English
Related papers

Related papers: Multigap RPC for PET: development and optimisation…

200 papers

A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this…

Instrumentation and Detectors · Physics 2022-12-21 Atsushi Oya , Kei Ieki , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Kensuke Yamamoto

We propose an alternative approach for the detection of fast neutrons in the energy range from 10-4 to 5 MeV based on 10B-RPCs (hybrid double-gap Resistive Plate Chambers with 10B4C neutron converters) surrounded by a polyethylene…

Instrumentation and Detectors · Physics 2022-02-23 A. Morozov , L. M. S. Margato , A. Blanco , D. Galaviz

The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the…

A Monte Carlo simulation-based optimization of a multilayer 10B-RPC thermal neutron detector is performed targeting an increase in the counting rate capability while maintaining high (>50%) detection efficiency for thermal neutrons. The…

Instrumentation and Detectors · Physics 2020-04-22 A. Morozov , L. M. S. Margato , I. Stefanescu

A sampling calorimeter equipped with gaseous sensor layers with digital readout is near perfect for "Particle Flow Algorithm" approach, since it is homogeneous over large surfaces, robust, cost efficient, easily segmentable to any readout…

Instrumentation and Detectors · Physics 2015-06-19 Y. Haddad , M. Ruan , V. Boudry

Muon radiography often referred to as muography, is an imaging technique that uses freely available cosmic-ray muons to study the interior structure of natural or man-made large-scale objects. The amount of multidisciplinary applications of…

Keeping in mind the requirements of high rate capable, cost effective, large area detectors to be used in future high energy physics experiments, commercially available bakelite plates having moderate bulk resistivity are used to build an…

Instrumentation and Detectors · Physics 2024-01-25 Arindam Sen , Sayak Chatterjee , Shreya Roy , Saikat Biswas , Supriya Das

The performance of hybrid GaAs pixel detectors as X-ray imaging sensors were investigated at room temperature. These hybrids consist of 300 mu-m thick GaAs pixel detectors, flip-chip bonded to a CMOS Single Photon Counting Chip (PCC). This…

The gas detector glass resistivity parallel chamber (GRPC) is proposed to use in the Hadron calorimeter (HCAL), the read-out system is based on the semi-digital system, then the charge information from GRPC is needed. To better understand…

Instrumentation and Detectors · Physics 2013-06-11 Han Ran

Particle IDentification (PID) is a central requirement of the experiments at the future EIC. Hadron PID at high momenta by RICH techniques requires the use of low density gaseous radiators, where the challenge is the limited length of the…

We report on the development of an GRPCs (Glass Resistive Plate chambers) Semi- Digital hadron calorimeter for the future International Linear Collider (ILC).Two types of GRPCs (small and 1m2) were tested in PS beam at CERN. Detector…

Instrumentation and Detectors · Physics 2010-08-24 Khaled Belkadhi

Gas Electron Multiplier (GEM) is a cutting edge Micro Pattern Gaseous detector (MPGD) technology suitable as tracking device in high rate Heavy-Ion (HI) experiments for their good spatial resolution and most importantly high rate handling…

High Energy Physics - Experiment · Physics 2025-05-07 S. Mandal , S. Gope , S. Das , S. Biswas

The reduction of the average charge per count in the gas along with the capability to discriminate very small signals from noise can allow an efficient and long-term Resistive Plate Chamber detector operation in high radiation background…

Instrumentation and Detectors · Physics 2020-12-30 Luca Pizzimento

We present the original computer code for the simulation of multi-element detection system of the compact positron-emission tomograph based on a scintillator-photodiode type of detection elements. The use of such type of detection elements…

Medical Physics · Physics 2017-05-08 Alex Fomin

A hybrid readout Time Projection Chamber (TPC) has a simultaneous optical- and charge readout. The optical readout provides 2D images of particle tracks in the active volume, whilst the charge readout provides additional information on the…

Instrumentation and Detectors · Physics 2022-12-21 Alexander Deisting

The upgrade of the Resistive Plate Chamber (RPC) detector, in order to increase the detector rate capability and to be able to work efficiently in high rate environment, consists in the reduction of the operating voltage along with the…

Time-Of-Flight (TOF) is a noble technique that is used in Positron Emission Tomography (PET) imaging worldwide. The scintillator based imaging system that is being used around the world for TOF-PET is very expensive. Multi-gap Resistive…

Instrumentation and Detectors · Physics 2018-07-02 Rajesh Ganai , Shaifali Mehta , Mehulkumar Shiroya , Mitali Mondal , Zubayer Ahammed , Subhasis Chattopadhyay

A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{\mu m}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use…

Instrumentation and Detectors · Physics 2024-01-25 Kei Ieki , Weiyuan Li , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Atsushi Oya , Masato Takahashi , Kensuke Yamamoto