Related papers: Electromagnetic cavity tests of Lorentz invariance…
We present a Michelson-Morley type experiment for testing the isotropy of the speed of light in vacuum and matter. The experiment compares the resonance frequency of a monolithic optical sapphire resonator with the resonance frequency of an…
We present an improved laboratory test of Lorentz invariance in electrodynamics by testing the isotropy of the speed of light. Our measurement compares the resonance frequencies of two orthogonal optical resonators that are implemented in a…
We demonstrate that Michelson-Morley tests, which detect direction-dependent anisotropies in the speed of light, can also be used to place limits upon isotropic deviations of the vacuum speed of light from $c$, as described by the photon…
We report on a new test of Lorentz invariance performed by comparing the resonance frequencies of two orthogonal cryogenic optical resonators subject to Earth's rotation over 1 year. For a possible anisotropy of the speed of light c, we…
A test of Lorentz invariance for electromagnetic waves was performed by comparing the resonance frequencies of two stable optical resonators as a function of orientation in space. The crystalline resonators were operated at 3.4 K in a…
We present the first results from a rotating Michelson-Morley experiment that uses two orthogonally orientated cryogenic sapphire resonator-oscillators operating in whispering gallery modes near 10 GHz. The experiment is used to test for…
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its…
We report on a test of Lorentz invariance performed by comparing the resonance frequencies of one stationary optical resonator and one continuously rotating on a precision air bearing turntable. Special attention is paid to the control of…
We present a design for an ultra-stable cryogenically cooled sapphire optical cavity system, with fractional frequency stability better than 1 x 10^-16 at one second integration time. We plan to use such ultra-stable cavities to perform a…
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its…
We have developed an apparatus to search for the higher-order Lorentz violation in photons by measuring the resonant frequency difference between two counterpropagating directions of an asymmetric optical ring cavity. From the year-long…
We propose an interesting mechanism to reconcile the recent experiments of the Michelson-Morley type and slowdown of the velocity of light in dark matter with a fractional electric charge when the index of refraction of dark matter depends…
We report on a measurement of the constancy and anisotropy of the speed of light relative to the electrons in photon-electron scattering. We used the Compton scattering asymmetry measured by the new Compton polarimeter in Hall~C at…
Data from a new experiment measuring the anisotropy of the one-way speed of EM waves in a coaxial cable, gives the speed of light as 300,000+/-400+/-20km/s in a measured direction RA=5.5+/-2hrs, Dec=70+/-10deg S, is shown to be in excellent…
A test of Lorentz invariance for electromagnetic waves was performed by comparing the resonance frequencies of two optical resonators as a function of orientation in space. In terms of the Robertson-Mansouri-Sexl theory, we obtain…
We present the design and first measurement results for an ultra-stable cryogenically cooled optical sapphire resonator system with a potential relative frequency stability better than 3x10^-17. This level of oscillator stability allows for…
We consider tests of Lorentz invariance for the photon and fermion sector that use vacuum and matter-filled cavities. Assumptions on the wave-function of the electrons in crystals are eliminated from the underlying theory and accurate…
All evidence so far suggests that the absolute spatial orientation of an experiment never affects its outcome. This is reflected in the Standard Model of physics by requiring all particles and fields to be invariant under Lorentz…
We propose to study of the light speed isotropy and Lorentz invariance at Jefferson Laboratory by means of the measurements of the Compton Edge using of the Hall A/C existing experimental setup. Methodologically the same experiment has…
We report Relativity tests based on data from two simultaneous Michelson-Morley experiments, spanning a period of more than one year. Both were actively rotated on turntables. One (in Berlin, Germany) uses optical Fabry-Perot resonators…