English
Related papers

Related papers: TOF-PET detector concept based on organic scintill…

200 papers

This master thesis presents a new type of Positron Emission TOF Apparatus using Liquid xenOn (PETALO). The detector is based in the Liquid Xenon Scintillating Cell (LXSC). The cell is a box filled with liquid xenon (LXe) whose transverse…

Medical Physics · Physics 2016-06-01 J. M. Benlloch-Rodriguez

Time-of-Flight Positron Emission Tomography is a medical imaging technique, based on the detection of two back-to-back {\gamma}-photons generated from radiotracers injected in the body. Its limit is the ability of employed scintillation…

We present the original computer code for the simulation of multi-element detection system of the compact positron-emission tomograph based on a scintillator-photodiode type of detection elements. The use of such type of detection elements…

Medical Physics · Physics 2017-05-08 Alex Fomin

Prostate cancer is the most common disease in men and the second leading cause of death from cancer. Generic large imaging instruments used in cancer diagnosis have sensitivity, spatial resolution, and contrast inadequate for the task of…

The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited…

Most of the time-of-flight systems as well as the fast interaction trigger detectors have large surfaces and the principal requirements for the above mentioned detectors is a good time resolution of the order 100-200ps. The easiest solution…

Instrumentation and Detectors · Physics 2024-01-18 Varlen Grabski

PET is a functional imaging method that visualizes metabolic processes. TOF information can be derived from coincident detector signals and incorporated into image reconstruction to enhance the SNR. PET detectors are typically assessed by…

Instrumentation and Detectors · Physics 2025-04-24 Stephan Naunheim , Luis Lopes de Paiva , Vanessa Nadig , Yannick Kuhl , Stefan Gundacker , Florian Mueller , Volkmar Schulz

Intraoperative Gamma Probe (IPG) remains the current gold standard modality for sentinel lymph node identification and tumor removal in cancer patients. However, even alongside the optical dyes they do not meet with <5% false negative rates…

Medical Physics · Physics 2022-01-26 S. Sajedi , L. Blackberg , S. Majewski , H. Sabet

The recent development of water-based liquid scintillator and the concurrent development of high-efficiency and high-precision-timing light sensors has opened up the possibility for a new kind of large-scale detector capable of a very broad…

Instrumentation and Detectors · Physics 2019-08-14 Gabriel D. Orebi Gann

The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter…

This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed Positron Emission Tomography which utilizes plastic…

A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly…

Novel TOF-PET scanner solutions demand, apart from the state of the art detectors, software for fast processing of the gathered data, monitoring of the whole scanner and reconstruction of the PET image. In this article we present an…

Positron emission tomography (PET) is the most sensitive biomedical imaging modality for non-invasively detecting and visualizing positron-emitting radiopharmaceuticals within a subject. In PET, measuring the time-of-flight (TOF)…

Instrumentation and Detectors · Physics 2024-10-17 Minseok Yi , Daehee Lee , Alberto Gola , Stefano Merzi , Michele Penna , Jae Sung Lee , Simon R. Cherry , Sun Il Kwon

The main task of the Target Tracker detector of the long baseline neutrino oscillation OPERA experiment is to locate in which of the target elementary constituents, the lead/emulsion bricks, the neutrino interactions have occurred and also…

Instrumentation and Detectors · Physics 2008-11-26 T. Adam

The new CDFII detector incorporates a Time-of-Flight detector (TOF), employing plastic scintillator bars and fine-mesh photomultipliers. Since August 2001 the TOF system has been fully instrumented and integrated into the CDFII data…

The project OptoTracker aims to investigate a new approach to track charged particles in a scintillating material, by using the optical signal. Our idea is to reconstruct the trajectory of a charged particle by collecting the scintillation…

Instrumentation and Detectors · Physics 2016-06-10 A. Celentano

The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which…

We present several novel ionization-electron and scintillation-photon recording concepts in noble-liquid detectors, for future applications in particle and astroparticle physics and in other fields. These involve both single- and dual-phase…

Instrumentation and Detectors · Physics 2022-08-17 Amos Breskin

A radio-guided surgery technique exploiting $\beta^-$ emitters is under development. It aims at a higher target-to-background activity ratio implying both a smaller radiopharmaceutical activity and the possibility of extending the technique…