English
Related papers

Related papers: Development of Single- and Double-sided Ladders fo…

200 papers

For the HERA upgrade, the ZEUS experiment has designed and installed a high precision Micro Vertex Detector (MVD) using single sided micro-strip sensors with capacitive charge division. The sensors have a readout pitch of 120 microns, with…

The Inert Doublet Model (IDM) is a simple extension of the Standard Model, introducing an additional Higgs doublet that brings in four new scalar particles. The lightest of the IDM scalars is stable and is a good candidate for a dark matter…

High Energy Physics - Phenomenology · Physics 2022-11-01 Jan Klamka , Aleksander Filip Zarnecki

The Silicon Pixel Detector (SPD) constitutes the two innermost layers of the Inner Tracking System of the ALICE experiment and it is the closest detector to the interaction point. As a vertex detector, it has the unique feature of…

Instrumentation and Detectors · Physics 2019-08-14 A. Mastroserio

To cope with the harsh environment foreseen at the high luminosity conditions of HL- LHC, the ATLAS pixel detector has to be upgraded to be fully efficient with a good granularity, a maximized geometrical acceptance and an high read out…

Under a smart grid paradigm, there has been an increase in sensor installations to enhance situational awareness. The measurements from these sensors can be leveraged for real-time monitoring, control, and protection. However, these…

Systems and Control · Electrical Eng. & Systems 2022-11-09 Shweta Dahale , Sai Munikoti , Balasubramaniam Natarajan , Rui Yang

During the LHC Long Shutdown 3 (2026-29) ALICE will replace its three innermost tracking layers by a new detector, the "ITS3". It will be based on newly developed, wafer-scale monolithic active pixel sensors, which are bent into truly…

Instrumentation and Detectors · Physics 2026-01-13 Jory Sonneveld

CMOS sensors were successfully implemented in the STAR tracker [1]. LHC experiments have shown that efficient b tagging, reconstruction of displaced vertices and identification of disappearing tracks are necessary. An improved vertex…

Instrumentation and Detectors · Physics 2021-05-21 Nicolas T. Fourches , Geraldine Hallais , Charles Renard

The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key…

This paper presents a study of vertex tracking with a beam hodoscope consisting of three layers of monolithic pixel sensors in SOI technology on high-resistivity substrate. We study the track extrapolation accuracy, two-track separation and…

Instrumentation and Detectors · Physics 2015-06-04 Marco Battaglia , Devis Contarato , Peter Denes , Dietrich Liko , Serena Mattiazzo , Devis Pantano

We present a method to improve the accuracy of a zero-velocity-aided inertial navigation system (INS) by replacing the standard zero-velocity detector with a long short-term memory (LSTM) neural network. While existing threshold-based…

Robotics · Computer Science 2019-08-14 Brandon Wagstaff , Jonathan Kelly

To achieve lightweight object detectors for deployment on the edge devices, an effective model compression pipeline is proposed in this paper. The compression pipeline consists of automatic channel pruning for the backbone, fixed channel…

Computer Vision and Pattern Recognition · Computer Science 2019-05-07 Yiwu Yao , Weiqiang Yang , Haoqi Zhu

The MAPS technology is considered as a possible choice for the ILC Vertex Detector. Test results of MIMOSA-5 sensors indicate that the pixel multiplicity and the single point resolution depend significantly on the incident particle angle.…

Instrumentation and Detectors · Physics 2009-02-19 L. Maczewski , P. Niezurawski , A. F. Zarnecki , M. Adamus , J. Ciborowski

This paper describes a comprehensive experimental study on viability and prospects for the measurement of electroweak observables in $e^{+}e^{-}\rightarrow b\bar{b}$ and $e^{+}e^{-}\rightarrow c\bar{c}$ processes at the International Linear…

High Energy Physics - Experiment · Physics 2023-12-20 A. Irles , R. Pöschl , F. Richard

This paper reports on the design optimization done for Double Sided silicon microStrip Detectors(DSSDs) to reduce the Equivalent Noise Charge (ENC) and to maximize the breakdown voltage and Charge Collection Efficiency. Various isolation…

Instrumentation and Detectors · Physics 2015-06-12 S. Chatterji , M. Singla , W. F. J. Mueller , J. M. Heuser

We discuss the design considerations and initial measurements from arrays of dual-polarization, lumped element kinetic inductance detectors (LEKIDs) nominally designed for cosmic microwave background (CMB) studies. The detectors are…

The prevalent approaches of unsupervised 3D object detection follow cluster-based pseudo-label generation and iterative self-training processes. However, the challenge arises due to the sparsity of LiDAR scans, which leads to pseudo-labels…

Computer Vision and Pattern Recognition · Computer Science 2024-06-27 Hai Wu , Shijia Zhao , Xun Huang , Chenglu Wen , Xin Li , Cheng Wang

The International Large Detector (ILD) is a concept for a detector at the International Linear Collider, ILC. The ILC will collide electrons and positrons at energies of initially 500 GeV, upgradeable to 1 TeV. The ILC has an ambitious…

High Energy Physics - Experiment · Physics 2012-08-27 The ILD Concept Group

For large scale applications, hybrid pixel detectors, in which sensor and read-out IC are separate entities, constitute the state of the art in pixel detector technology to date. They have been developed and start to be used as tracking…

Instrumentation and Detectors · Physics 2010-01-22 Norbert Wermes

DEPleted Field Effect Transistor (DEPFET) active pixel detectors combine a first amplification stage with a fully depleted sensor in one single device, resulting in a very good signal-to-noise ratio even for thin sensors. DEPFET pixels are…

Instrumentation and Detectors · Physics 2010-10-19 P. Vazquez

The precision physics program of the ILC requires precise knowledge of the state of beam polarisation. In fact the Compton polarimeters intended for the ILC will have to measure the polarisation with error a factor of 2 smaller than the…

Instrumentation and Detectors · Physics 2014-11-20 Christoph Bartels , Anthony Hartin , Christian Helebrant , Daniela Kaefer , Jenny List
‹ Prev 1 4 5 6 7 8 10 Next ›