Related papers: Arm-length stabilisation for interferometric gravi…
Arm locking is one of the key technologies to suppress the laser phase noise in spaced-based gravitational waves observatories. Since arm locking was proposed, phase margin criterion was always used as the fundamental design strategy for…
Laser frequency noise is a dominant noise background for the detection of gravitational waves using long-baseline optical interferometry. Amelioration of this noise requires near simultaneous strain measurements on more than one…
To achieve sub-picometer sensitivities in the millihertz band, laser interferometric inertial sensors rely on some form of reduction of the laser frequency noise, typically by locking the laser to a stable frequency reference, such as the…
We present detailed numerical simulations of a laser phase stabilization scheme for LISA, where both lasers emitting along one arm are locked to each other. Including the standard secondary noises and spacecraft motions that approximately…
In the detection of gravitational waves in space, the arm lengths between spacecraft are not equal due to their orbital motion. Consequently, the equal arm length Michelson interferometer used in Earth laboratories is not suitable for…
Frequency stabilisation of lasers to optical reference cavities is an established method to achieve state-of-the-art stability. The strengths of this method are the high discriminator coefficient of optical cavities, and the low-noise…
Length changes due to thermo-mechanical noise originating from, for example, Brownian motion are a key limiting factor of present day state-of-the-art laser frequency stabilization using Fabry-P\'erot cavities. We present a laser-frequency…
We propose a dual cavity Fabry-Perot interferometer as a wavelength calibrator and a stability tracking device for astronomical spectrograph. The FPI consists of two adjoining cavities engraved on a low expansion monoblock spacer. A…
Ultra-stable, quasi-monochromatic laser light forms the basis for high-precision interferometric measurements, e.g. for observing gravitational waves and for time keeping with optical clocks. Optical frequency conversion enables access to…
To obtain a high degree of long-term length stabilisation of an optical reference cavity, its free-spectral range is locked by means of an accurate and stable frequency synthesizer. The locking scheme is twofold: a laser is locked on the…
We give a simple introduction to the properties and use of ultrastable optical cavities, which are increasingly common in atomic and molecular physics laboratories for stabilizing the frequency of lasers to linewidths at the kHz level or…
The Advanced LIGO gravitational wave detectors are second generation instruments designed and built for the two LIGO observatories in Hanford, WA and Livingston, LA. The two instruments are identical in design, and are specialized versions…
We herein report a simultaneous frequency stabilization of two 780-nm external cavity diode lasers using a precision wavelength meter (WLM). The laser lock performance is characterized by the Allan deviation measurement in which we find…
State-of-the-art laser frequency stabilization is limited by miniscule length changes caused by thermal noise. In this work, a cavity-length-insensitive frequency stabilization scheme is implemented using strong dispersion in a…
We present a compact laser frequency stabilization method by locking a 556 nm laser to a high-precision wavelength meter. Unlike traditional schemes that rely on optical cavities or atomic references, we stabilize the laser frequency via a…
Astrophysical observations suggest the existence of an unknown kind of matter in the Universe, in the frame of the $\Lambda$CDM model. The research field of dark matter covers an energy scale going from massive objects to ultra-light scalar…
We present a new general design approach of a broad-band detector of gravitational radiation that relies on two atom interferometers separated by a distance L. In this scheme, only one arm and one laser will be used for operating the two…
A derivation of the optical axis lenght fluctations due by tilts of the mirrors of the Fabry-Perot cavity of long-baseline interferometers for the detection of gravitational waves in presence of the gravitational field of the earth is…
Current and future interferometeric gravitational-wave detectors are limited predominantly by shot noise at high frequencies. Shot noise is reduced by introducing arm cavities and signal recycling, however, there exists a tradeoff between…