Related papers: Characterization of proton irradiated 3D-DDTC pixe…
The LHC is expected to reach luminosities up to 3000fb-1 and the innermost layer of the ATLAS upgrade plans to cope with higher occupancy and to decrease the pixel size. 3D-Si sensors are a good candidate for the innermost layer of the…
After ten years of operation at the LHC, the planar pixel sensors of the innermost barrel layer of the ATLAS Pixel detector have accumulated an average bulk damage fluence in excess of $2\times10^{15}$ 1 MeV-neutrons equivalent/cm$^2$. The…
We report on the characterization by a position resolved laser system of small-pitch 3D diodes irradiated with neutrons up to an extremely high fluence of 3.5x10**16 neq cm**-2. We show that very high values of signal efficiency are…
The ATLAS Forward Proton (AFP) detector is intended to measure protons scattered at small angles from the ATLAS interaction point. To this end, a combination of 3D Silicon pixel tracking modules and Quartz-Cherenkov time-of-flight (ToF)…
We present an R&D activity focused on the development of novel modules for the upgrade of the ATLAS pixel system at the High Luminosity LHC (HL-LHC). The modules consist of n-in-p pixel sensors, 100 or 200 $\mu$m thick, produced at VTT…
The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. The vertex detector is located near the interaction point, thus high radiation tolerance is required. Charge transfer efficiency of CCD is…
3D silicon pixel detectors have been investigated as radiation-hard candidates for the innermost layers of the HL-LHC upgrade of the ATLAS pixel detector. 3D detectors are already in use today in the ATLAS IBL and AFP experiments. These are…
The performance of novel n-in-p planar pixel detectors, designed for future upgrades of the ATLAS Pixel system is presented. The n-in-p silicon sensors technology is a promising candidate for the pixel upgrade thanks to its radiation…
Following the Phase-II upgrade during Long Shutdown (LS3), the LHC aims to reach a peak instantaneous luminosity of $7.5\times 10^{34}$cm$^{-2}$s$^{-1}$, which corresponds to an average of around 200 inelastic proton-proton collisions per…
During the scheduled high luminosity upgrade of LHC, the world's largest particle physics accelerator at CERN, the position sensitive silicon detectors installed in the vertex and tracking part of the CMS experiment will face more intense…
In the high luminosity era of the Large Hadron Collider, the HL-LHC, the instantaneous luminosity is expected to reach unprecedented values, resulting in about 200 proton-proton interactions in a typical bunch crossing. To cope with the…
Charge collection measurements performed on heavily irradiated p-spray DOFZ pixel sensors with a grazing angle hadron beam provide a sensitive determination of the electric field within the detectors. The data are compared with a complete…
In order to evaluate the response to cosmic-ray nuclei of a Compton-Scatter Transition Radiation Detector in the proposed ACCESS space-based mission, a hybrid Monte Carlo simulation using GEANT3 and an external transition radiation (TR)…
We present the results of the characterization of novel n-in-p planar pixel detectors, designed for the future upgrades of the ATLAS pixel system. N-in-p silicon devices are a promising candidate to replace the n-in-n sensors thanks to…
The pixel detector is the innermost tracking device in CMS, reconstructing interaction vertices and charged particle trajectories. The sensors located in the innermost layers of the pixel detector must be upgraded for the ten-fold increase…
The ATLAS Forward Proton (AFP) detector is designed to identify events in which one or two protons emerge intact from the LHC collisions. AFP will consist of a tracking detector, to measure the momentum of the protons, and a time of flight…
Silicon photomultipliers (SiPMs) are highly-sensitive photodetectors emerging as the technology of choice for many applications, including large high-energy physics experiments where they often are exposed to high radiation fluences. In…
For the Phase-II Upgrade of the ATLAS detector at CERN, the current ATLAS Inner Detector will be replaced with the ATLAS Inner Tracker. The ATLAS Inner Tracker will be an all-silicon detector, consisting of a pixel tracker and a strip…
The ATLAS experiment at the LHC will replace its current inner tracker system for the HL-LHC era. 3D silicon pixel sensors are being considered as radiation-hard candidates for the innermost layers of the new fully silicon-based tracking…
A method is presented which allows to obtain the position-dependent electric field and charge density by fits to velocity profiles from edge-TCT data from silicon strip-detectors. The validity and the limitations of the method are…