Related papers: A waveguide-coupled thermally-isolated radiometric…
A differential, membrane-based nanocalorimeter for general specific heat studies of very small samples, ranging from 0.5 mg to sub-{\mu}g in mass, is described. The calorimeter operates over the temperature range from above room temperature…
We study a three-terminal setup consisting of a single-level quantum dot capacitively coupled to a quantum point contact. The point contact connects to a source and drain reservoirs while the quantum dot is coupled to a single base…
We present a novel system to calibrate millimeter-wave polarimeters for CMB polarization measurements. This technique is an extension of the conventional metal mirror rotation approach, however it employs cryogenically-cooled blackbody…
A novel microfabricated, all-electrical measurement platform is presented for a direct, accurate and rapid determination of the thermal conductivity and diffusivity of liquid and solid materials. The measurement approach is based on the…
Cost-efficient and easily integrable broadband mid-infrared (mid-IR) sources would significantly enhance the application space of photonic integrated circuits (PICs). Thermal incandescent sources are superior to other common mid-IR emitters…
We present an efficient fabrication method for absorptive microwave filters based on Eccosorb CR-124. Filters are fabricated from readily available parts and their cut-off frequency can be set by their length. They exhibit desirable…
In this work, magnetization dynamics is studied at low temperatures in a hybrid system that consists of thin epitaxial magnetic film coupled with superconducting planar microwave waveguide. The resonance spectrum was observed in a wide…
Low thermal conductivity is favorable for preserving the temperature gradient between the two ends of a thermoelectric material in order to ensure continuous electron current generation. In high-performance thermoelectric materials, there…
Optomechanical magnetometers enable highly sensitive magnetic field sensing. However, all such magnetometers to date have been optically excited and read-out either via free space or a tapered optical fiber. This limits their scalability…
Magnetic dc susceptibility between 1.5 and 800 K, ac susceptibility and magnetization, thermodynamic properties, temperature dependence of radio and audio-wave dielectric constants and conductivity, contact-free dielectric constants at…
Temperature-dependent reflectivity measurements on the kagome metal CsV$_3$Sb$_5$ in a broad frequency range of $50-20000$ cm$^{-1}$ down to $T$=10 K are reported. The charge-density wave (CDW) formed below $T_{\rm CDW}$ = 94 K manifests…
This paper introduces a Bayesian inference framework for two-dimensional steady-state heat conduction, focusing on the estimation of unknown distributed heat sources in a thermally-conducting medium with uniform conductivity. The goal is to…
On-chip photodetectors are essential components in optical communications as they convert light into an electrical signal. Photobolometers are type of photodetector that functions through a resistance change caused by electronic temperature…
We present an exhaustive theoretical analysis of charge and thermoelectric transport in a normal metal-ferromagnetic insulator-superconductor (NFIS) junction, and explore the possibility of its use as a sensitive thermometer. We…
We describe the optical characterisation of two silicon cold-electron bolometers each consisting of a small ($32 \times 14~\mathrm{\mu m}$) island of degenerately doped silicon with superconducting aluminium contacts. Radiation is coupled…
We present a compact current sensor based on a superconducting microwave lumped-element resonator with a nanowire kinetic inductor, operating at 4.2 K. The sensor is suitable for multiplexed readout in GHz range of large-format arrays of…
The thermoelectric power S and the thermal conductivity k of stoichiometric and vacancy-doped CaB6 have been measured between 5 and 300 K. The thermopower of both materials is surprisingly large at room temperature. Across the whole covered…
A compact cryogenic calibration target is presented that has a peak diffuse reflectance, $R \le 0.003$, from $800-4,800\,{\rm cm}^{-1}$ $(12-2\,\mu$m). Upon expanding the spectral range under consideration to $400-10,000\,{\rm cm}^{-1}$…
We describe a compact calorimeter that opens ultra-low temperature heat capacity studies of small metal crystals in moderate magnetic fields. The performance is demonstrated on the canonical heavy Fermion metal YbRh2Si2. Thermometry is…
We present the design of a continuous-wave, highly sensitive optical spectrometer for millimeter-wave frequencies between 50 and 1000 GHz. The spectrometer uses photomixing of near-infrared light to generate radiation in a wide frequency…