English
Related papers

Related papers: Performance study of ASIC readout for electromagne…

200 papers

The electromagnetic calorimeter (ECAL) is a key detector component for precise electron and photon measurements in electron-ion collision experiments. At the Electron-Ion Collider in China (EicC), high-performance calorimetry is essential…

Instrumentation and Detectors · Physics 2026-03-23 Ye Tian , Souvik Maity , Jingyu Li , Yuancai Wu , Shan Sha , Yutie Liang , Aiqiang Guo , Yuxiang Zhao , Dexu Lin

Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride…

A 64-channel mixed-mode ASIC, suitable for particle detectors of large dynamic range and high capacitance up to hundreds of pF, is presented here. Each channel features an analogue front-end for signal amplification and filtering, and a…

Instrumentation and Detectors · Physics 2019-09-04 W. Cheng , F. Cossio , M. Da Rocha Rolo , A. Rivetti , Z. Wang

We present the first physical realization of in-pixel signal processing with integrated AI-based data filtering for particle tracking detectors. Building on prior work that demonstrated a physics-motivated edge-AI algorithm suitable for…

This paper presents performance measurements of a new readout electronics system based on silicon photomultipliers for the PHENIX electromagnetic calorimeter. Installation of the lead-scintillator Shashlik style calorimeter into the…

Various chips for the silicon sensors measurements are described. These chips are based on 0.35 um and 0.18um CMOS technology. Several analog chips together with self-trigger /derandomizer one allow to measure silicon sensors designed for…

Instrumentation and Detectors · Physics 2009-10-13 E. Atkin , A. Kluev , A. Silaev , A. Fedenko , D. Karmanov , M. Merkin , A. Voronin

The CALICE collaboration is currently developing an engineering prototype of an analog hadron calorimeter for a future linear collider like the ILC. One main task of this prototype is to demonstrate the feasibility of building a realistic…

Instrumentation and Detectors · Physics 2019-08-14 Benjamin Hermberg

We present the design and performance of a prototype ASIC digitizer for integrated wire chamber readout, implemented in 65 nm commercial CMOS technology. Each channel of the 4-channel prototype is composed of two 16-bit Time-to-Digital…

A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL for International Large Detector (ILD) concept, one of the two detector concepts for the detector(s) at the future International…

Instrumentation and Detectors · Physics 2020-04-28 Adrian Irles

The Advanced X-ray Imaging Satellite (AXIS) is a NASA probe class mission concept designed to deliver arcsecond resolution with an effective area ten times that of Chandra (at launch). The AXIS focal plane features an MIT Lincoln Laboratory…

A new design of highly granular hadronic calorimeter using Glass Resistive Plate Chambers (GRPCs) with embedded electronics has been proposed for the future International Linear Collider (ILC) experiments. It features a 2-bit threshold…

The successful realization of the EIC scientific program requires the design and construction of high-performance particle detectors. Recent developments in the field of scientific computing and increased availability of high performance…

Instrumentation and Detectors · Physics 2024-05-28 J. Crafts , R. Fatemi , T. Horn , D. Kalinkin

The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope…

We summarize recent R&D progress for a silicon-tungsten electromagnetic calorimeter (ECal) with integrated electronics, designed to meet the ILC physics requirements.

Instrumentation and Detectors · Physics 2009-02-16 R. Frey , J. Brau , M. Breidenbach , D. Freytag , G. Haller , R. Herbst , R. Lander , T. Nelson , V. Radeka , D. Strom , M. Tripathi

The CALICE collaboration is currently developing engineering prototypes of electromagnetic and hadronic calorimeters for a future linear collider detector. This detector is designed to be used in particle-flow based event reconstruction. In…

Instrumentation and Detectors · Physics 2019-08-13 Mark Terwort

Modern PET scanners based on scintillating crystals use solid state photo detectors for light readout. The small area of these devices is beneficial for spatial resolution, but also leads to a large number of electronic channels to be read…

Instrumentation and Detectors · Physics 2024-12-04 Peter Fischer , Michael Ritzert , Thomas Kerschenbauer

A basic prototype for an analog hadron calorimeter for a future linear collider detector is currently being realized by the CALICE collaboration. The aim is to show the feasibility to build a realistic detector with fully integrated readout…

Instrumentation and Detectors · Physics 2019-08-14 Mark Terwort

An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new…

This paper describes an R&D electronic program for the next generation of linear collider electromagnetic calorimeter. After a brief presentation of the requirements, a global scheme of the electronics is given. Then, we describe the three…

Instrumentation and Detectors · Physics 2007-05-23 S. Manen , G. Bohner , J. Lecoq , J. Fleury , C. De la Taille , G. Martin , the FLC Collaboration

An extended version of the CALICE silicon-tungsten ECAL was tested in November 2021 at the DESY beam test facility. With 15 active layers, it featured some with a thin PCB design, and a new compact DAQ system handling all layers in a common…

High Energy Physics - Experiment · Physics 2023-04-28 Vincent Boudry