English
Related papers

Related papers: Performance study of ASIC readout for electromagne…

200 papers

A prototype of a new type of calorimeter has been designed and constructed, based on a silicon-tungsten sampling design using pixel sensors with digital readout. It makes use of the Alpide MAPS sensor developed for the ALICE ITS upgrade. A…

For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM…

Operations typically used in machine learning al-gorithms (e.g. adds and soft max) can be implemented bycompact analog circuits. Analog Application-Specific Integrated Circuit (ASIC) designs that implement these algorithms using techniques…

Neural and Evolutionary Computing · Computer Science 2021-06-24 Shih-Chii Liu , John Paul Strachan , Arindam Basu

The SALSA chip is a future readout ASIC foreseen for the MPGD detectors, developed in the framework of the EIC collider project, to equip the MPGD trackers of the EPIC experiment. It is designed to be versatile, to be adapted to other…

ALICE (A Large Ion Collider Experiment) at the LHC is designed for studies of nuclear matter at extreme temperatures and energy densities, so called Quark-Gluon Plasma (QGP). Two detectors for measurements of electromagnetic signals,…

High Energy Physics - Experiment · Physics 2020-04-22 D. Blau

The DarkSHINE experiment aims to search for dark photons by measuring the energy loss of the electrons recoiled from fixed-target. Its electromagnetic calorimeter is primarily responsible for accurately reconstructing the energy of the…

Instrumentation and Detectors · Physics 2024-07-31 Yihan Guo , Shu Li , Kun Liu , Yang Liu , Yongqi Tan , Jiannan Tang , Weihao Wu , Haijun Yang , Zhiyu Zhao , Wei Zhi , Zhizhen Zhou

Within the CALICE collaboration, several concepts for the hadronic calorimeter of a future linear collider detector are studied. After having demonstrated the capabilities of the measurement methods in "physics prototypes", the focus now…

Instrumentation and Detectors · Physics 2019-04-26 Christian Graf

We develop the vertex detector for the international linear collider (ILC) using the FPCCD (Fine Pixel CCD), whose pixel size is 5 x 5 um2. Together with the FPCCD sensor, a prototype of the readout ASIC was developed in 2008. The readout…

Instrumentation and Detectors · Physics 2009-01-23 Yosuke Takubo , Hirokazu Ikeda , Kennosuke Itagaki , Akiya Miyamoto , Tadashi Nagamine , Yasuhiro Sugimoto , Hitoshi Yamamoto

Precision physics at future colliders requires highly granular calorimeters to support the Particle Flow Approach for event reconstruction. This article presents a review of about 10 - 15 years of R\&D, mainly conducted within the CALICE…

Instrumentation and Detectors · Physics 2016-04-20 Felix Sefkow , Andy White , Kiyotomo Kawagoe , Roman Pöschl , José Repond

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…

Instrumentation and Detectors · Physics 2008-11-26 Andre Sopczak

The CALICE collaboration is preparing large scale prototypes for highly granular calorimeters for detectors to be operated at a future linear electron positron collider. Currently a prototype of a SiW electromagnetic calorimeter is…

Instrumentation and Detectors · Physics 2019-08-13 Roman Pöschl

A new TDC chip has been developed for the COMPASS experiment at CERN. The resulting ASIC offers an unprecedented degree of flexibility and functionality. Its capability to handle highest hit and trigger input rates as well as its low power…

High Energy Physics - Experiment · Physics 2007-05-23 G. Braun , H. Fischer , J. Franz , A. Grunemaier , F. H. Heinsius , L. Hennig , K. Konigsmann , M. Niebuhr , M. Schierloh , T. Schmidt , H. Schmitt , H. J. Urban

The longitudinal segmentation of shashlik calorimeters is challenged by dead zones and non-uniformities introduced by the light collection and readout system. This limitation can be overcome by direct fiber-photosensor coupling, avoiding…

The measurement of the biological tissue's electrical impedance is an active research field that has attracted a lot of attention during the last decades. Bio-impedances are closely related to a large variety of physiological conditions;…

Emerging Technologies · Computer Science 2015-07-14 Saul Rodriguez , Stig Ollmar , Muhammad Waqar , Ana Rusu

Hybrid ECAL is a cost-conscious option of electromagnetic calorimeter (ECAL) for particle flow calorimetry to be used in a detector of International Linear Collider (ILC). It is a combination of silicon-tungsten ECAL, which realizes high…

Instrumentation and Detectors · Physics 2015-03-31 T. Suehara , H. Hirai , H. Sumida , H. Ueno , Y. Sudo , T. Yoshioka , K. Kawagoe

We demonstrate the design of an integrated conditional quantum teleportation circuit and a readout circuit using a two-dimensional photonic crystal single chip. Fabrication and testing of the proposed quantum circuit can be accomplished…

Quantum Physics · Physics 2015-06-26 Durdu Ö. Güney , David A. Meyer

We compared the performance of a commercial ammeter and a home-made integrating electrometer in reading ionisation chamber currents less than 100 pA. The integrating electrometer charges a capacitor with the unknown current and measures the…

Instrumentation and Detectors · Physics 2019-03-08 Stephen P. Giblin , Giuseppe Lorusso

We describe an algorithm which has been developed to extract fine granularity information from an electromagnetic calorimeter with strip-based readout. Such a calorimeter, based on scintillator strips, is being developed to apply particle…

Instrumentation and Detectors · Physics 2015-06-09 Katsushige Kotera , Daniel Jeans , Akiya Miyamoto , Tohru Takeshita

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling…

Instrumentation and Detectors · Physics 2012-08-08 C. Adloff , J. Blaha , J. -J. Blaising , C. Drancourt , A. Espargilière , R. Gaglione , N. Geffroy , Y. Karyotakis , J. Prast , G. Vouters , K. Francis , J. Repond , J. Smith , L. Xia , E. Baldolemar , J. Li , S. T. Park , M. Sosebee , A. P. White , J. Yu , Y. Mikami , N. K. Watson T. Goto , G. Mavromanolakis , M. A. Thomson , D. R. Ward W. Yan , M. Benyamna , C. Cârloganu , F. Fehr , P. Gay , S. Manen , L. Royer , G. C. Blazey , A. Dyshkant , J. G. R. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , U. Cornett , D. David , R. Fabbri , G. Falley , K. Gadow , E. Garutti , P. Göttlicher , C. Günter , S. Karstensen , F. Krivan , A. -I. Lucaci-Timoce , S. Lu , B. Lutz , I. Marchesini , N. Meyer , S. Morozov , V. Morgunov , M. Reinecke , F. Sefkow , P. Smirnov , M. Terwort , A. Vargas-Trevino , N. Wattimena , O. Wendt , N. Feege , J. Haller , S. Richter , J. Samson P. Eckert , A. Kaplan , H. -Ch. Schultz-Coulon , W. Shen , R. Stamen , A. Tadday , B. Bilki , E. Norbeck , Y. Onel , G. W. Wilson , K. Kawagoe , S. Uozumi , J. A. Ballin , P. D. Dauncey , A. -M. Magnan , H. S. Yilmaz , O. Zorba , V. Bartsch , M. Postranecky , M. Warren , M. Wing , F. Salvatore , E. Calvo Alamillo , M. -C. Fouz , J. Puerta-Pelayo , V. Balagura , B. Bobchenko , M. Chadeeva , M. Danilov , A. Epifantsev , O. Markin , R. Mizuk , E. Novikov , V. Rusinov , E. Tarkovsky , Y. Soloviev , V. Kozlov , P. Buzhan , B. Dolgoshein , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , S. Smirnov , A. Frey , C. Kiesling , K. Seidel , F. Simon , C. Soldner , L. Weuste , J. Bonis , B. Bouquet , S. Callier , P. Cornebise , Ph. Doublet , F. Dulucq , M. Faucci Giannelli , J. Fleury , G. Guilhem , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Pöschl , L. Raux , N. Seguin-Moreau , F. Wicek , M. Anduze , V. Boudry , J-C. Brient , D. Jeans , P. Mora de Freitas , G. Musat , M. Reinhard , M. Ruan , H. Videau , B. Bulanek , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , D. Lednicky , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , H. Ghazlane , K. Kotera , M. Nishiyama , T. Takeshita , S. Tozuka , T. Buanes , G. Eigen

The performance of prototypes for the ALICE electromagnetic sampling calorimeter has been studied in test beam measurements at FNAL and CERN. A $4\times4$ array of final design modules showed an energy resolution of about 11%…

Instrumentation and Detectors · Physics 2012-08-27 The ALICE EMCal group