English
Related papers

Related papers: The Reconstruction Algorithm Study of 2D Interpola…

200 papers

The two high-angle Time Projection Chambers of the T2K experiment are equipped with a new readout system based on resistive Micromegas detector technology, and utilize custom-made electronics based on AFTER chips for signal processing. This…

In this work, a serial on-line cluster reconstruction technique based on FPGA technology was developed to compress experiment data and reduce the dead time of data transmission and storage. At the same time, X-ray imaging experiment based…

Instrumentation and Detectors · Physics 2017-03-28 Hui-Yin Wu , He-Run Yang , Wei Zhang , Jian-Jin Zhou , Sheng-Ying Zhao , Chen-Gui Lu , Jun-Wei Zhang , Bi-Tao Hu , Yi Zhang , Wen-Quan Cao

This contribution investigates a prototype of a TPC readout with a highly pixelated CMOS ASIC, which is an option for charged particles tracking of the ILC. A triple GEM stack was joined with a TimePix and MediPix2 chip (pixel size of…

Instrumentation and Detectors · Physics 2009-02-16 A. Bamberger , K. Desch , U. Renz , M. Titov , N. Vlasov , P. Wienemann , S. Zimmermann , A. Zwerger

The TOTEM experiment at LHC has chosen the triple Gas Electron Multiplier (GEM) technology for its T2 telescope which will provide charged track reconstruction in the rapidity range 5.3<|eta|<6.5 and a fully inclusive trigger for…

Instrumentation and Detectors · Physics 2009-09-29 S. Lami , G. Latino , E. Oliveri , L. Ropelewski , N. Turini

The triple GEM detector is a micropattern gas detector which consists of a primary ionisation gap and three consecutive gas electron multiplier (GEM) foils. A printed circuit board with readout strips detects the current induced by the…

High Energy Physics - Experiment · Physics 2009-10-31 M. Ziegler , P. Sievers , U. Straumann

This paper presents the experimental demonstration of a dual-input/dual-output reflective impedance metasurface. The design of the metasurface relies on the Method of Moments and leverages auxiliary surface waves to achieve anomalous…

Applied Physics · Physics 2023-10-25 Jean Louis Keyrouz , Vasileios G. Ataloglou , George V. Eleftheriades

A novel approach is presented to unfold particle hit positions in tracking detectors with multiplexed readout representing an underdetermined system of linear equations. The method does not use any prior information about the hit positions,…

Instrumentation and Detectors · Physics 2019-09-24 B. Radics , G. Janka , D. A. Cooke , S. Procureur , P. Crivelli

The requirement of a large number of electronic channels poses a big challenge for Micro-pattern Gas Detector (MPGD) to achieve good spatial resolution. By using the redundancy that at least two neighboring strips record the signal of a…

Instrumentation and Detectors · Physics 2016-08-03 Bin-Xiang Qi , Shu-Bin Liu , Heng Ji , Zhong-Tao Shen , Si-Yuan Ma , Hong-Bang Liu , Wen-Qian Huang , Qi An

For the International Large Detector (ILD) at the planned International Linear Collider (ILC) a Time Projection Chamber (TPC) is foreseen as the main tracking detector. To achieve the required point resolution, Micro-Pattern Gaseous…

Instrumentation and Detectors · Physics 2020-06-26 Ties Behnke , Ralf Diener , Ulrich Einhaus , Uwe Krämer , Paul Malek , Oliver Schäfer , Mengqing Wu

The time resolution of a double-stage Thick-GEM (THGEM) detector was measured with UV-photons and relativistic electrons. The photon detector, with semitransparent- or reflective-photocathode yielded time resolution of about 8-10ns RMS for…

Instrumentation and Detectors · Physics 2008-12-18 Raz Alon , Marco Cortesi , Amos Breskin , Rachel Chechik

An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas…

A new Time Projection Chamber (TPC) is currently under development for the sPHENIX experiment at RHIC. The TPC will be read out using multistage GEM detectors on each end and will be divided into approximately 40 pad layers in radius. Each…

Instrumentation and Detectors · Physics 2018-08-15 B. Azmoun , P. Garg , T. K. Hemmick , M. Hohlmann , A. Kiselev , M. L. Purschke , C. Woody , A. Zhang

We present a new algorithm, called Multiresolution Regularized Expectation Maximization (MREM), for the reconstruction of gamma-ray intensity maps from COMPTEL data. The algorithm is based on the iterative Richardson-Lucy scheme to which we…

Performance of triple GEM prototypes has been evaluated by means of a muon beam at the H4 line of the SPS test area at CERN. The data from two planar prototypes have been reconstructed and analyzed offline with two clusterization methods:…

This paper presents an investigation of the use of interest point detection algorithms from image processing applied to reconstruction of interactions in high granularity tracking detectors. Their purpose is to extract keypoints from the…

Instrumentation and Detectors · Physics 2014-11-21 Ben Morgan

We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron…

Instrumentation and Detectors · Physics 2022-03-09 M. Abbas , M. Abbrescia , H. Abdalla , A. Abdelalim , S. AbuZeid , A. Agapitos , A. Ahmad , A. Ahmed , W. Ahmed , C. Aimè , C. Aruta , I. Asghar , P. Aspell , C. Avila , J. Babbar , Y. Ban , R. Band , S. Bansal , L. Benussi , V. Bhatnagar , M. Bianco , S. Bianco , K. Black , L. Borgonovi , O. Bouhali , A. Braghieri , S. Braibant , S. Butalla , S. Calzaferri , M. Caponero , F. Cassese , N. Cavallo , S. Chauhan , A. Colaleo , J. Collins , A. Conde Garcia , M. Dalchenko , A. De Iorio , G. De Lentdecker , D. Dell Olio , G. De Robertis , W. Dharmaratna , S. Dildick , B. Dorney , R. Erbacher , F. Fabozzi , F. Fallavollita , A. Ferraro , D. Fiorina , E. Fontanesi , M. Franco , C. Galloni , P. Giacomelli , S. Gigli , J. Gilmore , M. Gola , M. Gruchala , A. Gutierrez , R. Hadjiiska , T. Hakkarainen , J. Hauser , K. Hoepfner , M. Hohlmann , H. Hoorani , T. Huang , P. Iaydjiev , A. Irshad , A. Iorio , F. Ivone , J. Jaramillo , D. Jeong , V. Jha , A. Juodagalvis , E. Juska , B. Kailasapathy , T. Kamon , P. Karchin , A. Kaur , H. Kaur , H. Keller , H. Kim , J. Kim , A. Kumar , S. Kumar , H. Kumawat , N. Lacalamita , J. S. H. Lee , A. Levin , Q. Li , F. Licciulli , L. Lista , K. Liyanage , F. Loddo , M. Lohan , M. Luhach , M. Maggi , Y. Maghrbi , N. Majumdar , K. Malagalage , S. Malhotra , S. Martiradonna , N. Mccoll , C. McLean , J. Merlin , M. Misheva , D. Mishra , G. Mocellin , L. Moureaux , A. Muhammad , S. Muhammad , S. Mukhopadhyay , M. Naimuddin , P. Netrakanti , S. Nuzzo , R. Oliveira , L. Pant , P. Paolucci , I. C. Park , L. Passamonti , G. Passeggio , A. Peck , N. Perera , L. Petre , H. Petrow , D. Piccolo , D. Pierluigi , G. Raffone , M. Rahmani , F. Ramirez , A. Ranieri , G. Rashevski , M. Ressegotti , C. Riccardi , M. Rodozov , E. Romano , C. Roskas , B. Rossi , P. Rout , D. Roy , J. D. Ruiz , A. Russo , A. Safonov , D. Saltzberg , G. Saviano , A. Shah , A. Sharma , R. Sharma , M. Shopova , F. Simone , J. Singh , E. Soldani , U. Sonnadara , E. Starling , B. Stone , J. Sturdy , G. Sultanov , Z. Szillasi , D. Teague , D. Teyssier , T. Tuuva , M. Tytgat , I. Vai N. Vanegas , R. Venditti , P. Verwilligen , W. Vetens , A. Virdi , P. Vitulo , A. Wajid , D. Wang , K. Wang , I. J. Watson , J. Weatherwax , N. Wickramage , D. D. C. Wickramarathna , Y. Yang , U. Yang , J. Yongho , I. Yoon , Z. You , I. Yu , S. Zaleski

A study has been carried out to evaluate the performance stability of Gas Electron Multiplier (GEM) chamber prototypes in the laboratory using $^{55}$Fe radiation source with Argon and CO$_2$ gas mixture. This research focuses on the…

Instrumentation and Detectors · Physics 2026-04-10 S. Mandal , S. Gope , S. Das , S. Biswas

A template fitting technique for reconstructing the amplitude of signals produced by the lead tungstate crystals of the CMS electromagnetic calorimeter is described. This novel approach is designed to suppress the increased out-of-time…

Instrumentation and Detectors · Physics 2020-10-05 CMS Collaboration

We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and photocathode at the CERN SPS H4 beam line. This work provides…

A new readout technique was developed with the primary aim of keeping the number of channels in the front-end electronics as low as possible when scaling up the sensitive area of a Resistive Plate Chamber (RPC). The readout method here…

Instrumentation and Detectors · Physics 2024-07-16 João Pedro de Carvalho Saraiva , Alberto Blanco Castro