English
Related papers

Related papers: A Comparative Numerical Study on GEM, MHSP and MSG…

200 papers

We present megas, a new software tool that improves the simulation of the Micromegas gas detectors. Our tool offers the possibility to configure multiple arrangements with one or more layers of MM detectors. A series of simple commands can…

Instrumentation and Detectors · Physics 2020-08-28 Dan A. Ciubotaru , Michele Renda

We briefly review the concept and properties of the Thick GEM (THGEM); it is a robust, high-gain gaseous electron multiplier, manufactured economically by standard printed-circuit drilling and etching technology. Its operation and structure…

Instrumentation and Detectors · Physics 2008-12-18 A. Breskin , R. Alon , M. Cortesi , R. Chechik , J. Miyamoto , V. Dangendorf , J. Maia , J. M. F. Dos Santos

The Gas Electron Multiplier (GEM) foil is an amplification stage that has been introduced to overcome the problem of discharges observed in gaseous detectors. There are two major production techniques of GEM foils: double-mask and…

Instrumentation and Detectors · Physics 2021-12-02 Othmane Bouhali , Kerstin Hoepfner , Francesco Ivone , Teruki Kamon , Henning Keller , Shivali Malhotra , Badriya Al Rashdi

The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same…

Currently a revolution is taking place in the development of gaseous detectors of photons and particles. Parallel plate-type and wire-type detectors which dominated for years in high energy and space flight experiments are now being…

Instrumentation and Detectors · Physics 2017-08-23 T. Francke , V. Peskov

We explore learning pixelwise correspondences between images of deformable objects in different configurations. Traditional correspondence matching approaches such as SIFT, SURF, and ORB can fail to provide sufficient contextual information…

Computer Vision and Pattern Recognition · Computer Science 2020-10-12 Aditya Ganapathi , Priya Sundaresan , Brijen Thananjeyan , Ashwin Balakrishna , Daniel Seita , Ryan Hoque , Joseph E. Gonzalez , Ken Goldberg

A Time Projection Chamber (TPC) using micro-pattern gas detectors is planned as the main tracking device for a detector at the next Linear Collider. A novel support structure for Gas Electron Multipliers (GEMs), which minimizes the material…

Instrumentation and Detectors · Physics 2015-06-17 T. Behnke , F. Müller , A. Münnich , K. Zenker

A prototype Gas Electron Multiplier (GEM) detector is under construction for medical imaging purposes. A single thick GEM of size 10x10 cm^2 is assembled inside a square shaped air-tight box which is made of Perspex glass. In order to…

Instrumentation and Detectors · Physics 2013-07-05 N. N. Mondal , S. Chattopadhyay , M. R. Dutta Mazumdar , A. K. Dubey , Y. P. Vioygi

We have developed and tested several new designs of GEM detectors with micropattern electrodes manufactured by microelectronic technology. In one design, the inner layer of the detector electrode consists of thin metallic strips and the…

Instrumentation and Detectors · Physics 2009-06-25 A. Di Mauro , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

We have developed microstrip gas counters manufactured on standard printed circuit board and having the following features: resistive cathode strips, thin (10 micron) metallic anode strips and electrodes protected against surface discharges…

Instrumentation and Detectors · Physics 2011-07-28 R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between the electrodes are created. The absence of plastic insulation between the electrodes of WGEMs excludes unwanted…

Instrumentation and Detectors · Physics 2020-06-12 B. M. Ovchinnikov , V. V. Parusov

In recent years, micropattern gaseous detectors, which comprise a two-dimensional readout structure within one PCB layer, received significant attention in the development of precision and cost-effective tracking detectors in medium and…

Instrumentation and Detectors · Physics 2015-06-22 Tai-Hua Lin , Andreas Düdder , Matthias Schott , Chrysostomos Valderanis , Laura Wehner , Robert Westenberger

The Inner Tracker System of the HERA-B experiment at DESY consists of 184 Microstrip Gas Chambers (MSGC) with a total number of 147 456 electronic read out channels. The detectors have to cope with particle fluxes up to 25 kHz/mm**2 and to…

Instrumentation and Detectors · Physics 2007-05-23 Bernhard Schmidt

We present results from further tests of Microstrip Gas Counters (MSGCs) with resistive electrodes. The maim advantage of this detector is that it is spark-protected: in contrast to "classical" MSGCs with metallic electrodes, sparks in this…

Instrumentation and Detectors · Physics 2011-01-20 R. Oliveira , V. Peskov , Pietropaolo , P. Picchi

We have developed a cost effective technology for manufacturing various layouts of micropattern gaseous detectors for a wide range of applications. Such devices feature resistive electrodes interfaced to a network of thin readout…

Instrumentation and Detectors · Physics 2015-06-15 V. Peskov , A. Di Mauroa , P. Fonte , P. Martinengo , E. Nappi , R. Oliveira , P. Pietropaolo , P. Picchi

Discrepancies between the measured and simulated gain in Thick Micropatterned gaseous detectors (MPGD), namely THGEM, have been observed by several groups. In order to simulate the electron avalanches and the gain the community relies on…

Instrumentation and Detectors · Physics 2016-09-21 C. D. R. Azevedo , P. M. Correia , L. F. N. D. Carramate , A. L. M. Silva , J. F. C. A. Veloso

In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the…

Instrumentation and Detectors · Physics 2015-06-26 R. Bellazzini , F. Angelini , L. Baldini , F. Bitti , A. Brez , L. Latronico , M. M. Massai , M. Minuti , N. Omodei , M. Razzano , C. Sgro , G. Spandre , E. Costa , P. Soffitta

Even though compressible plasma turbulence is encountered in many astrophysical phenomena, its effect is often not well understood. Furthermore, direct numerical simulations are typically not able to reach the extreme parameters of these…

Fluid Dynamics · Physics 2016-07-27 P. Grete , D. G. Vlaykov , W. Schmidt , D. R. G. Schleicher

Current radiation portal monitors at sea ports and international borders that employ standard radiation detection techniques are not very sensitive to nuclear contraband that is well shielded to absorb emanating radiation. Muon Tomography…

Instrumentation and Detectors · Physics 2016-11-17 M. Hohlmann , K. Gnanvo , L. Grasso , J. B. Locke , A. Quintero , D. Mitra

A comprehensive study, supported by systematic measurements and numerical computations, of the intrinsic limits of multi-GEM detectors when exposed to very high particle fluxes or operated at very large gains is presented. The observed…

‹ Prev 1 3 4 5 6 7 10 Next ›