Related papers: A vector control and data acquisition system for t…
The current generation of precision radial velocity (RV) spectrographs are seeing-limited instruments. In order to achieve high spectral resolution on 8m class telescopes, these spectrographs require large optics and in turn, large…
For the PIP-II Injector Test (PI-Test) at Fermilab, a four-vane radio frequency quadrupole (RFQ) is designed to accelerate a 30-keV, 1-mA to 10-mA, H- beam to 2.1 MeV under both pulsed and continuous wave (CW) RF operation. The available…
Powered operation of Cryomodule 1 (CM-1) at the Fermilab SRF Beam Test Facility began in late 2010. Since then a series of tests first on the eight individual cavities and then the full cryomodule have been performed. We report on the…
The ISIS synchrotron at the Rutherford Appleton Laboratory in the UK now routinely uses a dual harmonic RF system to accelerate beam currents in excess of 230uA to run two target stations simultaneously. The acceleration in the ISIS…
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis…
The Fermilab Accelerator Science and Technology (FAST) Facility at FNAL is a dedicated research and development center focused on advancing particle accelerator technologies for future applications worldwide. Currently, a key objective of…
A semi-empirical method that allows us to predict intensity of generated field emission in superconducting RF cavities is described. Spatial, angular and energy distributions of the generated radiation are calculated with the FISHPACT code.…
Superconducting Radio-Frequency (SRF) cavities operating in continuous wave (CW) mode and with low beam loading are devices characterized by a high loaded quality factor, in the order of 10^7, and narrow bandwidth, in the order of 10 Hz.…
The latest generation of IPMs installed in the Fermilab Main Injector and Recycler incorporate a 1 kG permanent magnet, a newly designed high-gain, rad-tolerant preamp, and a control grid to moderate the charge that is allowed to arrive on…
Superconducting linacs are capable of producing intense, stable, high-quality electron beams that have found widespread applications in science and industry. The 9-cell 1.3-GHz superconducting standing-wave accelerating RF cavity originally…
The Horizontal Test Stand (HTS) SRF Cavity and Cryomodule 1 (CM1) of eight 9-cell, 1.3GHz SRF cavities are operating at Fermilab. For the cryogenic control system, how to hold liquid level constant in the cryostat by regulation of its…
Fermilab operates several clusters for lattice gauge computing. Minimal manpower is available to manage these clusters. We have written a number of tools and developed techniques to cope with this task. We describe our tools which use the…
Accelerator magnet test facilities frequently need to measure different magnets on differently equipped test stands and with different instrumentation. Designing a modular and highly reusable system that combines flexibility built-in at the…
The design and application of learning feedforward controllers (LFFC) for the one-staged refrigeration cycle model described in the PID2018 Benchmark Challenge is presented, and its effectiveness is evaluated. The control system consists of…
In this article it is presented an FPGA based $M$ulti-$V$oltage $T$hreshold (MVT) system which allows of sampling fast signals ($1-2$ ns rising and falling edge) in both voltage and time domain. It is possible to achieve a precision of time…
We report on a traceable calibration system for a 3500mm-long console that carries a measurement system for inspecting the diameter of a circular reactor chassis. The system uses two single-pass laser interferometers with homodyne fringe…
The main role of the ITER Radial Neutron Camera (RNC) diagnostic is to measure in real-time the plasma neutron emissivity profile at high peak count rates for a time duration up to 500 s. Due to the unprecedented high performance conditions…
In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These devices will be…
Providing high data rates is one of the big concerns in visible light communication (VLC) systems. This paper introduces a data centre design that use a VLC system for downlink communication. In this work, RYGB laser diodes (LD) are used as…
A Buncher or Capture Cavity (BCC) Cryomodule is currently in development at Fermilab for use in a second injector for LCLS-II-HE. The BCC Cryomodule is designed to contain one 1.3 GHz cavity and one solenoid magnet as part of a 100MeV low…