensional screening of 1 cm$^3$ plastic…

Instrumentation and Detectors · Physics 2026-03-31 Tatsuya Kikawa , Mao Tani , Atsuko K. Ichikawa , Tsunayuki Matsubara , Tsuyoshi Nakaya , Tomohisa Ogawa

Two detection systems based on optical readout were developed: a. Integrative optical detector A 2nd generation of Time-Resolved Integrative Optical Neutron (TRION) detector was developed. It is based on an integrative optical technique,…

Instrumentation and Detectors · Physics 2017-05-01 Ilan Mor

Optical coherence tomography (OCT) is a powerful biomedical imaging technology that relies on the coherent detection of backscattered light to image tissue morphology in vivo. As a consequence, OCT is susceptible to coherent noise (speckle…

The demands on detectors for particle detection as well as for medical and astronomical X-ray imaging are continuously pushing the development of novel pixel detectors. The state of the art in pixel detector technology to date are hybrid…

Instrumentation and Detectors · Physics 2009-11-11 Hans Krueger

Plastic-scintillator detectors are devices used for the detection of elementary particles. They provide good particle identification with excellent time resolution, whilst being inexpensive due to the affordability of plastic materials.…

The TT-PET collaboration is developing a small animal TOF-PET scanner based on silicon detectors featuring 30 ps RMS time resolution and intended to be inserted in an existing MRI scanner. The TT-PET scanner makes use of a stack of layers…

Organic glass scintillators are an interesting alternative to liquid scintillators, offering many advantageous characteristics with few drawbacks. In this paper we investigate the influence of light self-absorption in the organic glass…

A detector material or configuration that can provide an unambiguous indication of neutron capture can substantially reduce random coincidence backgrounds in antineutrino detection and capture-gated neutron spectrometry applications. Here…

Instrumentation and Detectors · Physics 2015-05-28 P. Nelson , N. S. Bowden

A time-of-flight system with a plastic scintillator coupled to photomultipliers is developed for the external target facility (ETF). This system can satisfy the requirement of an ultrahigh vacuum ($\sim 10^{-9}$ mbar), a high counting rate…

Instrumentation and Detectors · Physics 2013-05-23 Zhang Xueheng , Yu Yuhong , Sun Zhiyu , Mao Ruishi , Wang Shitao , Zhou Yong , Yan Duo , Liu Longxiang

Liquid xenon time projection chambers offer a homogeneous detection medium with excellent intrinsic energy resolution, fast scintillation, and true three-dimensional position sensitivity, making them an attractive alternative to…

Instrumentation and Detectors · Physics 2026-03-30 B. Li , Y. Ma , K. Ni

Large spherical scintillation detectors are playing an increasingly important role in experimental neutrino physics studies. From the instrumental point of view the primary signal response of these set-ups is constituted by the time and…

Instrumentation and Detectors · Physics 2008-11-26 Paolo Lombardi , Gioacchino Ranucci

Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall…

PET is an established medical diagnostic imaging method. Continuous improvements are aimed at refining image reconstruction, reducing the amount of radioactive tracer and combining with targeted therapy. TOF-PET provides the localization of…

Medical Physics · Physics 2021-11-17 Tomasz Matulewicz