English
Related papers

Related papers: A new mass value for 7Li

200 papers

Accurate atomic mass measurements of neutron-deficient and neutron-rich nuclides around the doubly-magic 208Pb and of neutron-rich cesium isotopes were performed with the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. The masses of…

Nuclear Experiment · Physics 2008-11-26 C. Weber , G. Audi , D. Beck , K. Blaum , G. Bollen , F. Herfurth , A. Kellerbauer , H. -J. Kluge , D. Lunney , S. Schwarz

Light-Ion Trap (LIONTRAP), a high-precision Penning-trap mass spectrometer, was used to determine the atomic mass of $^{4}$He. Here, we report a 12 parts-per-trillion measurement of the mass of a $^{4}$He$^{2+}$ ion, $m(^{4}\text{He}^{2+}$)…

We report on the precise measurement of the atomic mass of a single proton with a purpose-built Penning-trap system. With a precision of 32 parts-per-trillion our result not only improves on the current CODATA literature value by a factor…

The precise knowledge of the atomic masses of light atomic nuclei, e.g. the proton, deuteron, triton and helion, is of great importance for several fundamental tests in physics. However, the latest high-precision measurements of these…

In this letter, we report a new mass for $^{11}$Li using the trapping experiment TITAN at TRIUMF's ISAC facility. This is by far the shortest-lived nuclide, $t_{1/2} = 8.8 \rm{ms}$, for which a mass measurement has ever been performed with…

The Penning trap mass spectrometer JYFLTRAP was used to measure the atomic masses of radioactive nuclei with an uncertainty better than 10 keV. The atomic masses of the neutron-deficient nuclei around the N = Z line were measured to improve…

The masses of the lightest atomic nuclei and the electron mass are interlinked and are crucial in a wide range of research fields, with their values affecting observables in atomic, molecular and neutrino physics as well as metrology. The…

The atomic mass difference of 163Ho and 163Dy has been directly measured with the Penning trap mass spectrometer SHIPTRAP applying the novel phase imaging ion cyclotron resonance technique. Our measurement has solved the long standing…

The atomic mass of uranium-238 has been determined to be $238.050\,787\,618(15)\,\text{u}$, improving the literature uncertainty by two orders of magnitude. It is obtained from a measurement of the mass ratio of $^{238}$U$^{47+}$ and…

We report on the precise mass measurement of the $^{173}$Hf isotope performed at the Ion Guide Isotope Separator On-Line facility using the JYFLTRAP double Penning trap mass spectrometer. The new mass-excess value, ${\mathrm{ME} =…

Accepted values of the masses of several subatomic particles have been under debate since recent measurements in Penning traps produced more precise yet incompatible results, implying possible inconsistencies in closely related physical…

High-precision mass measurements of $^{63}$Cu, $^{64-66}$Zn, $^{65}$Ga, $^{65-67}$Ge, $^{67}$As, $^{78,81}$Br, $^{80}$Rb, and $^{79}$Sr were performed utilizing a multireflection time-of-flight mass spectrograph combined with the gas-filled…

The absolute atomic mass of $^{208}$Pb has been determined with a fractional uncertainty of $7\times 10^{-11}$ by measuring the cyclotron-frequency ratio $R$ of $^{208}$Pb$^{41+}$ to $^{132}$Xe$^{26+}$ with the high-precision Penning-trap…

The masses of the ground and isomeric states in $^{124,125}$Ag have been measured using the phase-imaging ion-cyclotron-resonance technique at the JYFLTRAP double Penning trap mass spectrometer. The ground states of $^{124}$Ag and…

For the first time a direct determination of the atomic mass difference of 187Re and 187Os has been performed with the Penning-trap mass spectrometer SHIPTRAP applying the novel phase-imaging ion-cyclotron-resonance technique. The obtained…

Nuclear charge radii of $^{7,9,10,11}$Be have been determined by high-precision laser spectroscopy. On-line measurements were performed with collinear laser spectroscopy in the $2s_{1/2} \to 2p_{1/2}$ transition on a beam of Be$^{+}$ ions.…

Angular distributions of the 7Li(6Li,6Li)7Li elastic scattering and the 7Li(6Li,7Li_{g.s.})6Li, 7Li(6Li,7Li*_{0.48})6Li transfer reactions at Ec.m. = 23.7 MeV were measured with the Q3D magnetic spectrograph. The optical potential of…

The JYFLTRAP mass spectrometer was used to measure the masses of neutron-rich nuclei in the region between N = 28 to N = 82 with uncertainties better than 10 keV. The impacts on nuclear structure and the r-process paths are reviewed.

The electron mass in atomic mass units has been determined with a relative uncertainty of $2.8\cdot 10^{-11}$, which represents a 13-fold improvement of the 2010 CODATA value. The underlying measurement principle combines a high-precision…

Atomic Physics · Physics 2016-04-18 Florian Köhler , Sven Sturm , Anke Kracke , Günter Werth , Wolfgang Quint , Klaus Blaum

The Penning trap mass spectrometer JYFLTRAP, coupled to the Ion-Guide Isotope Separator On-Line (IGISOL) facility at Jyvaskyla, was employed to measure the atomic masses of neutron rich 85 to 92Br and 94 to 97Rb isotopes with a typical…

‹ Prev 1 2 3 10 Next ›